Labshake search
Citations for Illumina :
351 - 400 of 1781 citations for tert Butyl 2 chloro 5H pyrrolo 3 4 b pyridine 6 7H carboxylate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2024Quote: ... The paired-end reads of 150 bp were generated in an S4 flowcell with v1.5 sequencing chemistry on a NovaSeq-6 000 platform (Illumina Inc.). Read quality was checked by FastQC tool v0.11.9 ...
-
bioRxiv - Bioengineering 2023Quote: ... pair-end single index sequencing parameters were adjusted to 101/6/0/86 (as opposed to 74/6/0/86) to effectively utilize the capabilities of the NovaSeq 200 cycle reagent kit (Illumina). To demultiplex each sample and to generate the matrix of transcript counts in each cell ...
-
bioRxiv - Cell Biology 2022Quote: ... Multiplexed libraries for the 1.5 h samples were generated using the Lexogen QuantSeq 3’ mRNA-Seq Library Prep Kit and for the 6 h samples using TruSeqHT Stranded Total RNA Library Prep protocol (Illumina).
-
bioRxiv - Microbiology 2023Quote: ... Multiplexing of sgRNA challenge screens in BCBL-1 was performed utilizing 6-bp indexes and sequenced on a single lane of a HiSeq4000 (Illumina) using 50bp single-end (SE ...
-
bioRxiv - Plant Biology 2023Quote: Prepared libraries were pooled and diluted to 6 pM for TruSeq Paired End v4 DNA clustering on one single flow cell lane using a cBot device (Illumina). Final sequencing was carried out on an Illumina HiSeq 2500 platform using 126 ...
-
bioRxiv - Microbiology 2020Quote: ... Samples were sequenced using the MiSeq 2×250 bp and HiSeq 2×150 bp paired-end read technology (Illumina, San Diego, CA, USA) as previously described [78] ...
-
bioRxiv - Genomics 2024Quote: ... and sequenced across three lanes of a HiSeq or pooled for sequencing on a NovaSeq S1 using 2×75 (HiSeq) or 2×101 (NovaSeq) read lengths (Illumina, San Diego, CA). Variant calling and neoantigen prediction were performed as described previously (22,23).
-
bioRxiv - Evolutionary Biology 2020Quote: ... The blunt-ended double stranded cDNA was 3’adenylated and Illumina single indexed adapters (Illumina) were ligated ...
-
bioRxiv - Microbiology 2020Quote: ... 3’ adapter sequences from the Illumina TruSeq Small RNA Library Preparation Kit (Illumina, RS-200) were ligated onto the dsRNA species by mixing together 1 μl of adapter with 1 μg dsRNA in a 6 μl reaction and heated at 70°C for 2 minutes ...
-
bioRxiv - Genomics 2022Quote: ... An “A” base was then added to the 3’ end and the adaptor from Illumina was ligated only to one end of the resultant dsDNA as the other end contained a 5’ overhang introduced by the N9 primer ...
-
bioRxiv - Neuroscience 2021Quote: ... followed by A-tailing and ligation at the 3’ ends with paired-end adaptors (Illumina) with a single “T” base overhang ...
-
bioRxiv - Cancer Biology 2021Quote: Four 3’ PCR primers were used each containing a unique index (underlined) recognized by Illumina:
-
bioRxiv - Neuroscience 2023Quote: ... using the combination of primer Ad1_noMX (5’ AATGATACGGCGACCACCGAGATCTACACTCGTCGGCAGCGTCAGATGTG 3’) and the Nextera Index Kit (Illumina) primer N701-N706 ...
-
bioRxiv - Biochemistry 2023Quote: ... mRNA libraries were prepared using the QuantSeq 3’ mRNA-Seq Library Prep Kit FWD (Illumina). Quality of mRNA libraries was determined using Agilent Tape Station and mRNA was sequenced at 75 bp single read sequencing using NextSeq 500 (Illumina).
-
bioRxiv - Synthetic Biology 2022Quote: ... adding barcodes to identify the sample (primers P3-P15 in Supplementary Table 3, containing Illumina Nextera tagmentation adapters and ...
