Labshake search
Citations for World Precision Instruments :
251 - 300 of 392 citations for 2 4 Dimethyl 4' 4 methylpiperazinomethyl benzophenone since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2024Quote: ... The electrical resistance of cell monolayers was measured on day 4 (before stimulation) and day 7 (after 3 days of stimulation) using an EVOM2 epithelial Volt/ Ohm meter (World Precision Instruments, FL, USA). The resistance of cell monolayers was corrected by subtracting the resistance of wells without cells and normalized by multiplying by the effective well surface area to provide transepithelial electrical resistance (TEER ...
-
bioRxiv - Neuroscience 2024Quote: ... A Hamilton syringe (Hamilton 7635-01) was filled with either PBS or C9-ASO at 50 ng/μL and attached to a microinjection pump (World Precision Instruments Micro 4) on a stereotactic arm ...
-
bioRxiv - Neuroscience 2023Quote: ... and 26-gauge needle (Hamilton) at a flow rate of 100 nl/min driven by a microsyringe pump controller (World Precision Instruments, model Micro 4). The syringe needle was left in place for 10 min and was completely withdrawn 17 min after viral delivery ...
-
bioRxiv - Genetics 2023Quote: ... 0.5nl of the mixtures were directly injected into the yolk of freshly layed zygotes using a glass capillary needle [TW120-4) (Kwik-Fil, World Precision Instruments, Inc., Hertfordshire, UK)] with the help of a pedal controlled microinjector (PV820 Pneumatic PicoPump ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes (10-15 MΩ) were pulled from borosilicate capillary glass (BF150-86-10, Sutter Instruments, Novato, USA or 1B150F-4, World Precision Instruments, Sarasota, USA) in a horizontal pipette puller (P-1000 Micropipette puller ...
-
bioRxiv - Neuroscience 2024Quote: ... plasmid was delivered using a glass pipette at a flow rate of 50 nl/min driven by a microsyringe pump controller (World Precision Instruments, model Micro 4). The syringe needle was left in place for 10 min and was completely withdrawn 17 min after viral delivery ...
-
bioRxiv - Neuroscience 2021Quote: ... Extracellular recordings were obtained using tungsten electrodes (TM31C40KT, 4-MΩ impedance at 1 kHz or TM31A50KT, 5-MΩ impedance at 1 kHz; World Precision Instruments Inc., Sarasota FL, USA). All recordings were pre-amplified in the DC mode ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... SM preparations were fixed between a stationary stainless steel hook and an isometric force transducer (AE 801, SensoNor A/S, Norten, Norway) coupled to an AD converter Lab-Trax 4/16 (World Precision Instruments, Inc., Sarasota, FL, USA). The data were continuously recorded using DataTrax2 (World Precision Instruments ...
-
bioRxiv - Bioengineering 2023Quote: ... Using 2 syringe pumps (WPI, AL-1000), an interstitial flow was created by applying different flow rates (Q1=334 μl min-1 and Q2=10 μl min-1 ...
-
bioRxiv - Neuroscience 2023Quote: ... with 35G bevelled needles (WPI, NF35BV-2) was filled ...
-
bioRxiv - Neuroscience 2020Quote: ... Infusions were delivered via 2 μl syringe (Hamilton, Neuros) controlled by a microsyringe pump (World Precision Instruments, UMP3-2). Infusion rate was ~0.11 μl/min ...
-
bioRxiv - Neuroscience 2020Quote: ... Infusions were delivered via 2 μl syringe (Hamilton, Neuros) controlled by a microsyringe pump (World Precision Instruments, UMP3-2). Infusion rate was ~0.11 μl/min ...
-
bioRxiv - Neuroscience 2024Quote: ... 2-3 injections of 300nL of virus were made using a beveled glass micropipette at a depth of ∼300 μm to target layer 2/3 of the cortex at a rate of 65 nl/min with a microsyringe pump (UMP3T-2, WPI). For imaging experiments ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (1.5 – 2 MΩ) (World Precision Instruments) were made using a pipette puller (Narishige ...
