Labshake search
Citations for GVS Life Sciences :
1 - 42 of 42 citations for Mouse Vacuole Membrane Protein 1 VMP1 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2023Quote: ... Proteins were transferred to 0.45 μm nitrocellulose membranes (GVS) using a Trans-Blot semi-dry transfer unit (Bio-Rad) ...
-
bioRxiv - Immunology 2023Quote: ... Proteins were then transferred to nitrocellulose membranes (GVS NitroBind™. EP2HY00010) for 1hr at 90 V ...
-
bioRxiv - Cancer Biology 2022Quote: ... proteins were transferred from the gel to a nitrocellulose membrane (GVS Life Science) using an electroblotting unit (VWR #BTV100) ...
-
bioRxiv - Cell Biology 2020Quote: ... Resolved proteins were then transferred to a supported nitrocellulose transfer membrane (GVS Filter Technology) in 10% methanol transfer buffer (Geneflow) ...
-
bioRxiv - Molecular Biology 2022Quote: Lysates of cells or mouse tissues (20-100 μg) were subjected to SDS-PAGE and transferred onto a nitrocellulose membrane (GVS Life Science) with a wet blot transfer system (VWR) ...
-
bioRxiv - Biochemistry 2023Quote: ... transferred to nitrocellulose membrane (GVS, 1215471), blocked with 3% dry milk dissolved in TBS-T (150 mM NaCl ...
-
bioRxiv - Microbiology 2020Quote: ... the arrays were probed at 1/100 dilution in protein array blocking buffer (GVS) supplemented with E ...
-
bioRxiv - Cell Biology 2020Quote: ... in methanol:chloroform (9:1 v/v) solvent was loaded on to 0.45 µm supported nitrocellulose membrane (GVS, Sanford, ME). The membrane was air-dried for 1 hour at room temperature ...
-
bioRxiv - Microbiology 2021Quote: ... and transferred to a nitrocellulose membrane (GVS) using a Trans-Blot Turbo transfer system (Bio-Rad) ...
-
bioRxiv - Immunology 2020Quote: ... the specimens were diluted 1:100 in 1X Protein Array Blocking Buffer (GVS Life Sciences, Sanford, ME), transferred to the slides and incubated overnight at 4°C ...
-
bioRxiv - Immunology 2024Quote: ... Serum and BALF samples were diluted 1:100 in protein array blocking buffer (GVS, Sanford, ME, USA) supplemented with E ...
-
bioRxiv - Plant Biology 2021Quote: ... followed by transfer onto nitrocellulose membranes (GVS North America) for western blot analysis.
-
bioRxiv - Microbiology 2023Quote: Nitrocellulose membrane (GVS, white disk diam. 47 mm, hydrophilic) was placed upon complete medium agar in 60×15 mm of petri-dish ...
-
Optimization and deoptimization of codons in SARS-CoV-2 and the implications for vaccine developmentbioRxiv - Evolutionary Biology 2022Quote: ... After being transferred to nitrocellulose filter membranes (GVS, Sanford, USA), the samples were detected using polyclonal rabbit anti-SARS-CoV-2 S antibodies at a dilution of 1:2,000.
-
bioRxiv - Microbiology 2023Quote: ... Assays using nylon membrane (GVS, white disk diam. 47mm, hydrophilic) and PVDF membrane (Durapore ...
-
bioRxiv - Microbiology 2023Quote: ... 10µl aliquots of coculture were applied to nitrocellulose membranes (0.2µm, GVS) atop LB-agar (basal CRISPRi ...
-
bioRxiv - Cell Biology 2023Quote: ... and transferred to PVDF membranes (Bio-Rad and GVS Filter Technology). Membranes were blocked for 30 minutes in 5% Bovine Serum Albumin and incubated with primary antibodies against MRC2 (1:1,200 ...
-
bioRxiv - Molecular Biology 2024Quote: ... 2 μm (Track-Etched Membrane PCTE filter; GVS Japan, Tokyo, Japan), and 0.7 μm (GF/F glass-fiber filter ...
-
bioRxiv - Biochemistry 2019Quote: ... followed by transfer to a 0.45 micron nitrocellulose membrane (GVS North America). Membranes were analyzed using an antiFLAG antibody (Sigma ...
-
bioRxiv - Plant Biology 2022Quote: ... and subsequently transferred to a 0.45 μm nitrocellulose membrane (GVS, Sanford, ME). For detection of Cas9 protein ...
-
bioRxiv - Microbiology 2023Quote: ... 10µl aliquots of each culture were applied to nitrocellulose membranes (0.2µm, GVS) atop LB-agar+100µM IPTG or LBNS-agar+100µM IPTG and dried down by flame-sterilization ...
-
bioRxiv - Microbiology 2023Quote: ... Protein was transferred to nitrocellulose (0.2µm; GVS) via semi-dry transfer with a TransBlot Turbo transfer system (BioRad ...
