Labshake search
Citations for Molecular Devices :
601 - 650 of 831 citations for 1 5 Bromo 1 2 Trimethylsilyl Ethoxy Methyl 1H Pyrrolo 2 3 B Pyridin 3 Yl Ethanone since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... band-pass filtered (1-3000 Hz) and sampled at 10 kHz with a Digidata 1440A acquisition board (Molecular Devices). Spikes were sorted using Spike 2 software (CED ...
-
bioRxiv - Genetics 2022Quote: ... Absorbance at 420 nm was measured every minute for 1 hour on a SpectraMax M2 Microplate Reader (Molecular Devices). Measures taken between 20 and 35 minutes (linear range ...
-
bioRxiv - Physiology 2022Quote: BAT SNA was amplified (x 5,000–10,000) and filtered (1–300 Hz) by a CyberAmp 380 amplifier (Molecular Devices). All the physiological variables were digitized and recorded to a personal computer using Spike 2 software (version 7.10 ...
-
bioRxiv - Neuroscience 2024Quote: ... Responses to repetitive 1 s light stimuli were recorded using Axosope 10.7 and analyzed using Clampfit 10.7 software (Molecular Devices) and Igor Pro 6.37 ...
-
bioRxiv - Neuroscience 2023Quote: ... BAT SNA was amplified (× 5,000 to 10,000) and filtered (1 to 300 Hz) using a CyberAmp 380 amplifier (Molecular Devices). All the physiological variables were digitized and recorded to a personal computer using Spike2 software (version 7.10 ...
-
bioRxiv - Neuroscience 2021Quote: ... and digitized at 5 kHz with Digidata 1440 and Clampex 10 software (Molecular Devices). mEPSCs were detected by fitting to a variable amplitude template using pClamp 10 analysis software ...
-
bioRxiv - Neuroscience 2021Quote: ... filtered at 5 kHz and digitized at 10 kHz (Multiclamp 200B; Molecular Devices, USA). Data were acquired using Igor Pro with NIDAQ tools (Wavemetrics ...
-
bioRxiv - Neuroscience 2024Quote: ... digitized at 5 kHz and recorded using the pCLAMP 9 program (Molecular Devices, USA). The inhibitory effect of the studied compounds was analyzed at steady-state conditions using the Clampfit 10.7 program (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... 30 consecutive action potentials were recoded every 5 seconds using Clampex 10.6 (Molecular Devices) at 100 kHz sampling rate and filtered at 2 kHz using a MultiClamp 700B amplifier (Molecular Devices) ...
-
bioRxiv - Physiology 2023Quote: ... and digitized at 5 kHz using a Digidata 1440A digitizer (Axon CNS, Molecular Devices). 61,62 Patch pipettes were made from borosilicate glass capillary tubes ...
-
bioRxiv - Microbiology 2023Quote: ... 5% CO2 before live cell imaging was done by (ImageXpressMicro-confocal, Molecular Devices, USA) equipped with 4x S Fluor lens in two channels ...
-
bioRxiv - Neuroscience 2021Quote: ... low pas filtered at 1 kHz and digitized at a sampling rate of 20 kHz using Digidata 1440A (Molecular Devices). Data was recorded on a PC using pClamp 10.6 (Molecular Devices ...
-
bioRxiv - Neuroscience 2020Quote: ... Data were low-pass filtered at 1 kHz and digitized at 10 kHz with a digitizer (Digidata 1440; Molecular Devices). Series resistance was monitored and cells that displayed > 20% change over the duration of recording were excluded.
-
bioRxiv - Neuroscience 2021Quote: ... The digital low-pass 8-pole Bessel filter with 1 kHz 3dB cut-off was applied in Clampfit 10.7 (Molecular Devices) before the current amplitudes were determined ...
-
bioRxiv - Neuroscience 2022Quote: ... electrophysiological traces were low-pass filtered offline with an 8-pole RC filter at 1 kHz using ClampFit 10.7 (Molecular Devices). Four distinct parameters were analyzed from each choline-evoked response ...
-
bioRxiv - Genetics 2021Quote: ... Optical density data were collected every 1 hour for 72 h total using a plate reader (SpectraMAX 384, Molecular Devices). Growth kinetic parameters were calculated using the MATLAB code OCHT reported by de Mello et al ...