-
Polyunsaturated Fatty Acid - mediated Cellular Rejuvenation for Reversing Age-related Vision DeclinebioRxiv - Molecular Biology 2024Quote: ... by SilFlex tubing (World Precision Instruments; SILFLEX-2), was advanced through the tunnel ...
-
bioRxiv - Neuroscience 2021Quote: ... a volume of 300 nL of AAV9-cFos-tTa + TRE-EYFP viral cocktail was bilaterally injected at 200 nL/min using a micro-infusion pump for each coordinate (2×300 nL for dDG and 2×300 nL for BLA) (UMP3; World Precision Instruments). After injection was complete ...
-
bioRxiv - Developmental Biology 2021Quote: ... The microelectrode and a reference electrode (WPI, DRIREF-2) were then mounted onto the micromanipulator (Narishige MO-202D ...
-
bioRxiv - Neuroscience 2023Quote: ... A 2 MΩ tungsten electrode (World Precision Instruments, TM33A20) driven by a Sutter manipulator was inserted into the depth of TG (around 5 - 6 mm below brain surface) ...
-
bioRxiv - Neuroscience 2023Quote: ... and 35G NanoFil beveled needle (WPI; Catalog# NF35BV-2). The volume of AAVs was 500-1000 nL at the rate 50-100 nL per minute ...
-
bioRxiv - Neuroscience 2023Quote: ... fit with a 36G beveled needle (NF36BV-2, WPI). A high-titre solution of viral vector (AAV9-syn-jGCaMP7f-WPRE ...
-
bioRxiv - Neuroscience 2024Quote: ... or a microinjector pump (World Precision Instruments, UMP3T-2) with an attached 10-μL NanoFil syringe (World Precision Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... A 34G Beveled needle (World Precision Instruments; NF34BV-2) attached to a 10 μl Hamilton syringe was used to inject one microliter of virus per site at a rate of 0.095 μl/min ...
-
bioRxiv - Bioengineering 2020Quote: ... 2×104 sGFP sender and 2×104 αGFP receiver cells were seeded into 35-mm FluoroDish Cell Culture Dishes (World Precision Instruments, FD35-100) and immediately imaged under a DeltaVision OMX (GE Healthcare ...
-
bioRxiv - Neuroscience 2022Quote: ... through a 33G beveled needle (World Precision Instruments, # NF33BV-2), controlled by a micro-syringe pump (World Precision Instruments ...
-
Social Regulation of Egg Size Plasticity in the Honey Bee is Mediated by Cytoskeleton Organizer Rho1bioRxiv - Evolutionary Biology 2022Quote: ... coupled with a 35G needle (NF35BV-2; World Precision Instruments). Injected queens were given time to recover and placed back into their original colonies ...
-
bioRxiv - Neuroscience 2021Quote: ... with a 33-gage beveled Nanofil needle (NF33BV-2, WPI). The syringe was mounted into a motorized microinjector (UMP3T-2 ...
-
bioRxiv - Neuroscience 2023Quote: ... a Nanofil 33-gauge needle (World Precision Instruments, #NF33BV-2) was slowly inserted into the CA1 region (AP ...
-
bioRxiv - Neuroscience 2023Quote: ... Females: scaled*0.95) using a 33g needle (NF33BV-2, WPI). During the same surgery ...
-
bioRxiv - Neuroscience 2024Quote: ... and a microinjection syringe pump (UMP3T-2 World Precision Instruments). Animals received 250 µL of saline for post-surgery hydration.
-
bioRxiv - Neuroscience 2020Quote: ... were applied with a glass pipette (2-3 μm diameter) positioned 20 to 30 μm away from the soma and connected to a picospritzer (World Precision Instruments, adjusted to ~2 psi). All electrophysiological recordings were extracted using Clampfit (Molecular Devices ...
-
bioRxiv - Neuroscience 2021Quote: ... The syringe was mounted into a motorized microinjector (UMP3T-2, WPI) that was held by a manipulator (model 1460 ...