-
bioRxiv - Developmental Biology 2021Quote: ... 4 nM 10X scATAC-seq library was sequenced on a NextSeq500 platform (Illumina) using NextSeq 500/550 High Output Kit v2.5 (75 Cycles ...
-
bioRxiv - Developmental Biology 2021Quote: ... 4 nM 10X scRNA-seq libraries were sequenced on a NextSeq500 platform (Illumina) using NextSeq 500/550 High Output Kit v2.5 (150 Cycles ...
-
bioRxiv - Biophysics 2022Quote: ... The sequencing (Step 4) was performed using a Hi-Seq sequencer (Illumina, US) and the data was then filtered using the framing sequence ACAC with a quality score larger then 20 and analyzed (Step 5 ...
-
bioRxiv - Cell Biology 2023Quote: ... 4 ATAC-seq libraries were sequenced per lane in HiSeq 2500 System (Illumina) to generate paired-end 50-bp reads ...
-
bioRxiv - Microbiology 2024Quote: ... DNA from the V3-4 region was amplified using a primer set (Illumina, San Diego ...
-
bioRxiv - Genomics 2022Quote: ... SW-8046-2) from libraries prepared using the Nextera XT DNA kit (Illumina, Inc, San Diego, CA, and sequenced on Illumina HiSeq4000 (2×150 bp). WGS data was obtained from six C ...
-
bioRxiv - Cancer Biology 2022Quote: ... generating 2 × 75 base read pairs or on a NovaSeq 6000 generating 2 × 150 base read pairs using standard settings (Illumina, San Diego, CA, USA). BCL output from the sequencing platform was converted to FASTQ using Illumina’s bcl2fastq tool (versions 2.17 to 2.20 ...
-
bioRxiv - Genomics 2024Quote: SARS-CoV-2 genome sequencing was performed on samples that were SARS-CoV-2 RNA-positive using the COVIDSeq Test (Illumina, San Diego, CA, USA). Libraries were sequenced on the Illumina NextSeq2000 instrument using 2×109 paired end reads ...
-
bioRxiv - Molecular Biology 2020Quote: ... Sequencing (Illumina HiSeq 2500, 2 × 50 bp paired-end reads) was performed in the MSKCC Integrated Genomics Operation ...
-
bioRxiv - Plant Biology 2020Quote: ... MiSeq 2×250 bp sequencing (Illumina, San Diego, CA, USA) was performed at the University of Florida’s Interdisciplinary Center for Biotechnology Research.
-
bioRxiv - Microbiology 2020Quote: ... and submitted for 2-by 250-bp Miseq sequencing (Illumina) to the DNA Technologies and Expression Analysis Cores at the UC Davis Genome Center (supported by NIH Shared Instrumentation Grant 1S10OD010786-01).
-
bioRxiv - Microbiology 2021Quote: ... with 2 × 150 bp and a MiSeq reagent V2 (Illumina).
-
bioRxiv - Plant Biology 2023Quote: ... and paired-end sequenced (2×150bp) with a HiSeq3000 (ILLUMINA).
-
bioRxiv - Microbiology 2023Quote: Paired end 2×250 bp reads were generated from Illumina sequencing on a NovaSeq SP 250PE at the QB3 facility ...
-
bioRxiv - Microbiology 2024Quote: ... pooled and sequenced on MiSeq (Illumina, 2 x 250 bp) using the MiSeq reagent kit v2 (500 cycles).
-
bioRxiv - Microbiology 2022Quote: ... and further Mi-Seq 2×300 bp paired-end (Illumina) 16S rRNA sequencing of the V3 and V4 regions (23 ...
-
bioRxiv - Genomics 2023Quote: ... The library was sequenced on NovaSeq 6000 (Illumina, 2×151bp) following the manufacturer’s protocol for dual indexing.
