1 - 20 of 20 citations for Recombinant Human FCGRT & B2M Protein His Strep II tagged Biotinylated since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2020Quote: ... samples containing 100 ng recombinant protein were run over a 5 μm Jupiter C4 300Å LC column (Phenomenex, Torrance, California) using the 1260 Infinity LC system (Agilent Technologies ...
-
bioRxiv - Microbiology 2022Quote: ... Basic reversed phase fractionation was performed on a quaternary Agilent 1290 Infinity II UPLC system equipped with a Kinetex Evo-C18 column (150 × 2.1 mm, 2.6µm, 100 Å, Phenomenex) that was operated at 40°C ...
-
bioRxiv - Microbiology 2022Quote: compounds were separated using an Agilent 1290 Infinity II UPLC equipped with a Kinetex C18 column (1.7 µm, 2.1 × 100 mm, Phenomenex) and detected using an Agilent 6530 Q-TOF equipped with a dual Agilent jet stream electrospray ionization (AJS-ESI ...
-
bioRxiv - Physiology 2022Quote: Method (II)—lipid mediators—was performed using a Kinetex C8 (2.6 μm, 150 mm x 2.1 mm, Phenomenex) column at 40 °C ...
-
bioRxiv - Immunology 2022Quote: ... and fractionated using basic reversed phase fractionation on a quaternary Agilent 1290 Infinity II UPLC system equipped with a Kinetex Evo-C18 column (150 x 2.1 mm, 2.6µm, 100 Å, Phenomenex). Fractions were concatenated into 8 final samples ...
-
bioRxiv - Biophysics 2021Quote: The purified proteins were analyzed using BioSep SEC-s4000 (Phenomenex) particle size 5 μm ...
-
bioRxiv - Systems Biology 2023Quote: ... The MW was estimated using a protein mixture (Phenomenex AL03042), while a E.Coli 70s ribosome (NEB ...
-
bioRxiv - Microbiology 2019Quote: Biological extracts were pooled (1mg/mL) and run on a Bruker Impact II qTOF with a C18 UPLC (Phenomenex) in two technical replicates ...
-
bioRxiv - Microbiology 2023Quote: Protein samples were injected onto a Yarra 3 µm SEC-2000 (Phenomenex) running at room temperature in 150 mM NaCl ...
-
bioRxiv - Biophysics 2019Quote: ... The labeled protein was recovered on an S-2000 column (Phenomenex Biosep-SEC-S-2000) equilibrated in 50% MeOH and its mass confirmed by ESI-MS (PSC ...
-
bioRxiv - Cell Biology 2020Quote: ... Protein free supernatants were then injected into a Hypersil 3-μm ODS-C18 column (Phenomenex, USA) and eluted at 0.5 mL/min with a mobile phase consisting of 9% (v/v ...
-
bioRxiv - Microbiology 2023Quote: ... the activity of DisA was further confirmed by LC-MS (ESI-TOF mass spectrometer; MicrO-TOF II, Bruker) connected to Ultimate 3000 HPLC system (Dionex) on C18 column (Phenomenex, 150×4.6 mm, 110 Å, 5 μm) and using a flow rate of 0.2 mL/min and a 45 min program (for 5 min ...
-
bioRxiv - Systems Biology 2019Quote: ... Soluble protein (1.25 mg, 250 μL) was applied to a BioSep-SEC-s4000 gel filtration column (Phenomenex) equilibrated in PBS ...
-
bioRxiv - Systems Biology 2020Quote: ... Soluble protein (250 μL, 2 mg/mL) was applied to a BioSep-SEC-s4000 gel filtration column (Phenomenex) equilibrated in PBS ...
-
bioRxiv - Immunology 2022Quote: Trypsin-digested 6-Helix protein was then purified by high-pressure liquid chromatography (HPLC) on a C18 semi-preparative column (Phenomenex) over a 38-45% acetonitrile gradient in the presence of 0.1% trifluoroacetic acid ...
-
bioRxiv - Immunology 2023Quote: ... Aliquots of 100µL of plasma and tissue lysates were added to a protein precipitation plate (CE0-7565-R, Phenomenex, USA) along with 200µL of cold acetonitrile containing the deuterated internal standards ...
-
bioRxiv - Cell Biology 2020Quote: The digested proteins were desalted by running on a Strata X C18 SPE column (Catalog No. 8B-S100-AAK, Phenomenex, Torrance, CA) and then vacuum-dried ...
-
bioRxiv - Systems Biology 2022Quote: The molecular weight calibration curve for SEC fractionation was obtained by running a protein standard mix (Column Performance Check Standard, Aqueous SEC 1, AL0-3042, Phenomenex, CA, USA) before each sample injection (Supplementary Table 19).
-
bioRxiv - Biochemistry 2019Quote: ... formic acid in LC-Grade MeOH (in P3) is transferred into the all wells (in P4) of the 96-well IMPACT® protein precipitation plate (Phenomenex®) fitted onto a square 96-well (2ml ...
-
bioRxiv - Plant Biology 2023Quote: ... Aliquots of 10 µL aliquotof protein extracts were transferredinto two 96-well plates (Strata 96-wellcollection plate, 350 µL conical polypropylene, Phenomenex, Lane Cove, NSW, Australia), diluted 6 times with 50 mM ammonium bicarbonate and digested with 5 µL aliquots of the trypsin/Lys-C solution prepared earlier ...