Labshake search
Citations for Molecular Devices :
301 - 350 of 850 citations for 2 Amino 6 chloro 9 3 5 di O p toluoyl beta D 2 deoxyribofurnanosyl purine since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... Data were low-pass filtered at 2 kHz and acquired at 20 kHz with an Axon Multiclamp 700B amplifier (Molecular Devices, Sunnyvale, U.S.A.) using MATLAB (Mathworks ...
-
bioRxiv - Cell Biology 2023Quote: ... 2 μM Rab were incubated with varying amounts of GEF in a SpectraMax M3 Multi-Mode Microplate Reader (Molecular Devices, San Jose, USA) and after base line stabilization ...
-
bioRxiv - Neuroscience 2023Quote: ... The recordings were low-pass filtered at 2 kHz and digitized at 10 kHz using a Multiclamp 700B amplifier (Molecular Devices, Sunnyvale, CA), Digidata 1322A digitizer (Molecular Devices) ...
-
bioRxiv - Neuroscience 2024Quote: ... Signals were low pass filtered at 2 kHz and sampled at 50 kHz under the control of pClamp 11 (RRID: SCR_011323, Molecular Devices, San Jose, USA). Borosilicate glass pipettes with resistance at 4-6 MΩ (O.D ...
-
bioRxiv - Neuroscience 2020Quote: Recordings were made using an Axopatch 1-D (Molecular Devices), filtered at 5 kHz and collected at 20 kHz using custom procedures written for NIDAQ and IGOR Pro (National Instruments and WaveMetrics ...
-
bioRxiv - Neuroscience 2021Quote: ... using a Digidata 1322A A/D interface (Molecular Devices, CA), at a sampling rate of 20 kHz (low pass filtered at 10 kHz ...
-
bioRxiv - Neuroscience 2022Quote: ... sampled through a Digidata 1440a A/D converter (Molecular Devices) to a PC computer ...
-
bioRxiv - Developmental Biology 2022Quote: ... D/A converter combined with Clampex (Axon Instruments, Molecular Devices). Signals were filtered at 10 kHz ...
-
bioRxiv - Neuroscience 2021Quote: ... using a Digidata 1322A A/D interface (Molecular Devices, CA), at a sampling rate of 20 kHz (low pass filtered at 10 kHz ...
-
bioRxiv - Neuroscience 2022Quote: ... using a Digidata 1322A A/D interface (Molecular Devices, CA), at a sampling rate of 20 kHz (low pass filtered at 10 kHz ...
-
bioRxiv - Neuroscience 2024Quote: ... and the Digidata 1440A A/D converter (Molecular Devices, USA) connected to a computer ...
-
bioRxiv - Biophysics 2024Quote: ... Digidata 1440A A/D converter and Clampex software (Molecular Devices). Pipette capacitance was compensated in all recordings ...
-
bioRxiv - Neuroscience 2023Quote: ... fed to an A/D interface (Digidata 1320A, Molecular Devices), and acquired at 50kHZ using Clampex (v10 ...
-
bioRxiv - Neuroscience 2023Quote: ... Membrane currents and I-V curve were recorded and plotted in the whole-cell configuration by pulse software with the EPC-9 amplifier (HEKA, Germany) and processed with the Igor Pro (WaveMetrics, USA) and Clampfit 10 software (Axon Instruments, Molecular Devices, USA). Membrane currents was recorded at −60 mV ...
-
bioRxiv - Neuroscience 2023Quote: ... Membrane currents and I-V curve were recorded and plotted in the whole-cell configuration by pulse software with the EPC-9 amplifier (HEKA, Germany) and processed with the Igor Pro (WaveMetrics, USA) and Clampfit 10 software (Axon Instruments, Molecular Devices, USA). I-V curve was recorded at a holding potential from –80 mV to 80 mV with 20 mV step voltages ...
-
bioRxiv - Neuroscience 2020Quote: ... FlexStation 3 (Molecular Devices; San Jose, CA) was set to 37°C and used for kinetic recording of 520 nm and 570 nm emission for 30 minutes ...
-
bioRxiv - Cell Biology 2023Quote: ... using a Flex Station 3 (Molecular Devices) microplate fluorescence spectrophotometer (λex = 341 nm ...
-
bioRxiv - Neuroscience 2021Quote: ... DRGs to record spontaneous afferent population activity for a minimum of 25 seconds (50 kHz, Digidata 1322A 16 Bit DAQ, Molecular Devices, U.S.A., Figure 2). Signals were amplified (5000x ...
