Labshake search
Citations for Gatan :
1 - 45 of 45 citations for 6 Chloro 9 fluorobenz 9 isoquinoline 5 10 dione since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2022Quote: ... Images were acquired using a post-column high-resolution (9 106 pixels) camera (Rio9; Gatan) and processed with Digital Micrograph (Gatan ...
-
bioRxiv - Biophysics 2022Quote: ... Grids were imaged on an FEI Tecnai Spirit Transmission Electron Microscope at 120 kV with a Rio 9 3K x 3K CCD camera (Gatan).
-
bioRxiv - Cell Biology 2023Quote: ... Electron micrographs were taken on JEOL JEM1400 (120 kV) equipped with an Orius 832 digital camera with 9 µm pixels (Gatan). To test the percentage of the ciliary vesicle positive centriole ...
-
bioRxiv - Cell Biology 2023Quote: ... Electron micrographs were taken on JEOL JEM1400 (120kV) equipped with an Orius 832 digital camera with 9 µm pixel (Gatan). To test the percentage of the ciliary vesicle positive centriole ...
-
bioRxiv - Microbiology 2024Quote: ... Images were obtained using a JEM-1400 (Jeol, Tokyo, Japan) transmission electron microscope equipped with a Rio-9 camera (Gatan Inc., Pleasanton, CA, USA) at 120 kV.
-
bioRxiv - Biophysics 2021Quote: ... the samples were sputtered with a layer of 5-6-nm platinum (coater: Model 681; Gatan, USA).
-
bioRxiv - Immunology 2020Quote: ... Quantifoil R 0.6/1 holey carbon grids were freshly glow discharged for 5 s prior with a Solarus 950 Plasma Cleaner (Gatan, Pleasanton, CA) prior to application of 3 uL protein sample ...
-
bioRxiv - Biochemistry 2023Quote: ... Grids were glow discharged for 25 s at 50 W (UltrAuFoil R1.2/1.3) or 10 s at 5 W (Lacey) with a Solarus II plasma cleaner (Gatan). Vitrification was carried out using a Vitrobot Mark IV (ThermoScientific) ...
-
bioRxiv - Molecular Biology 2024Quote: ... Images were recorded at a nominal magnification of 12,000× magnification under ∼15 electrons/Å2 conditions at 5 to 10 μm under-focus by using a Gatan K2 Summit direct electron detector (Gatan Inc., Pleasanton, CA). At least 250 individual immature particles of each mutant were measured using ImageJ software ...
-
bioRxiv - Biophysics 2021Quote: ... the samples were sputtered with 6-7 nm platinum (Coater: Model 681; Gatan, USA).
-
bioRxiv - Plant Biology 2022Quote: ... Movies were automatically recorded by SerialEM using image shift (5×5 holes per stage position) and a K3 Direct Detection Camera (Gatan, AMETEK, Pleasanton, CA, USA) in CDS mode at a nominal magnification of 60,000× at the camera level ...
-
bioRxiv - Cell Biology 2021Quote: ... Single-axis cryo-electron tomography was performed at 3-6 μm defocus with a K2 Summit direct electron detector (Gatan) operating in counting mode (at 5 e-per pixel per second ...
-
bioRxiv - Biophysics 2021Quote: ... that had been freshly plasma cleaned for 6 seconds at 15 Watts (75% nitrogen/25% oxygen atmosphere) using a Solarus plasma cleaner (Gatan, Inc.). Grids were manually blotted using Whatman No ...
-
bioRxiv - Neuroscience 2022Quote: ... we recorded “movies’’ with 5-6 frames per movie using a Gatan K2TM or K3TM direct electron detection camera with a BioQuantumTM Imaging Filter (Gatan, Inc). The tilt series were collected at higher magnification (39000X ...
-
bioRxiv - Molecular Biology 2019Quote: ... that had been previously plasma cleaned in a 75% argon / 25% oxygen atmosphere at 15 Watts for 6 seconds using a Solarus plasma cleaner (Gatan, Inc). The grids were loaded into a Vitrobot (ThermoFisher ...