-
bioRxiv - Neuroscience 2021Quote: ... Mechanical stimulation in cell attached patches was performed using a high-speed pressure clamp (Besch et al., 2002) (HSPC-1, ALA Scientific) controlled by pClamp 11.1 software (Molecular Devices) as described earlier (Borbiro et al. ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were filtered with a 1 kHz bezel filter and sampled at 20 kHz using Axon pClamp10 software (Molecular Devices).
-
bioRxiv - Neuroscience 2024Quote: ... Signals were filtered with a 1 kHz bezel filter and sampled at 20 kHz using Axon pClamp10 software (Molecular Devices).
-
bioRxiv - Neuroscience 2024Quote: ... sEPSC recordings were filtered post-hoc with a 1 kHz low-pass Bessel 8-pole filter in Clampfit (Molecular Devices).
-
bioRxiv - Neuroscience 2024Quote: ... low pas filtered at 1 kHz and digitized at a sampling rate of 20 kHz using Digidata 1440A (Molecular Devices). Data was recorded on a PC using pClamp 10.6 (Molecular Devices ...
-
bioRxiv - Neuroscience 2024Quote: ... The pressure waveform was digitized at 1 kHz using a MiniDigi 1B digitizer (Axon Instruments) and recorded with AxoScope 10.7 (Molecular Devices). Breaths were detected in Python 3.12 using a method similar but not identical to that described for event detection in the EEG ...
-
bioRxiv - Immunology 2024Quote: ... The reaction was then stopped with 1 N H2SO4 and the plate was read using a SpectraMax i3 (Molecular Devices) at wavelengths of 450 nm and 570 nm.
-
bioRxiv - Neuroscience 2024Quote: ... and emission at 520 nm was imaged with a Hamamatsu OrcaFlash 4.0LT camera (1 fps, 100 ms exposure) and recorded using MetaFluor (Molecular Devices). The baseline intracellular Ca2+ concentration was monitored for 120Ls before adding any other stimuli and a Krebs-based solution in which the KCl concentration was increased to 45 mM by iso-osmotic substitution of NaCl was used at the end of each experiment to identify DRG neurons ...
-
bioRxiv - Neuroscience 2024Quote: ... The frequency of sIPSCs for 1 min of pre- and post-NA application were quantified using Clampfit version 10.7 (Molecular Devices). We quantified averaged RMP for 1 min of pre- and post-drug application ...
-
bioRxiv - Neuroscience 2020Quote: Spontaneous IPSCs were identified in 5 min recording epochs using Clampfit (version 10.7, Molecular Devices) in conjunction with a template pattern search (generated from examples of sIPSC rise profiles and peak currents recorded from control cultured hippocampal neurons at the same temperature) ...
-
bioRxiv - Biochemistry 2022Quote: ... Fluorescence was measured every 5 s with a SpectraMax Gemini EM Microplate Reader (Molecular Devices) with excitation at 365 nm and emission at 407 nm ...
-
bioRxiv - Neuroscience 2021Quote: ... low-pass filtered at 5 kHz and subsequently analyzed using Clampfit 10.7 Software (Molecular Devices). Linear leak and capacitive currents were subtracted online using the P/4 protocol (20ms I-V protocol ...
-
bioRxiv - Cell Biology 2024Quote: ... Luminescence was monitored with 5 min interval at 37°C using SpectraMax iD5 (Molecular Devices). Data was normalized to the initial luminescence value after adding the drugs.
-
bioRxiv - Molecular Biology 2021Quote: ... by 1:20 dilution with a series of commercially available pH buffers (HYDRION) using a SpectraMax-M5 plate reader (Molecular Devices) to read out fluorescence ...
-
bioRxiv - Neuroscience 2022Quote: ... filtered at 3 kHz and digitized at 10 kHz using an EPC-10 patch-clamp amplifier with PatchMaster v2x73 software (batch 1) or MultiClamp 700B amplifier (Molecular Devices) with pClamp 10 software (batch 2) ...
-
bioRxiv - Developmental Biology 2020Quote: ... A voltage-clamp protocol was employed to record whole-cell currents with and without extracellular divalent cations in response to a voltage ramp from −120 to 60 mV (1 second interval) using an Axopatch 200B amplifier with pCLAMP10 software (Molecular Devices) as previously described [71 ...
-
bioRxiv - Neuroscience 2020Quote: ... The signal for all voltage-clamp recordings was filtered at 1 kHz and digitized at 10 kHz with a digitizer (Molecular Devices). For voltage-clamp recordings ...
