Labshake search
Citations for NanoTemper :
1 - 12 of 12 citations for 5 Sulfosalicylaldehyde sodium salt since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2021Quote: ... MBP-PDF2(START)L467P were labeled in 50 mM sodium phosphate buffer (pH 7.4) supplemented with 500 mM NaCl using Monolith Protein Labeling kit RED-MALEIMIDE (NanoTemper) according to manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2021Quote: ... 20 µL reactions were incubated at room temperature for 5 min and 5 µL of the mixture was loaded into NT.115 capillaries (NanoTemper). MST was performed in Monolith NT.115 (NanoTemper ...
-
bioRxiv - Biochemistry 2023Quote: ... centrifuged for 5 min and loaded to standard capillaries (Nanotemper, #MO-K022). To investigate competitive effects of different ligands ...
-
bioRxiv - Molecular Biology 2021Quote: ... between protein:compound sample and a protein only sample at 1.5-2-5 sec is calculated and plotted through MO.Affinity analysis v2.3 (NanoTemper Technologies) and GraphPad Prism 8.0.0 (GraphPad Software ...
-
bioRxiv - Biochemistry 2022Quote: ... Measurements were done in triplicate at multiple concentrations (50 µM, 5 µM, and 0.5 µM) in Tycho standard capillaries (Nanotemper Technologies). Data analysis was performed via MO Affinity Analysis Software v2.1.3 (Nanotemper Technologies ...
-
bioRxiv - Microbiology 2023Quote: ... around 5 μl of the samples were loaded in MonolithTM Capillaries and MST analysis was carried out on the Instrument (Nanotemper).
-
bioRxiv - Biochemistry 2020Quote: ... Reaction mixtures were incubated for 15 min at 25°C and approximately 5 µL of solution was loaded into Monolith NT Standard Capillaries (NanoTemper Technologies). Measurements were performed at 25°C using 20% LED and 20% IR-laser power with 5 s/30 s/5 s laser off/on/off times ...
-
bioRxiv - Biochemistry 2022Quote: Protein melting profiles using 5 μM of 4B7- or 1245-Db were measured with Tycho NT.6 (NanoTemper® Technologies GmbH). Fluorescence emission intensities was measured at I350 and I330 in triplicates and its ratio plotted as a function of temperature ...
-
bioRxiv - Microbiology 2022Quote: Purified WT or mutant NSP12 recombinant proteins were labeled with Cytidine-5 dye using the Monolith His-Tag labeling kit (NanoTemper Technologies), and then labeled NSP12 proteins were diluted to 700 nM in PBST buffer ...
-
bioRxiv - Molecular Biology 2023Quote: ... selected linear/circular aptamers were equally diluted with 5’ Cy5 labeled complementary strand to reach the optimum concentrations of 5 nM where satisfying fluorescence intensity was obtained for KD determination using Monolith device (NanoTemper, Germany). Affinity of the selected aptamers was evaluated in 16 test tubes where spike/RBD proteins were diluted by double from the initial concentration 1 mM and then 5 nM of aptamer/Cy5 labeled complementary strand complex were added to each protein dilution in final volume of 20 μl ...
-
bioRxiv - Biochemistry 2023Quote: ... and centrifuged at 20k ×g at 4 °C for 5 min prior to loading into standard-coated capillary tubes (NanoTemper, GmbH, Munich, Germany). Microscale thermophoresis data were collected on a Monolith NT.115 (NanoTemper ...
-
bioRxiv - Biochemistry 2023Quote: ... MnCl2 and DTT were added just before the experiment) and incubated at RT for 5 min before samples were loaded with premium capillaries (NanoTemper Technologies, cat. no. MO-K025). Data were recorded sequentially at 40% ...