-
bioRxiv - Neuroscience 2023Quote: ... The microsyringe was mounted into a motorized microinjector (UMP3T-2, WPI) that was held by a manipulator (Model 1460 ...
-
bioRxiv - Neuroscience 2023Quote: ... The syringe was mounted on a motorized microinjector (UMP3T-2, WPI) that was attached to a manipulator (Model 1460 ...
-
bioRxiv - Neuroscience 2024Quote: ... using the STX-2 electrode system (World Precision Instruments, Berlin, FRG). The final TEER values were multiplied by the filter surface area ...
-
bioRxiv - Genetics 2023Quote: ... OCT was performed at 2- and 3-weeks post-injection (WPI), then 1- ...
-
bioRxiv - Molecular Biology 2024Quote: ... 35G (NF35BV-2) needle and an UMP3 ULTRAMICROPUMP microinjector from WPI, USA ...
-
bioRxiv - Neuroscience 2021Quote: ... The Hamilton syringe was mounted into a motorized microinjector (UMP3T-2, WPI) that was held by a manipulator (model 1460 ...
-
bioRxiv - Neuroscience 2023Quote: ... AAV-containing solution was infused using a 34-gauge needle (NF34BV-2, WPI) connected to a 10µL Nanofil Syringe (NANOFIL ...
-
bioRxiv - Neuroscience 2022Quote: ... and/or Day 2 of subculture using the EVOM2 voltohmmeter (World Precision Instruments) with STX2 chopstick electrodes (World Precision Instruments) ...
-
bioRxiv - Genetics 2023Quote: ... 2 nl of this mix using a pneumatic system (pneumatic pico pump, WPI) and glass capillaries (Zebrafish-injection-pipettes blunt ...
-
bioRxiv - Neuroscience 2023Quote: ... Isoflurane (1-2%) mixed with oxygen was delivered through a nose cone (WPI). Buprenex® (buprenorphine ...
-
bioRxiv - Physiology 2022Quote: ... pulled from glass tubes (1.12 mm inner / 2 mm outer diameter, World Precision Instruments) and bent at 30 ° to allow near-parallel alignment of the fibres with the bottom of the experimental chamber ...
-
bioRxiv - Neuroscience 2023Quote: ... Bilateral infusions were achieved using a 35-gauge needle (World Precision Instruments NF35BV-2) and a 10 μL Hamilton Syringe (World Precision Instrument NANOFIL) ...
-
bioRxiv - Neuroscience 2020Quote: ... driven by a digital Micro2T controller (Model UMP3T-2; World Precision Instruments, Sarasota, FL, USA). After each injection ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Anterior chambers were cannulated with 33-gauge beveled needles (NanoFil, NF33BV-2, World Precision Instruments) attached to micro-manipulators and equilibrated for 30 minutes at 9 mmHg ...
-
bioRxiv - Cancer Biology 2023Quote: ... which was experimentally validated using a set Ca2+ calibration buffers (World Precision Instruments, Calbuf-2). Rates of Ca2+ uptake were determined by fitting a single exponential from the initial peak after Ca2+ addition (T = 400 sec ...
-
bioRxiv - Neuroscience 2024Quote: ... The filling needle was replaced with a 35-gauge needle (World Precision Instruments, #NF35BV-2), and the syringe was secured to a micromanipulator (Model Kite-L ...
-
bioRxiv - Microbiology 2023Quote: ... and 14 Trans-epithelial electrical resistance (TEER) was measured (EVOM-2 voltohmmeter, World Precision Instruments) 10 min after medium change ...
-
bioRxiv - Neuroscience 2023Quote: Eyes were initially punctured with a beveled needle (NF36BV-2, NanoFil Needles, World Precision Instruments) in the pars plana site that is posterior from the limbus of the eye [41 ...
-
bioRxiv - Cell Biology 2024Quote: STX4 EVOM electrodes connected to an EVOM 2 electrical impedance reader (both World Precision Instruments) were used to measure electrical resistance in ohms (Ω) ...