Labshake search
Citations for MicroSolv :
1 - 19 of 19 citations since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2024Quote: ... differentiation and detection of each metabolite were performed with an Agilent Accurate Mass 6230 TOF coupled with an Agilent 1290 Liquid Chromatography system using a Cogent Diamond Hydride Type C column (Microsolv Technologies, Long Branch, NJ, USA) with solvents and configuration as previously described.40,48 An isocratic pump was used for continuous infusion of a reference mass solution to allow mass axis calibration ...
-
bioRxiv - Biochemistry 2024Quote: ... ions were separated using a Cogent Diamond Hydride HILIC chromatography column (2.2 µM, 120 Å, 150 mm x 2.1 mm, MicroSolv Leland, NC, United States) at a flow rate of 0.400 uL/min.
-
bioRxiv - Biochemistry 2024Quote: ... Ions were separated using a Cogent Diamond Hydride HILIC chromatography column (2.2 µM, 120 Å, 150 mm x 2.1 mm, MicroSolv Leland, NC, United States) at a flow rate of 0.400 uL/min ...
-
bioRxiv - Bioengineering 2024Quote: ... Separation of metabolites occurred on a Cogent Diamond Hydride HILIC column (150 x 2.1 mm, MicroSolv, Eatontown, NJ) using an optimized normal phase 25-minute gradient elution method21.
-
bioRxiv - Microbiology 2024Quote: ... and the resulting supernatant (15-25µL) was transferred to glass vials (Microsolv 9532S-3CP-RS). In cases of large sample volumes ...
-
bioRxiv - Microbiology 2024Quote: ... and 30 µL of each sample was transferred to vials (MicroSolv 2 mL vials with AQ Brand deactivated glass low volume inserts ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... All samples were filtered (0.22 µm hydrophobic PTFE filter, MicroSolv) and stored at 4°C in the dark until LC-ICPMS and LC-ESI-QTOFMS analyses.
-
bioRxiv - Systems Biology 2023Quote: ... 10 μL of extract was separated on an Agilent 1290 Infinity LC system containing a Cogent Diamond Hydride Type C silica column (150 mm × 2.1 mm; Microsolv Technologies). Acquisition was performed on an Agilent 6230 TOF mass spectrometer (Agilent Technologies ...
-
bioRxiv - Molecular Biology 2023Quote: ... The purity of final products was assessed using an Agilent Technologies 1260 Infinity II LC at 220 nm UV absorption (Waters XBridge BEH C18 2.1 × 50 mm, 2.5 µm) or an Agilent Technologies 385-ELSD (Microsolv Cogent 2.0 Bidentate C18 2.1 × 50 mm ...
-
bioRxiv - Biochemistry 2023Quote: ... streptavidin enrichment and tryptic digestion were performed as previously described.58 Peptides (25 μL) were transferred to 200 μL volume AQ brand silanized glass vial inserts in 2 mL glass autosampler vials (MicroSolv) and stored at −20 °C.
-
bioRxiv - Microbiology 2022Quote: ... 185-200 µL of the supernatant was transferred to an RSA autosampler vial (Microsolv Technology Corporation, Leland, NC) for immediate analysis or frozen at -70°C until analysis.
-
bioRxiv - Cell Biology 2022Quote: ... A Cogent Diamond Hydride HIILIC chromatography column was utilized (2.2 μM, 120 Å, 150 mm x 2.1 mm, MicroSolv Leland, NC, United States). 5 μL of sample was injected and blank samples were analyzed every 7-10 samples for quality control to prevent spectral drift and contamination ...
-
bioRxiv - Microbiology 2022Quote: ... samples were separated on a Cogent Diamond Hydride Type C column (Microsolv Technologies). The mobile phase consisted of solvent A (ddH2O with 0.2% formic acid ...
-
bioRxiv - Biochemistry 2022Quote: ... Metabolites were separated on a Cogent Diamond Hydride HILIC column (150 × 2.1 mm, MicroSolv, Eatontown, NJ) using an optimized normal phase 25-minute gradient elution method(12-14) ...
-
bioRxiv - Biochemistry 2021Quote: ... Electrospray LC-MS/MS was performed on the LTQ XL using a Cogent 4 diamond hydride column (15 cm x 1 mm; Microsolv Technology, 70000-15P-1) eluted at 50 μl min ...
-
bioRxiv - Pathology 2021Quote: ... The chromatography used a Cogent Diamond Hydride HILIC 150 x 2.1 mm column (MicroSolv, Eatontown, NJ, USA) in normal phase with established elution methods[19] ...
-
bioRxiv - Immunology 2020Quote: ... The chromatographic run used a Cogent Diamond Hydride HILIC 150 × 2.1 mm column (MicroSolv, Eatontown, NJ) in normal phase with our established elution methods[26] ...
-
bioRxiv - Bioengineering 2020Quote: ... sealed with 20-mm Crimp Cap (95025-01-1S, MicroSolv). Then all the vials were transferred into an anaerobic chamber ...
-
bioRxiv - Physiology 2020Quote: ... 4 μm Diamond Hydride silica column (Microsolv Technologies, NJ, USA) and a linear gradient from 65% buffer B (0.1% formic acid in Acetronitrile ...