Labshake search
Citations for Gatan :
1 - 39 of 39 citations for KGF 2 FGF 10 Human 171a.a since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2021Quote: ... a movie containing 10 frames during exposure of 2 e-/Å2 was acquired on a K2 camera (Gatan). Dataset 1 was acquired on GFP-RFP-LC3 neurons at DIV 4 on MRC-LMB Krios 3 at nominal pixel size 3.44 Å/pix using a zero-centered tilt scheme from -30° to +60° then -30° to -30° (30/32 tomograms acquired were reconstructed) ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μL of protein was deposited on an UltrAuFoil 1.2/1.3 grid that was plasma cleaned at 25 mA for 2 minutes using a Solarus plasma cleaner (Gatan). Excess liquid was blotted away for 3 seconds in a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2022Quote: ... was applied to C-flat holey carbon grids (2/2, 400 mesh) which had been plasma cleaned for 30 seconds in a Solarus 950 plasma cleaner (Gatan) with a 4:1 ratio of O2/H2 ...
-
bioRxiv - Biochemistry 2019Quote: Negatively stained samples of PI3KC3-C1 and PI3KC3-C1:MBP-NRBF2MIT were prepared on continuous carbon grids that had been plasma cleaned in a 10% O2 atmosphere for 10 s using a Solarus plasma cleaner (Gatan Inc., Pleasanton, CA). 4 µl of PI3KC3-C1 at a concentration of 25 nM in 20 mM Tris ...
-
bioRxiv - Plant Biology 2023Quote: ... Images were collected digitally with a 2×2K Ultrascan1000 CCD (Gatan).
-
bioRxiv - Neuroscience 2022Quote: ... 10 nm or 50 nm pixel size) using an OnPoint (Gatan) back-scattered electron detector.
-
bioRxiv - Bioengineering 2022Quote: ... were glow-discharged for 10 s using the Solarus plasma cleaner (Gatan). 3 μl of the sample was applied to the grid and blotted with Vitrobot Mark IV (Thermofisher ...
-
bioRxiv - Immunology 2023Quote: ... were plasma-cleaned for 10 s in a Gatan Solarus 950 (Gatan). Samples were mixed with 10x concentrated 10 nm protein A gold (Aurion ...
-
bioRxiv - Molecular Biology 2020Quote: ... The grid was plasma-cleaned for 10 seconds using a Solarus plasma cleaner (Gatan). An aliquot (3.5 µL ...
-
bioRxiv - Cell Biology 2020Quote: ... 200 mesh Quantifoil™ Au R2/2 grids were plasma-cleaned in a Gatan Solarus 950 (Gatan) for 10 sec ...
-
bioRxiv - Neuroscience 2020Quote: ... were plasma cleaned with H2 and O2 for 10 s using a plasma cleaning system (Gatan), sterilized with UV light for 30 min ...
-
bioRxiv - Cell Biology 2022Quote: ... Movies consisting of 8-10 frames were recorded using a K2 Summit direct electron detector (Gatan), with a target total electron dose of 80 e−/Å2 ...
-
bioRxiv - Molecular Biology 2020Quote: ... at 4008×2672 pixels resolution using a 2 seconds exposure operated through Gatan Microscopy Suite (Gatan, CA, USA). A total of 20 images were captured at 100,000x magnification from four different grids ...
-
bioRxiv - Biochemistry 2022Quote: The datasets were collected on gold grids (UltrAuFoil R2/2 200 mesh) plasma cleaned just before use (Gatan Solarus plasma cleaner ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μL of protein was deposited on a CF-1.2/1.3 grid that was plasma cleaned at 25 mA for 30 seconds using a Solarus plasma cleaner (Gatan). Excess liquid was blotted away for 6 seconds in a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2023Quote: ... 1.2/1.3R 400 mesh Cu grids were plasma-cleaned for 30 sec in a Solarus 950 plasma cleaner (Gatan). All cryo-EM samples (2.5ul ...
-
bioRxiv - Biochemistry 2023Quote: ... Grids were glow discharged for 25 s at 50 W (UltrAuFoil R1.2/1.3) or 10 s at 5 W (Lacey) with a Solarus II plasma cleaner (Gatan). Vitrification was carried out using a Vitrobot Mark IV (ThermoScientific) ...
-
bioRxiv - Immunology 2020Quote: ... Quantifoil R 2/1 holey carbon copper grid (Cu 400 mesh) were treated with Ar/O2 plasma (Solarus plasma cleaner, Gatan) for 10s before sample loading ...
-
bioRxiv - Synthetic Biology 2020Quote: ... Quantifoil R 2/1 holey carbon copper grids (Cu 400 mesh) were pre-treated with Ar/O2 plasma (Solarus plasma cleaner, Gatan) for 10 s prior to sample application ...
-
bioRxiv - Biophysics 2024Quote: ... negatively stained with 2% (w/v) uranyl formate and analyzed by negative-stain electron microscopy with a Rio16 CMOS camera (Gatan) on a Tecnai Spirit (FEI Company ...
-
bioRxiv - Molecular Biology 2022Quote: Quantifoil R3.5/1 Au200 grids were plasma cleaned for 10s with a 80:20 oxygen:hydrogen mix (Solarus II Model 955, Gatan). 4uL cells were added to grid ...
-
bioRxiv - Cell Biology 2022Quote: ... TEM images were collected with a JEOL JEM 1011 electron microscope and recorded with a 2 Mp charge coupled device camera (Gatan Orius).