-
bioRxiv - Bioengineering 2023Quote: ... a 0.22 μm pore size membrane (47 mm-Manga Nylon Filter, GVS-Lifescience) was inserted in the middle of the chamber to separate the cells from the circulating fluid medium ...
-
bioRxiv - Microbiology 2023Quote: ... 10µl aliquots of each liquid co-culture applied to nitrocellulose membranes (0.2µm, GVS) atop LB-agar+100µM IPTG and dried down by flame-sterilization to encourage interbacterial competition ...
-
bioRxiv - Microbiology 2021Quote: ... Nine-day old mycelia grown on a Polycarbonate Track Etched (PCTE) Membrane (GVS, Italy) placed on top of 1% Avicel plates were harvested ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... The solution was mixed with the haploid mating partner on nylon membranes (GVS, Sanford NE) at an excess of 1:100 (100 barcoded cells for each MATα spore ...
-
bioRxiv - Microbiology 2020Quote: ... cells were then vacuum-filtered onto 0.2µm polycarbonate track etched membrane filters (GVS Life Sciences) and mounted in Vectashield mounting medium for imaging (Vector laboratories) ...
-
bioRxiv - Microbiology 2024Quote: ... Samples for biogenic silicate (Bsi) were filtered on polycarbonate membrane filters (0.8 μm, GVS, Italy) and measured according to Koistinen et al ...
-
bioRxiv - Microbiology 2021Quote: ... commune strains were pre-cultured on a Poretics™ Polycarbonate Track Etched (PCTE) Membrane (GVS, Italy) placed on top of glucose medium for 5 days at 30°C ...
-
bioRxiv - Microbiology 2023Quote: ... The co-culture apparatus was prepared with a sterile 0.65 µm nylon membrane (GVS North America). Each side contained 20 mL of VDM ...
-
bioRxiv - Biochemistry 2020Quote: ... hybridization and color development were done according to [29] using nitrocellulose transfer membrane (GVS Group, Bologna, Italy) and Towbin buffer with methanol ...
-
bioRxiv - Microbiology 2023Quote: ... were mixed with protein array buffer (Maine manufacturing, GVS Group, Italy) including 4 μl/ml EZ block™ protease inhibitor cocktail (Bio Vision ...
-
bioRxiv - Microbiology 2024Quote: ... commune monokaryotic strains were first pre-cultured on a Poretics™ Polycarbonate Track Etched (PCTE) Membrane (GVS, Italy) placed on top of SCMM plates for 5 days at 30°C ...
-
bioRxiv - Microbiology 2024Quote: ... mycelium was grown from plug inoculum on top of a Poretics™ Polycarbonate Track Etched (PCTE) Membrane (GVS, Italy) on solid SCMM for 5 – 7 days at 30 °C ...
-
bioRxiv - Neuroscience 2020Quote: ... Monoclonal antibodies were diluted in protein array blocking buffer (GVS, Sanford, ME, USA) to a final concentration of 5 ng/ml ...
-
bioRxiv - Microbiology 2024Quote: ... Proteins were transferred via electroblotting to nitrocellulose (Main Manufacturing LLC) or PVDF (GVS Filter Tech 1212783 ...
-
bioRxiv - Genetics 2019Quote: ... we inoculated HPM plates with either a polycarbonate Track Etched 76 mm 0.1 μm membrane disk (Poretics, GVS Life Sciences, USA)(Psk1xS5 and Psk7xS5 ...
-
bioRxiv - Microbiology 2021Quote: Mycelia were grown in triplicate for 72h at 30°C on a Poretics™ Polycarbonate Track Etched (PCTE) Membrane (GVS, Italy) placed on top of solid minimal medium ...
-
bioRxiv - Microbiology 2021Quote: ... monokaryons of strains H4-8 or H4-8 Δroc1 :: roc1-HA were grown on medium with Avicel on Poretics™ Polycarbonate Track Etched (PCTE) Membrane (GVS, Italy). After 9 days 10 colonies were collected per replicate and washed twice in Tris-buffered saline (TBS ...
-
bioRxiv - Cell Biology 2023Quote: Immunoblot analyses: Lysates of cells (20–100 μg) were subjected to SDS-PAGE and transferred onto a nitrocellulose membrane (GVS Life Science) with a wet blot transfer system (VWR #BTV100) ...
-
bioRxiv - Bioengineering 2021Quote: ... The cardiac compartment and microchannels are fluidically connected through a 10 μm thick polyester (PE) porous membrane with 8 μm diameter pore-size (GVS Life Sciences, USA). The cardiac compartments consist of dumbbell-shaped wells similar to what has been reported previously [25] in which cardiac microtissues were fabricated ...
-
bioRxiv - Bioengineering 2021Quote: ... The cardiac and vascular compartments are fluidically connected through a 10 μm thick polyester (PE) porous membrane with 8 μm diameter pore-size (GVS Life Sciences, USA). The cardiac compartments consist of dumbbell-shaped wells similar to what has been reported previously 25 in which 3D cardiac tissues were fabricated ...