-
bioRxiv - Biophysics 2021Quote: ... The reaction was monitored at 650 nm (turbidity due to precipitation of the product) for 1 h at 25 °C using a Spectramax i3 (Molecular Devices). Statistical analysis was performed using unpaired t-test in Prims 9.0.
-
bioRxiv - Synthetic Biology 2021Quote: ... Reactions were monitored at 340 nm for 1 hour (30s per read) using a SpectraMax Plus 384 microplate reader (Molecular Devices). NADH concentrations were determined by its extinction coefficients ...
-
bioRxiv - Microbiology 2020Quote: ... Fluorescence was measured every 60s for 1 hour after addition of virus on a FilterMax F5 multimode microplate reader (Molecular Devices). Enzyme Vmax and Km was calculated using Prism software (GraphPad).
-
bioRxiv - Microbiology 2021Quote: ... 2021.Infected cells were imaged for 72 h with 1 h intervals with a 40x objective with the ImageXpress Micro XL high-content microscope (Molecular Devices). Different parameters ...
-
bioRxiv - Microbiology 2021Quote: ... Protein concentrations were determined using the corresponding extinction coefficient at 280 nm (ExPASy, ProtParam tool) and measured in a 1 ml quartz cuvette (Hellma Analytics) using a SpectraMax M2 spectrophotometer (Molecular Devices). Proteins were long-term stored at -80 °C in 10% glycerol.
-
bioRxiv - Biophysics 2021Quote: ... The analog current signal was low-pass filtered at 1 kHz (Bessel) and digitized at 10 kHz with a Digidata 1550A digitizer (Molecular Devices). Digitized data were recorded on a computer using the software pClamp (Molecular Devices ...
-
bioRxiv - Biophysics 2022Quote: ... Data were filtered at 1-3kHz and digitized at 10kHz using a Digidata 1321A interface board and pCLAMP 10 software (Axon; Molecular Devices). Microelectrode resistances were 0.2–0.8MΩ when filled with 3 M KCl ...
-
bioRxiv - Immunology 2020Quote: ... and the reactions were stopped by adding 1 M H2SO4 before measuring absorbance at 450 nm with a Spectramax Paradigm plate reader (Molecular Devices).
-
bioRxiv - Immunology 2020Quote: ... and the reactions were stopped by adding 1 M H2SO4 before measuring absorbance at 450 nm with a Spectramax Paradigm plate reader (Molecular Devices).
-
bioRxiv - Neuroscience 2021Quote: ... The signal for voltage-clamp recordings was filtered at 1 kHz and digitized at 10 kHz with a digitizer (Molecular Devices). Stimulus generation and data acquisition were performed using pClamp (Molecular Devices).
-
bioRxiv - Neuroscience 2020Quote: ... the recorded unit was stimulated by a current pulse of 250ms long (50 % duty cycle, 1-10 nA) sent through the recording electrode by axoClamp 2B (in bridge mode; Molecular Devices). Then ...
-
bioRxiv - Neuroscience 2022Quote: ... Membrane responses to 1 s current injection between 0-700 pA (100 pA increment) were collected using an Axopatch-200B amplifier (Molecular Devices). Paired pulse optogenetic and electrical stimulation (20 Hz every 30 s ...
-
bioRxiv - Cell Biology 2022Quote: ... Data was Bessel filtered online at 1 kHz and single channel currents were analyzed offline using ClampFit analysis module of pCLAMP 10 software (Molecular Devices).
-
bioRxiv - Synthetic Biology 2020Quote: ... Purified proteins were quantified by measuring absorbance at 280 nm in a 1-cm quartz cuvette with a SpectraMax Plus384 microplate spectrophotometer (Molecular Devices), and applying Beer-Lambert’s law using extinction coefficients calculated with the ProtParam tool (https://web.expasy.org/protparam/).
-
bioRxiv - Synthetic Biology 2021Quote: ... Samples were measured via kinetic measurements (1 measurement/min) for a total of 30 minutes at 405 nm using a SpectraMax iD3 spectrophotometer (Molecular Devices).
-
bioRxiv - Microbiology 2020Quote: ... Single cell ionic currents were measured in the perforated patch clamp configuration (100 μgmL−1 amphotericin) at room temperature (21–23 °C) using an IonWorks Quattro instrument (Molecular Devices). The internal solution contained (mM) ...
-
bioRxiv - Immunology 2020Quote: ... The reaction was stopped with 1% HCl and absorbance at 450 nm was read with a SpectraMax plate reader (Molecular Devices). SoftMax Pro v5.3 was used to calculate log area-under-the-curve (AUC ...