-
bioRxiv - Biophysics 2019Quote: ... 3 μL of purified TniQ-Cascade ranging from 100 nM to 2 μM was incubated with plasma treated (H2/O2 gas mix, Gatan Solarus) CF400 carbon-coated grids (EMS ...
-
bioRxiv - Biochemistry 2022Quote: ... Movies comprising 20 frames with a 20 seconds exposure time and a total dose of 66 e Å-2 were collected on a K2 Summit direct detector (Gatan) in counting mode at a nominal magnification of 64000 which gave a pixel size of 2.2 Å ...
-
bioRxiv - Bioengineering 2023Quote: ... TEM images were collected with a JEOL JEM 1011 electron microscope and recorded with a 2 Mp charge coupled device camera (Gatan Orius).
-
bioRxiv - Biochemistry 2023Quote: ... Quantifoil R1.2/1.3 300 mesh Cu holey carbon grids were glow-discharged for 30 s with a mixture of H2 and O2 (1:2) using a glow-discharge cleaning system (Solarus II Plasma Cleaner, Gatan, Inc). The KTF1-SPT4-bound Pol V TEC was mixed with 0.005% Tween-20 (Sigma ...
-
bioRxiv - Bioengineering 2022Quote: ... and sample Ad-DogTag:DogCatcher-RBD were applied to a 1/2 Cu-mesh C-flat grid that had been plasma-cleaned for 10 s using a 25% v/v O2 / 75% v/v Ar mixture in a Solarus 950 Plasma Cleaner (Gatan). Grids were manually plunge frozen in liquid ethane ...
-
bioRxiv - Neuroscience 2019Quote: ... Images with 8192×8192 or 4096×4096 pixels were collected at 7-10 nm/pixel along both the x- and y-axes using the Digital Micrograph software (Gatan). Image series of regions of interest were further processed ...
-
bioRxiv - Microbiology 2022Quote: ... Quantifoil Cu 1.2/1.3 300 grids were glow-discharged for 10 sec in a pre-set program using a Solarus II plasma cleaner (Gatan). Sample was applied to a grid as a 3.5 μL drop in the environmental chamber of a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... Prior to sample loading the grids were subjected to Ar/O2 plasma cleaning for 10 s on a Solarus 950 plasma cleaner (Gatan). After the blotting step ...
-
bioRxiv - Microbiology 2022Quote: ... Movies were acquired in super resolution and CDS mode with a slit width of 10 eV using a K3 detector (Gatan) for 3.3 seconds during which 40 movie frames were collected with a 1 e-/Å2 per frame ...
-
bioRxiv - Bioengineering 2023Quote: ... Prior to sample application the grids were glow-discharged using Ar/O2 plasma for 10 s on a Solarus 950 plasma cleaner (Gatan). 0.5 μL of 0.04 mM lauryl maltose neopentyl glycol (LMNG ...
-
bioRxiv - Microbiology 2023Quote: Holey silicon dioxide film coated grids (200 mesh QuantifoilTM SiO2 R1.2/20) were placed into PDMS-coated dishes and were plasma-cleaned for 10 s in a Gatan Solarus 950 (Gatan). The dish was sterilized with 70% ethanol and washed twice with DMEM ...
-
bioRxiv - Microbiology 2023Quote: ... coated 35 mm dishes and the carbon-coated sapphire discs were plasma-cleaned for 10 seconds (s) in a Solarus 950 (Gatan). The discs were placed inside the dishes with the “F” facing up ...
-
bioRxiv - Biophysics 2022Quote: 3.0 µl of purified ELIC nanodiscs at an approximately concentration of 1.2 mg/ml were pipetted onto Quantifoil R2/2 copper grids post plasma cleaning in an H2/O2 plasma for 60 s (Solaris 950. Gatan, Warrendale, PA). Agonist bound samples were prepared by combining the purified channels with cysteamine to a final agonist concentration of 10 mM ...
-
bioRxiv - Neuroscience 2023Quote: ... was applied to C-flat-1.2/1.3-2C-T copper grids that had been glow discharged for 10 s in Argon/Oxygen atmosphere using a Solarus plasma cleaner (Gatan, Inc.). The grids were blotted for 2 s with a blot force of −1 at 4 °C under 100% humidity and were flash-frozen in liquid ethane using a FEI Vitrobot Mark IV (FEI) ...
-
bioRxiv - Plant Biology 2022Quote: ... Images were acquired with a scanning electron microscope TFS Quanta 250 3VIEW (FEI, Hillsboro, OR) at 1.8-2 keV with an integrated 3VIEW stage and a backscattered electron detector (Gatan Inc., Pleasanton, CA, USA). Images were aligned and smoothed using the plugins MultiStackReg and 3D median filter on ImageJ.
-
bioRxiv - Molecular Biology 2024Quote: ... Images were recorded at a nominal magnification of 12,000× magnification under ∼15 electrons/Å2 conditions at 5 to 10 μm under-focus by using a Gatan K2 Summit direct electron detector (Gatan Inc., Pleasanton, CA). At least 250 individual immature particles of each mutant were measured using ImageJ software ...
-
bioRxiv - Biophysics 2022Quote: ... 3 μl of ELIC nanodiscs at ~1.2 mg/ml were pipetted onto Quantifoil R2/2 copper grids (which had previously been cleaned using a Gatan Solaris 950 in a H2/O2 plasma for 60 s), after which each grid was blotted for 2 s in a 100% humidity environment and vitrified in liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...