-
bioRxiv - Biochemistry 2021Quote: ... Images of the H3-H4 octasome were recorded with 6 second exposure times on an energy-filtered K3 direct electron detector (Gatan, USA) in the electron counting mode with a slit width of 25 eV ...
-
bioRxiv - Molecular Biology 2023Quote: ... that had undergone plasma cleaning for 6 seconds in a mixture of O2 and H2 by a Gatan Solarus 950 (Gatan, Inc). Grids were blotted for 3.5-5 seconds at a force of -5 ...
-
bioRxiv - Biochemistry 2019Quote: Negatively stained samples of PI3KC3-C1 and PI3KC3-C1:MBP-NRBF2MIT were prepared on continuous carbon grids that had been plasma cleaned in a 10% O2 atmosphere for 10 s using a Solarus plasma cleaner (Gatan Inc., Pleasanton, CA). 4 µl of PI3KC3-C1 at a concentration of 25 nM in 20 mM Tris ...
-
bioRxiv - Biochemistry 2020Quote: ... blotted for 5 s and plunge-frozen into liquid ethane using Cryoplunge 3 (Gatan).
-
bioRxiv - Neuroscience 2022Quote: ... 10 nm or 50 nm pixel size) using an OnPoint (Gatan) back-scattered electron detector.
-
bioRxiv - Biophysics 2019Quote: ... Dose-fractionated data (3-5 frames per projection image) were collected using Digital Micrograph (Gatan). Magnifications varied depending on microscope ...
-
bioRxiv - Bioengineering 2022Quote: ... were glow-discharged for 10 s using the Solarus plasma cleaner (Gatan). 3 μl of the sample was applied to the grid and blotted with Vitrobot Mark IV (Thermofisher ...
-
bioRxiv - Immunology 2023Quote: ... were plasma-cleaned for 10 s in a Gatan Solarus 950 (Gatan). Samples were mixed with 10x concentrated 10 nm protein A gold (Aurion ...
-
bioRxiv - Microbiology 2020Quote: ... Quantifoil R2/1 grids were plasma cleaned for 5 seconds using a Solarus plasma cleaner (Gatan). In the humidity-controlled chamber of the Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2023Quote: ... 1063 movies (40 frames /movie; 5 s exposure) were collected using a Quantum K2 LS detector (Gatan) at a magnification of 165.000x ...
-
bioRxiv - Molecular Biology 2020Quote: ... The grid was plasma-cleaned for 10 seconds using a Solarus plasma cleaner (Gatan). An aliquot (3.5 µL ...
-
bioRxiv - Immunology 2020Quote: ... which had been plasma-cleaned for 5 seconds using a mixture of Ar/O2 (Gatan Solarus 950 Plasma system). For the BG505 SOSIP-T33_dn2 nanoparticle sample ...
-
bioRxiv - Immunology 2020Quote: ... which had been plasma-cleaned for 5 seconds using a mixture of N2/O2 (Gatan Solarus 950 Plasma system). The grid was blotted and plunged into liquid Ethane using a Vitrobot Mark IV (ThermoFisher).
-
bioRxiv - Immunology 2020Quote: ... which had been plasma-cleaned for 5 seconds using a mixture of N2/O2 (Gatan Solarus 950 Plasma system). The grid was blotted and plunged into liquid Ethane using a Vitrobot Mark IV (ThermoFisher) ...
-
bioRxiv - Immunology 2020Quote: ... which had been plasma-cleaned for 5 seconds using a mixture of N2/O2 (Gatan Solarus 950 Plasma system). The grid was blotted and plunged into liquid ethane using a Vitrobot Mark IV (ThermoFisher).
-
bioRxiv - Neuroscience 2020Quote: ... were plasma cleaned with H2 and O2 for 10 s using a plasma cleaning system (Gatan), sterilized with UV light for 30 min ...
-
bioRxiv - Cell Biology 2022Quote: ... Movies consisting of 8-10 frames were recorded using a K2 Summit direct electron detector (Gatan), with a target total electron dose of 80 e−/Å2 ...