-
bioRxiv - Genomics 2023Quote: ... The library was sequenced on NovaSeq 6000 (Illumina, 2×151bp) following the manufacturer’s protocol for dual indexing ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... and sequenced on a NovaSeq 6000 (Illumina, 2 × 150 bp) for a 6Gb coverage.
-
bioRxiv - Synthetic Biology 2024Quote: ... Library 2 was sequenced on a NovaSeq X Plus (Illumina) using a paired-end 300 cycle kit by Novogene ...
-
bioRxiv - Cancer Biology 2021Quote: ... The INA-6 cells were sequenced (18 million reads per sample) using the TruSeq Stranded mRNA library preparation kit from Illumina (#20020595) followed by 75bp single read sequencing on the Illumina Hiseq 4000 next machine ...
-
bioRxiv - Neuroscience 2021Quote: ... and 80 million reads for each of the 24 samples of 3xTg-AD and C57BL/6×129/Sv mice in a fraction of a sequencing lane on HiSeq2000 (Illumina, Inc) following the manufacturer’s protocol ...
-
Induction of Dopaminergic Neurons for Neuronal Subtype-Specific Modeling of Psychiatric Disease RiskbioRxiv - Neuroscience 2021Quote: ... RNA fragmentation was performed at 94°C for 6 minutes and 10 PCR cycles were used during library amplification with TruSeq single-index adapters (Illumina, #20020492). Final library concentrations were quantified with both Qubit fluorometric quantification (DNA dsDNA HS kit ...
-
bioRxiv - Cancer Biology 2024Quote: ... Individually indexed libraries were pooled and sequenced on an Illumina platform (see Supplemental Table 6) to depth of 200M PE reads following the manufacture’s protocols (Illumina, Hayward CA.).
-
bioRxiv - Cell Biology 2021Quote: ... and 3 cycles of PCR for incorporation of unique dual indices (NEBNext multiplex oligos for Illumina) to the final libraries ...
-
bioRxiv - Cancer Biology 2021Quote: ... Both libraries were prepared using the QuantSeq 3′ mRNA-Seq Library Prep Kit FWD from Illumina, following the standard protocol ...
-
Three Distinct Transcriptional Profiles of Monocytes Associate with Disease Activity in SSc PatientsbioRxiv - Genomics 2022Quote: ... Both full-length and 3’ RNA- seq libraries were sequenced on a NextSeq 500 instrument (Illumina) with 5-10 x 106 aligned reads per sample ...
-
bioRxiv - Cancer Biology 2022Quote: ... We diluted the final library to 3 nM concentration and used a HiSeq PE150 sequencer (Illumina) to perform the sequencing.
-
bioRxiv - Genomics 2021Quote: ... and dual-indexed 3’ digital gene expression (DGE) sequencing libraries were prepared using Nextera XT (Illumina). Libraries were sequenced on a NovaseqS4 or NovaseqS2 with a paired end read structure (R1 ...
-
bioRxiv - Genetics 2020Quote: ... 3 groups in total) and constructed using the Illumina TruSeq Stranded Small RNA Sequencing kit (Illumina) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2022Quote: ... and 3 μg of the product was processed using the TruSeq RNA Sample Preparation Kit (Illumina). Purification of mRNA was performed using polyT oligo-attached magnetic beads ...
-
bioRxiv - Genomics 2023Quote: scRNA-seq library preparation was performed using 10x Genomics Chromium 3’ single cell library protocol (Illumina) according to the manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2023Quote: ... 3’ RNA-seq (Bulk MARS-seq91,135) libraries were prepared and sequenced on a Novaseq 6000 (Illumina) at the Weizmann Crown Institute for Genomics ...
-
bioRxiv - Cell Biology 2022Quote: ... Paired- end single cell 3’ gene expression libraries were sequenced on a Novaseq 6000 System (Illumina) using a NovaSeq S1 flow-cell to a depth of at least 3.5 × 108 reads/timepoint.
-
bioRxiv - Microbiology 2024Quote: ... Sequencing was performed using the MiSeq Reagent version 3 kit on a MiSeq sequencer (Illumina, USA), at the Research and Production Center for Microbiology and Virology ...