-
bioRxiv - Neuroscience 2020Quote: ... with ACSF-filled glass microelectrodes (2-4 MΩ) positioned within layer II/III of the V1 using an Axopatch 200B amplifier (Molecular devices, San Jose, CA). Electric stimulation (100 μsec duration ...
-
bioRxiv - Neuroscience 2021Quote: ... synaptic currents were filtered at 2 kHz and digitized at 10 kHz (amplifier in-built 8-pole low-pass Bessel filter and Molecular Devices Digidata 1322A, respectively). Recordings used for analysis were post-hoc filtered at 1 kHz.
-
bioRxiv - Neuroscience 2021Quote: ... Data were low-pass filtered at 2 kHz and digitized at 10 kHz with a Digidata 1440 interface controlled by pClamp Software (Molecular Devices, Union City, CA).
-
bioRxiv - Physiology 2021Quote: ... Images were acquired at a frequency of 2 Hz with an exposure time of 500 ms using the MetaMorph software program (ver. 7.8; Molecular Devices, San Jose, CA, USA) in stream acquisition mode ...
-
bioRxiv - Immunology 2022Quote: ... The cells were incubated with LPS with and without a NOX2 inhibitor for 2 h in the assay media and fluorescence was measured using a SpectraMax plate reader (Molecular Devices, San Jose, CA). Fluorescence values were normalized to cell number measured using the Presto Blue Cell Viability Assay (ThermoFischer Scientific ...
-
Community-based Reconstruction and Simulation of a Full-scale Model of Region CA1 of Rat HippocampusbioRxiv - Neuroscience 2024Quote: ... Single intracellular recordings were made using sharp microelectrodes (tip resistance, 90-190 MΩ) filled with 2% biocytin in 2M KMeSO4 under current-clamp (Axoprobe; Molecular Devices, Palo Alto, CA). Electrophysiological characteristics of the recorded neurons were obtained from voltage responses to 400 ms current pulses between -1 and +0.8 nA and recorded with pClamp software (Axon Instruments ...
-
Macropinocytosis mediates resistance to loss of glutamine transport in triple-negative breast cancerbioRxiv - Cancer Biology 2024Quote: ... CCK8 reagent was added for 2 h and absorbance measured at 450 nm on a Spectramax® 190 Microplate Reader (Molecular Devices, CA, USA) at timepoints indicated ...
-
Dynamic Effects of Ventral Hippocampal NRG3/ERBB4 Signaling on Nicotine Withdrawal-Induced ResponsesbioRxiv - Neuroscience 2023Quote: Currents were low pass filtered at 2 kHz and digitized at 20 kHz using a Digidata 1550B acquisition system (Molecular Devices, San Jose, CA) coupled to the Multiclamp 700B amplifier (Molecular Devices ...
-
bioRxiv - Neuroscience 2024Quote: ... Signals were recorded at different membrane potentials under voltage clamp conditions for about 2 min (0mV for inhibitory events and −70mV for excitatory events) using a MultiClamp 700 B amplifier (Molecular Devices, Foster City, CA) and Clampfit software ...
-
bioRxiv - Cell Biology 2020Quote: ... The cells were then loaded with Calcium 6-QF (Molecular Devices) in a Minimum Essential Medium:Hanks’ balanced salt solution (MEM:HBSS ...
-
bioRxiv - Immunology 2022Quote: ... in conjunction with the FLIPR Calcium 6 dye kit (Molecular Devices) as previously described (Dal Porto et al. ...
-
bioRxiv - Microbiology 2022Quote: ... Images were acquired using Metamorph 6 imaging software (Molecular Devices, Inc). Images were analysed with ImageJ (http://rsb.info.nih.gov/ij/ ...
-
bioRxiv - Immunology 2023Quote: ... in conjunction with the FLIPR Calcium 6 dye kit (Molecular Devices). On the day of the experiments ...
-
bioRxiv - Neuroscience 2020Quote: ... The currents were filtered at 1 kHz and digitized at 10 kHz using a Digidata 1322A analog-to-digital converter and the Clampex 9 software package (Axon CNS Molecular Devices, Sunnyvale, CA). Data were analyzed by the customized macro for IGOR PRO software (Mosharov ...
-
bioRxiv - Molecular Biology 2024Quote: ... and images were taken for 9 fields of view in each well under 40x magnification by the ImageXpress Micro XLS System (Molecular Devices, LLC, USA) using DAPI and Texas Red filters ...
