Labshake search
Citations for Phenomenex :
1 - 21 of 21 citations for 6 9 Diaza spiro 4.5 decane 2HCl since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2019Quote: ... 250 9 4.60 mm column (Phenomenex, Torrance, CA, USA) and an LC-4C electrochemical detector with glassy carbon electrode (BAS) ...
-
bioRxiv - Microbiology 2021Quote: ... DPA was separated and eluted using gradient chromatography over a Kinetex 2.6 μm EVO C18 100Å LC column (150 x 4.5 mm; Phenomenex, USA) fitted with a guard column ...
-
bioRxiv - Microbiology 2021Quote: ... DPA was measured using HPLC fluorescence and DPA separation was performed using a Kinetex 2.6 μm EVO C18 100 Å LC column (150 × 4.5 mm, Phenomenex, USA) fitted with a guard column connected to a Thermo RS3000 pump ...
-
bioRxiv - Biochemistry 2021Quote: ... The separation was performed on the C18 column Luna 5 μm (2) 100 A 250 x 4.5 mm (Phenomenex Inc., Torrance, CA, USA).
-
bioRxiv - Bioengineering 2022Quote: ... the supernatant was filtered (0.22 μm, syringe filter) and transferred into HPLC vials (VVial, clear, 9 mm, screw, Phenomenex). Extracellular metabolites were measured using high-performance liquid chromatography (HPLC ...
-
bioRxiv - Bioengineering 2022Quote: ... 200 μL of the lower organic phase were transferred into a glass vial (VVial, clear, 9 mm, screw, Phenomenex) containing an insert (15 mm tip ...
-
bioRxiv - Biochemistry 2021Quote: ... Peptide samples were pressure-loaded onto 100 µm fused silica microcapillary columns packed first with 9 cm of reverse phase material (Aqua; Phenomenex), followed by 3 cm of 5-μm Strong Cation Exchange material (Luna ...
-
bioRxiv - Biochemistry 2020Quote: ... Peptide samples were pressure-loaded onto 100 µm fused silica microcapillary columns packed first with 9 cm of reverse phase material (Aqua; Phenomenex), followed by 3 cm of 5-μm Strong Cation Exchange material (Luna ...
-
bioRxiv - Systems Biology 2021Quote: ... and glycolysis cycle metabolites were identified by using 5 mM ammonium acetate in water pH 9.9 as buffer A and 100% acetonitrile as buffer B using a Luna 3 μM NH2 100 Å chromatography column (Phenomenex, Torrance, CA). The gradient used ...
-
bioRxiv - Biochemistry 2020Quote: ... We used SPE with Strata-X 200 mg/6 mL cartridges (Phenomenex Inc.) preconditioned with methanol and distilled water ...
-
bioRxiv - Molecular Biology 2023Quote: ... SDB-RPS cartridges (Strata™-X-C, 200 mg/6 ml, Phenomenex Inc.) were equilibrated with 8 bed volumes (BV ...
-
bioRxiv - Biochemistry 2020Quote: ... Crude separation was achieved by using a RP-18 Strata column (500 mg/6 mL, Phenomenex). The following buffers were used sequentially for crude separation ...
-
bioRxiv - Physiology 2023Quote: ... For peptide cleanup SDB-RPS cartridges (Strata™-X-C, 200 mg/6 mL, Phenomenex Inc.) were equilibrated with 8 bed volumes (BV ...
-
bioRxiv - Systems Biology 2021Quote: All the samples are analyzed with a nanoPOTS autosampler 6 equipped with a C18 SPE column (100 µm i.d., 4 cm, 300 Å C18 material, Phenomenex) and an LC column (50 µm i.d. ...
-
bioRxiv - Microbiology 2021Quote: ... The mixture was incubated for 6 h at a room temperature and separated using a Jupiter C18 HPLC column (Phenomenex) and acetonitrile gradient from 20 to 50% in 30 min in the presence of 0.1% trifluoroacetic acid ...
-
bioRxiv - Immunology 2022Quote: Trypsin-digested 6-Helix protein was then purified by high-pressure liquid chromatography (HPLC) on a C18 semi-preparative column (Phenomenex) over a 38-45% acetonitrile gradient in the presence of 0.1% trifluoroacetic acid ...
-
bioRxiv - Systems Biology 2023Quote: ... The trapping column (100 µm ID) was packed with 6 cm of 5 µm Kinetex C18 reversed phase (RP) resin (Phenomenex), while the nanospray emitter (75 µm ID ...
-
bioRxiv - Microbiology 2021Quote: ... Samples were analysed on a C18 column (Kinetex 5 μM, C18 100 Å, 250 × 4·6 mm, Phenomenex, Utrecht, The Netherlands) using a gradient of water/methanol with 0·1% formic acid (0–3 min ...
-
bioRxiv - Systems Biology 2020Quote: ... samples were four-fold diluted with 1% TFA in isopropanol and loaded onto SDB-RPS cartridges (Strata™-X-C, 30 mg/ 3 ml or Strata™-X-C, 200 mg/ 6 ml, Phenomenex Inc.). Before peptide loading ...
-
bioRxiv - Plant Biology 2019Quote: ... The lyophilized powder was resuspended in H2O containing 0.09% TFA (v/v) and applied to a 6-ml C18-T cartridge (Solid Phase Extraction Strata C18-T, Phenomenex, Torrance, CA, USA) previously equilibrated with solvent A (H2O ...
-
bioRxiv - Microbiology 2022Quote: ... mass spectrometer fitted with an Exion UHPLC system having a Kinetex 2.6 mm hydrophilic interaction liquid chromatography (HILIC) column (100 Å particle size, 150 mm length, and 3 mm internal diameter; Phenomenex, Intek Chromasol Pvt. Ltd., India). Nitrogen was used as the nebulizer gas ...