-
bioRxiv - Cell Biology 2021Quote: ... a movie containing 10 frames during exposure of 2 e-/Å2 was acquired on a K2 camera (Gatan). Dataset 1 was acquired on GFP-RFP-LC3 neurons at DIV 4 on MRC-LMB Krios 3 at nominal pixel size 3.44 Å/pix using a zero-centered tilt scheme from -30° to +60° then -30° to -30° (30/32 tomograms acquired were reconstructed) ...
-
bioRxiv - Bioengineering 2020Quote: ... Both the exposed top face and cross-section intended for PFIB-SEM slicing were coated with 5 nm of gold using a Precision Etching Coating System (PECS II) coater (Gatan Inc., CA, USA) to minimize charging effects.
-
bioRxiv - Biophysics 2024Quote: ... equipped with a BioQuantum Imaging filter (slit width 20 eV) and either a K3 (tr-Spotiton datasets) or a K2 (5°C dataset) direct electron detector (Gatan, Inc., Pleasanton, CA). All tr-Spotiton grid images were recorded in counting mode with a physical pixel size of 0.844 Å ...
-
bioRxiv - Molecular Biology 2022Quote: Quantifoil R3.5/1 Au200 grids were plasma cleaned for 10s with a 80:20 oxygen:hydrogen mix (Solarus II Model 955, Gatan). 4uL cells were added to grid ...
-
bioRxiv - Bioengineering 2022Quote: ... and sample Ad-DogTag:DogCatcher-RBD were applied to a 1/2 Cu-mesh C-flat grid that had been plasma-cleaned for 10 s using a 25% v/v O2 / 75% v/v Ar mixture in a Solarus 950 Plasma Cleaner (Gatan). Grids were manually plunge frozen in liquid ethane ...
-
bioRxiv - Neuroscience 2019Quote: ... Images with 8192×8192 or 4096×4096 pixels were collected at 7-10 nm/pixel along both the x- and y-axes using the Digital Micrograph software (Gatan). Image series of regions of interest were further processed ...
-
bioRxiv - Microbiology 2022Quote: ... Quantifoil Cu 1.2/1.3 300 grids were glow-discharged for 10 sec in a pre-set program using a Solarus II plasma cleaner (Gatan). Sample was applied to a grid as a 3.5 μL drop in the environmental chamber of a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... Prior to sample loading the grids were subjected to Ar/O2 plasma cleaning for 10 s on a Solarus 950 plasma cleaner (Gatan). After the blotting step ...
-
bioRxiv - Microbiology 2022Quote: ... Movies were acquired in super resolution and CDS mode with a slit width of 10 eV using a K3 detector (Gatan) for 3.3 seconds during which 40 movie frames were collected with a 1 e-/Å2 per frame ...
-
bioRxiv - Bioengineering 2023Quote: ... Prior to sample application the grids were glow-discharged using Ar/O2 plasma for 10 s on a Solarus 950 plasma cleaner (Gatan). 0.5 μL of 0.04 mM lauryl maltose neopentyl glycol (LMNG ...
-
bioRxiv - Microbiology 2023Quote: Holey silicon dioxide film coated grids (200 mesh QuantifoilTM SiO2 R1.2/20) were placed into PDMS-coated dishes and were plasma-cleaned for 10 s in a Gatan Solarus 950 (Gatan). The dish was sterilized with 70% ethanol and washed twice with DMEM ...
-
bioRxiv - Microbiology 2023Quote: ... coated 35 mm dishes and the carbon-coated sapphire discs were plasma-cleaned for 10 seconds (s) in a Solarus 950 (Gatan). The discs were placed inside the dishes with the “F” facing up ...
-
bioRxiv - Neuroscience 2023Quote: ... was applied to C-flat-1.2/1.3-2C-T copper grids that had been glow discharged for 10 s in Argon/Oxygen atmosphere using a Solarus plasma cleaner (Gatan, Inc.). The grids were blotted for 2 s with a blot force of −1 at 4 °C under 100% humidity and were flash-frozen in liquid ethane using a FEI Vitrobot Mark IV (FEI) ...