Labshake search
Citations for Tosoh Bioscience :
1 - 15 of 15 citations for Glucose Fluorescent Detection Kit 2 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2023Quote: ... Samples were separated by HPLC with fluorescence detection on a TSKgel Amide-80 column (Tosoh Bioscience, Tokyo, Japan) with a linear gradient of a 50 mM ammonium formate/acetonitrile solvent system ...
-
bioRxiv - Microbiology 2019Quote: ... The 2AB-glycans were separated by HPLC with fluorescence detection (360 nm/425 nm) on a TSKgel Amide-80 column (Tosoh Bioscience, Japan), using a linear gradient of a 50mmol/L-ammonium formate/acetonitrile solvent system ...
-
bioRxiv - Plant Biology 2020Quote: ... a TSK gel ODS-80Ts column (2 mm × 250 mm, Tosoh) and a linear gradient program composed of 20% to 80% (v/v ...
-
bioRxiv - Plant Biology 2022Quote: ... TSK gel ODS-100V (2 mm ID x 150 mm, 3 µm, Tosoh, Tokyo, Japan). The column was eluted with a linear gradient from 30 to 90% mobile phase B (0.1% formic acid in acetonitrile ...
-
bioRxiv - Biophysics 2022Quote: ... 500 μL of protein solution was placed in a 2 mm path-length quartz cuvette (TOSOH, Japan), and spectra were collected in a continuous scanning mode from 260 to 200 nm wavelength ...
-
bioRxiv - Genetics 2020Quote: ... equipped with a TSKgel Amide-80 column (250 μm × 15 cm, 2 µm particle size, Tosoh Bioscience, Japan) and 23 fractions were collected.
-
bioRxiv - Bioengineering 2022Quote: ... 15 uL of each antibody at 2 mg/mL was injected into the TSKgel SuperSW mAb column (Tosoh) with the flow rate of 1 mL/min.
-
bioRxiv - Developmental Biology 2021Quote: ... Samples were fractionated using a TSK gel Amide-80 column (2 mm x 150 mm, 5 μm; Tosoh Bioscience), using a three-solvent system ...
-
bioRxiv - Molecular Biology 2020Quote: ... 80 μL of the reconstituted sample was injected and fractionated by hydrophilic interaction liquid chromatography (HILIC) using a TSK gel Amide-80 column (2 mm x 150 mm, 5 μm; Tosoh Bioscience). Three solvents were used for the gradient ...
-
bioRxiv - Biochemistry 2019Quote: ... reconstituted in 80% acetonitrile and 1% formic acid and fractionated by hydrophilic interaction liquid chromatography (HILIC) with TSK gel Amide-80 column (2 mm x 150 mm, 5 µm; Tosoh Bioscience). 90sec fractions were collected between 10 and 25 min of the gradient ...
-
bioRxiv - Biophysics 2020Quote: ... The di-nucleosome DNA with the modified 5S rRNA gene cassettes (X5S 217F-2) was excised with PvuII and purified by ion-exchange chromatography on a TSK-gel DEAE-5PW column (Tosoh Corporation). In the naked DNA transcription assay ...
-
bioRxiv - Cell Biology 2023Quote: ... HILIC fractionation of the peptides was performed using a TSK-Gel amide-80 3UM 2 × 150 mm SILICA HPLC column (Tosoh Bioscience) connected to a 1290 Infinity Binary LC system from Agilent Technologies (Santa Clara) ...
-
bioRxiv - Molecular Biology 2023Quote: ... Glycopeptides of hAGP tryptic digest were then captured using an Amide-80 column (TSK-gel Amide-80, 2 × 50 mm; TOSOH, Tokyo, Japan) equilibrated with 75% acetonitrile (Merck ...
-
bioRxiv - Molecular Biology 2022Quote: ... Serum progesterone levels were measured using an enzyme immunoassay kit (TOSOH, Tokyo, Japan), and ovulation was defined the day before the serum progesterone concentration exceeded 10 ng/mL.
-
bioRxiv - Physiology 2021Quote: ... Plasma insulin concentrations were determined using a commercial immunoassay kit (ST AIA-PACK IRI) and the AIA-1800 device (Automated Immunoassay Analyzer; TOSOH Bioscience, Tokyo, Japan). Assay sensitivity was 0.5 µUI/ml and the intra-assay CV was below 5% ...