Labshake search
Citations for Quantifoil Micro Tools :
1 - 23 of 23 citations for IL 10 Mouse CHO since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2022Quote: ... The IL-11Δ10/IL-11RαD1-D3/gp130D1-D3 complex (0.5 mg/mL) was blotted onto UltrAuFoil grids (R2/2, Quantifoil Micro Tools GmbH) that had been subjected to glow discharge (15 mA for 30 s) ...
-
bioRxiv - Biophysics 2022Quote: Eleven cryoEM grids were prepared by two people by adding 3 μL of mouse apoferritin (mApof, from Dr. Kikkawa’s lab) solution (8 mg/mL) to UltrAuFoil 1.2/1.3 grids (Quantifoil, Jena, Germany) immediately after plasma cleaning (Gatan Solarus II plasma cleaner ...
-
bioRxiv - Biochemistry 2022Quote: ... Solutions were adjusted to OD600≈10 and applied to carbon-coated holey copper grids (Quantifoil R2/1). Grids were glow-discharged for 30 s in oxygen/argon atmosphere of a plasma cleaner (Gatan Solarus 950 ...
-
bioRxiv - Biophysics 2023Quote: ... 10 µL of samples were placed on top of a glow-discharged Au200 R2/1 grids (Quantifoil) and incubated in a 100%-humidity controlled environment ...
-
bioRxiv - Cell Biology 2022Quote: Tfam+/− MEFs (TFAM Het MEF) and SV40 mouse embryonic fibroblasts (SV40 MEF) were cultured on R ¼ Carbon 200-mesh gold electron microscopy grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture using a Vitrobot Mark 4 (Thermo Fischer Scientific) ...
-
bioRxiv - Biochemistry 2021Quote: ... were applied to glow discharged (2.2×10-1 mbar for 20 sec) Quantifoil holey carbon grids (R2/1, 200 mesh, Quantifoil). The grids were plunge vitrified into a liquid ethane/propane mix using a Vitrobot Mark IV at 4 °C and 95% humidity ...
-
bioRxiv - Biochemistry 2019Quote: ... 4 μl of these samples were applied to glow discharged (2.2×10-1 mbar for 2×20sec) Quantifoil holey carbon grids (R2/1, 200 mesh, Quantifoil). The grids were plunge vitrified into a liquid ethane/propane mix using a Vitrobot Mark IV at 4 °C and 95% humidity ...
-
bioRxiv - Microbiology 2023Quote: A 3.0 μl sample solution containing 10 nm colloidal gold was applied onto a glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Cu grid ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... The proteins were incubated at 37°C and 200 rpms for 10 minutes on a microplate shaker (BioShake iQ; Quantifoil Instruments ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl of protein at a concentration of approximately 10 mg ml−1 were loaded onto glow-discharged holey carbon grids (Quantifoil Au 300 mesh R1.2/1.3 or Quantifoil Cu/Rh 300 mesh R1.2/1.3) ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... The proteins were incubated at 37°C and 200 rpms for 10 minutes on a microplate shaker (Quantifoil Instruments, Jena, Germany). Next ...
-
bioRxiv - Biophysics 2022Quote: ... 10 µl sample was applied onto a glow discharged copper grid coated with holey carbon (R 2/2; Quantifoil, Jena, Germany), and subsequently dipped onto 500 µl deionized H2O for 1 second to clear the sucrose ...
-
bioRxiv - Cell Biology 2020Quote: ... Samples were applied to freshly glow-discharged (Edwards S150B, 45 sec, 30-50 mA, 1,2kV, 10-2 mbar) copper holey carbon grids (Quantifoil, Cu-R1.2/1.3) under 100% humidity ...
-
bioRxiv - Biochemistry 2023Quote: ... Samples were applied to freshly glow-discharged (Edwards S150B, 45 s, 30−50 mA, 1.2 kV, 10−2 mbar) copper holey carbon grids (Quantifoil, Cu-R1.2/1.3) under 100% humidity at 4°C.
-
bioRxiv - Biochemistry 2023Quote: 4.5 µL of freshly mixed Nup98 condensate and capsid mixture with protein A-gold (10 nm) were applied onto a glow-discharged Quantifoil R2/2 copper grid (Quantifoil Micro Tools). The grid was blotted in the front for 2.5 s at 15 °C with 90% relative humidity and then plunged into liquid ethane using a Lecia EM GP device (Lecia Microsystem) ...
-
bioRxiv - Biochemistry 2020Quote: ... aliquots (3 μL) of the purified protein concentrated to ~ 10 mg/mL were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3). For KCC3-DIOA samples ...
-
bioRxiv - Cancer Biology 2020Quote: ... 3 μL of urease samples at 1.3 mg/mL with 1 mM BME or with 10 mM SHA were applied to freshly glow-discharged Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools, Germany). The grids were blotted for 4 seconds ...
-
bioRxiv - Microbiology 2022Quote: A 5 µl cell suspension containing 10 nm colloidal gold particles were deposited on the copper EM grids with holey carbon supported film (Quantifoil, 200mesh, R1/2). The EM grid were blotted with filter paper (Waterman ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μL of sample (10 μM EGFP in PBS) was deposited onto glow-discharged grids (Electron Microscopy Science and Quantifoil – see Table 1), prior to blotting the grids from the sample-side for 3 seconds.
-
bioRxiv - Biochemistry 2023Quote: EM grids were prepared at 5°C by loading 10 μL of the protein suspension (0.05 mg/mL) onto glow-discharged copper TEM grids with continuous 10–12 nm carbon film coating (300 mesh size; Quantifoil Micro Tools, Großlöbichau, Germany). Excess liquid was blotted off with a strip of filter paper after 45 s followed by staining with 10 μL 2% (w/v ...
-
bioRxiv - Biochemistry 2024Quote: ... or calpain-3-titin/I81-I83 (2mg/mL) from Superose 6 increase 10/300GL column chromatography was loaded onto glow-discharged holey carbon grids (Quantifoil 1.2/1.3 + 2 nm Carbon). The grids were blotted with filter paper for 2.5 secs at 22 °C and then immediately plunged into liquid ethane cooled by liquid nitrogen using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Neuroscience 2024Quote: ... Supernatant after centrifugation mixed with 10-nm gold beads solution (Aurion, cat # 25486) at 1:1 ratio was added to the mounted grid (Quantifoil R2/2 Cu 200 EM). No other chemicals or stimulation were applied prior to plunge freezing ...
-
bioRxiv - Biophysics 2021Quote: ... of purified CtenDNAV-II virons (10 mg ml-1) was deposited onto freshly glow-discharged holey carbon-coated copper grids (Quantifoil R 2/2, 300 mesh, copper) followed by 2 s of blotting in 100% relative humidity for plunge-freezing (Vitrobot Mark IV ...