-
bioRxiv - Neuroscience 2022Quote: ... Whole-cell recordings were acquired at 20 kHz and lowpass filtered at 2 kHz using a Multiclamp 700B amplifier and Digidata 1440A digitizer (Molecular Devices, San Jose, CA, USA). Neuronal intrinsic excitability (input/output curve ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... The plate was placed into a 37°C CO2 conditioned incubator for 30 min before GFP-β-arrestin-2 or rGFP-mini-Gαsi fluorescence levels were measured with a SpectraMax M5 fluorescence plate reader (Molecular Devices, San Jose, California, USA). For β-arrestin-2 experiments ...
-
bioRxiv - Physiology 2020Quote: ... in the presence of GABAA and GABAB receptor blockers (10 µM gabazine and 2 µM CGP55845, respectively; 30-34°C; Multiclamp 700B amplifier (Molecular Devices, San José, California, USA); 5 kHz low-pass filter ...
-
bioRxiv - Biochemistry 2024Quote: ... Kinetics of 4-methylumbelliferone release from fluorogenic substrates by glycosidases was recorded as an increase in fluorescence for 2 hours at 37°C using FilterMax™ F5 microplate reader (Ex: 360 nm, Em: 430 nm, Molecular Devices, San Jose, CA). The resulting concentration of 4-methylumbelliferone was determined using a calibration curve ...
-
bioRxiv - Physiology 2023Quote: ... All assays were performed in duplicate on 96 wells plate with an equal quantity of purified protein into each well (200 µg and 2 µg for cytosolic and mitochondrial fractions respectively) and read on a SpectraMax Microplate reader (Molecular Devices, San Jose, CA, USA).
-
bioRxiv - Neuroscience 2024Quote: ... and signals were low-pass filtered at 2 kHz and digitized at 10 kHz using an Axon Digidata 1550B analog-to-digital board (Molecular Devices, San Jose, CA, USA).
-
bioRxiv - Neuroscience 2021Quote: ... Digidata 1322 A/D converter and pClamp software (Molecular Devices, USA). Recordings were not corrected for the liquid junction potential ...
-
bioRxiv - Biophysics 2024Quote: ... sampled at 50 kHz (Digidata1440 A/D, Molecular Devices Co., CA) and stored in a computer (pClamp11.1 ...
-
bioRxiv - Neuroscience 2021Quote: ... and low-pass filtered (3 kHz) and digitized (3 kHz) with a Digidata 1440A analog-to-digital converter (Molecular Devices) using the pClamp10 software (Molecular Devices).
-
bioRxiv - Neuroscience 2023Quote: Organoids were assayed using the FLIPR Calcium 6 assay kit (Molecular Devices). Briefly ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass pipettes (3–4 MΩ, Molecular Devices) filled with internal solution (295–305 mOsm ...
-
bioRxiv - Microbiology 2020Quote: Binding affinities of S-D4 with SARS-CoV-2 S-RBD were performed by BLI on an Octet RED96 (Molecular Devices LLC, San Jose, CA, USA) using AR2G biosensors ...
-
bioRxiv - Microbiology 2021Quote: ... Growth was determined by measuring the optical density (OD 595 nm) of the suspensions every 2 h using a microplate reader (SpectraMax M2, Molecular Devices, LLC, San Jose, CA, USA).
-
bioRxiv - Biochemistry 2021Quote: ... Data were acquired at a holding potential of −60 mV using an Axopatch 200B amplifier and a Digidata 1322A digitizer run through pClamp 9 software (Molecular Devices; San Jose, CA). Currents were low-pass filtered at 1-5 kHz and digitized at 10-20 kHz.
-
bioRxiv - Physiology 2022Quote: Single IP3R channel potassium currents (ik) were measured in the on-nucleus patch clamp configuration using pCLAMP 9 and an Axopatch 200B amplifier (Molecular Devices, Sunnydale, CA, USA). Pipette solution contained 140 mM KCl ...
-
bioRxiv - Neuroscience 2021Quote: ... digitized using a Digidata 1440A A-D board (Molecular Devices, Sunnyvale, CA) and analyzed using pClamp10 software (Molecular Devices ...
-
bioRxiv - Neuroscience 2022Quote: ... and digitized with an A/D converter (Digidata 1550, Molecular Devices, USA). Data were acquired at sampling rate of 10 kHz and were further down sampled to 1KHz using MATLAB for all the further analysis of state space ...