Labshake search
Citations for Electron Microscopy Sciences :
1 - 12 of 12 citations for Cytomegalovirus gH Pentamer Complex since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2020Quote: ... each complex was deposited on plasma cleaned CF-400 grids (EMS) and stained using methylamine tungstate (Nanoprobes) ...
-
bioRxiv - Biochemistry 2022Quote: 3 µl of ~ 1.5 µM (0.75 mg/ml) of the complex was applied to freshly glow discharged quantifoil 300 mesh R 1.2/1.3 grids (EMS) and plunge frozen into liquid ethane using a Thermo Fisher Vitrobot Mark IV with conditions of 4 °C ...
-
bioRxiv - Biophysics 2022Quote: ... 3 μl of 0.6–0.9 mg/ml of freshly purified wt HOPS complex were applied onto glow-discharged CF grids (R1.2/1.3) (EMS) and immediately plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: The complex was vitrified on QUANTIFOIL® holey carbon grids (400-mesh, copper, R1.2/1.3, Electron Microscopy Sciences) using a FEI Vitrobot Mark IV (FEI ...
-
bioRxiv - Microbiology 2021Quote: ... 3.5 µl of the complex solution were deposited onto a C-flat 1.2/1.3-3C holey carbon copper grid (Electron Microscopy Sciences) that had been freshly glow-discharged for 1 min at 20 mA using a PELCO easiGLOW (Ted Pella) ...
-
bioRxiv - Biophysics 2022Quote: ... A 3.5 μL sample containing the complex (1 mg/ml) was applied to a glow-discharged UltraAuFoil grid (R1.2/1.3, mesh 300) (Electron Microscopy Sciences), and then blotted and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 µl of 1 mg/ml 70S ribosome RafH complex was applied on a glow discharged 300 CF300-Cu grids (EMS), the excess sample was blotted ...
-
bioRxiv - Biochemistry 2023Quote: Three microliters of the freshly purified complex were applied to a plasma-cleaned C-flat holy carbon grid (1.2/1.3, 400 mesh, Electron Microscopy Sciences) with 20 s glow discharge using air and flash-frozen in liquid ethane with a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2024Quote: The specimen was vitrified using 3 μL of freshly purified BasC-Nb71 complex in 0.17% DM applied to glow-discharged Quantifoil R 0.6/1 Cu 300 mesh grids (Electron Microscopy Sciences), at a concentration of 2.2 mg/ml ...
-
bioRxiv - Molecular Biology 2020Quote: 3 µL of NT-NTR1-Gαi1β1γ1-cND complex at a concentration of 0.02 mg/mL was applied onto a glow-discharged continuous carbon grid (Electron Microscopy Sciences, Inc.). After two minutes of adsorption ...
-
bioRxiv - Bioengineering 2021Quote: ... ∼5 μL of each sEV-particle complex was left to adhere onto formvar carbon coated copper Grid 200 mesh (Electron Microscopy Sciences) for 5 mins followed by 5 mins of negative staining with 2% aqueous uranyl acetate ...
-
bioRxiv - Immunology 2022Quote: ... and 3 µL of the complex/detergent mixture was immediately applied to QuantiFoil 300 mesh 1.2/1.3 grids (Electron Microscopy Sciences, Hatfield, PA) that had been freshly glow discharged with PELCO easiGLOW (Ted Pella ...