Labshake search
Citations for Qiagen :
1 - 50 of 10000+ citations for Prostaglandin E2 PGE2 Multi Format ELISA Kit 5 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genetics 2021Quote: Multi-array ELISA was performed using the Multi-Analyte ELISArray Kit (Qiagen, Hilden, Germany) according to the manufacturer’s instructions ...
-
bioRxiv - Genetics 2020Quote: DNA was extracted using the BioSprint automated extraction protocol in plate format (QIAGEN), using a proteinase-K digestion and an RNase incubation to reduce RNA presence in genomic DNA ...
-
bioRxiv - Microbiology 2019Quote: ... using the 96-well-format MoBio PowerSoil Kit (MoBio Laboratories; Qiagen) following the manufacturer’s instruction ...
-
bioRxiv - Microbiology 2021Quote: ... burgdorferi B31-e2 expression strains using the DNeasy Blood and Tissue Kit (Qiagen). The open reading frame (lacking the putative lipoprotein signal sequence ...
-
bioRxiv - Neuroscience 2021Quote: Cytokine secretion assays were performed using Human Multi-Analyte ELISArray plate (Qiagen CMEH6321A). IL1β ...
-
bioRxiv - Biophysics 2020Quote: ... we carried out initial crystallization trials in 15-well hanging drop format using EasyXtal crystallization plates (Qiagen) and a crystallization screen that was designed to explore the chemical space around the crystallization conditions reported by Blomberg et al.15 Crystallization drops were prepared by mixing 1 μL of protein solution with 1 μL of the mother liquor ...
-
bioRxiv - Biochemistry 2023Quote: ... we carried out initial crystallization trials in 15-well hanging drop format using EasyXtal crystallization plates (Qiagen) and a crystallization screen that was designed to explore the chemical space around the crystallization conditions reported by Broom et al.14 Crystallization drops were prepared by mixing 1 μL of protein solution with 1 μL of the mother liquor and sealing the drop inside a reservoir containing an additional 500 μL of the mother liquor solution ...
-
bioRxiv - Microbiology 2020Quote: ... or in 96-well format with a QIAprep 96 Turbo miniprep kit (Qiagen). We performed 98°C BarSeq PCR protocol as described previously [63 ...
-
bioRxiv - Cancer Biology 2021Quote: ... The Multi-Analyte ELISArray Kit (Qiagen, Venlo, Netherlands; MEH-003A) was used according to the manufacturer’s instructions ...
-
bioRxiv - Pathology 2021Quote: Pre-spotted custom plates (96-well format) were designed to comprehend 89 different miRCURY LNA miRNA primers (Qiagen), three assays for small nuclear or nucleolar RNAs as reference candidates (SNORD44 ...
-
bioRxiv - Cancer Biology 2020Quote: ... Our panel of 88 target genes was prepared on a 96-well plate format with housekeeping genes and controls (RT2 PCR array, Qiagen). Expression was quantified on an ABI7500 real-time PCR machine (Applied Biosystems ...
-
bioRxiv - Microbiology 2019Quote: ... or in a 96-well microplate format with the QIAamp 96 DNA Qiacube HT kit (Qiagen).
-
bioRxiv - Cancer Biology 2022Quote: ... Exosomal miRNAs were profiled using Human Serum/Plasma miRCURY LNA miRNA PCR array (Qiagen, #YAHS-106Y, Plate Format: 2 × 96-well).
-
bioRxiv - Biochemistry 2020Quote: ... E2 and polyPRM5 proteins were purified using Ni NTA-agarose (Qiagen) followed by cation exchange (Source15S ...
-
bioRxiv - Cell Biology 2019Quote: ... E2 and SUMO were purified using Ni-NTA agarose resin (Qiagen) with 20 mM sodium phosphate pH7.5 ...
-
bioRxiv - Genomics 2020Quote: Total RNA was collected from untreated (T0) and 12h R5020- and E2-treated Ishikawa cells using RNeasy Plus Mini Kit (QIAGEN) and subjected to high-throughput sequencing in Illumina HiSeq 2000 and 2500 ...
-
bioRxiv - Microbiology 2021Quote: ... Assays were run in a 384-well format using the QuantiFast Pathogen RT-PCR + IC Kit (QIAGEN; 211454). USA/WA-1/2020 SARS-CoV-2 RNA (20,000 genome copies per reaction ...
-
bioRxiv - Microbiology 2020Quote: DNA was extracted from the sediment samples using the larger format PowerMax Soil DNA Isolation Kit (12988-10, QIAGEN) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2020Quote: ... DNA extractions were carried out on ground root and shoot tissue and agar pellets using 96-well-format MoBio PowerSoil Kit (MOBIO Laboratories; Qiagen) following the manufacturer’s instruction ...
-
bioRxiv - Bioengineering 2021Quote: Cells were lysed for total protein in 96-well format using the Qproteome Mammalian Protein Prep Kit (Cat. 37901, Qiagen). Protein lysates were loaded onto and analyzed using the WesTM (ProteinSimple ...
-
bioRxiv - Microbiology 2019Quote: DNA extractions were carried out on ground root and shoot tissue and agar pellets using 96-well-format MoBio PowerSoil Kit (MOBIO Laboratories; Qiagen) following the manufacturer’s instruction ...
-
bioRxiv - Microbiology 2021Quote: ... Vero E6 and A549ACE2 cells in 6 well formats were homogenized using QIAShredder tubes and total RNA isolated using the RNEasy kit with DNase treatment (Qiagen). High quality RNA samples that were verified by a Bioanalyzer (Agilent ...
-
bioRxiv - Molecular Biology 2021Quote: Cytokine concentration in the brain of mice was determined using a Multi-Analyte ELISArray kit (Qiagen) following the manufacturer’s protocol ...
-
bioRxiv - Microbiology 2023Quote: ... we utilized the Multi-Analyte ELISArray kits protocol version 1.4 from SABiosciences (Qiagen, Valencia, CA, USA) for common human chemokines and inflammatory human cytokines according to the manufacturer’s instructions ...
-
bioRxiv - Immunology 2021Quote: ... Plates contained 5 µl of TCL lysis buffer (Qiagen) supplemented with 1%β-mercaptoethanol ...
-
bioRxiv - Microbiology 2020Quote: ... in fastq format and analyzed using CLC Genomics Workbench 12 (Qiagen Bioinformatics). Reads were aligned using the RNA-seq Analysis tool to the following reference genomes ...
-
bioRxiv - Microbiology 2021Quote: ... in fastq format and analyzed using CLC Genomics Workbench 20 (Qiagen Bioinformatics). Reads were imported and failed reads were removed using the Illumina Paired Importer tool ...
-
bioRxiv - Microbiology 2021Quote: ... DNA was extracted in 96-well format from 100 μL of sample using the MagAttract PowerMicrobiome DNA/RNA Kit (Qiagen, Hilden, Germany) automated on a Hamilton Microlab STAR robotic platform ...
-
bioRxiv - Genetics 2021Quote: ... 5 mM Multiplex-Kit (Qiagen) and HPLC water to a total volume of 10 μL per sample ...
-
bioRxiv - Microbiology 2022Quote: Twenty-four multi-amplicon libraries were prepared using the QIAseq 16S/ITS Screening Panel kit (Qiagen, Hilden, Germany) as detailed below ...
-
bioRxiv - Immunology 2020Quote: ... ConM-SOSIP.v7 carrying a C-terminal His-tag (diluted to 6.5nM in TBS) was immobilized onto 96-well Ni-NTA ELISA plates (Qiagen) by incubation for 2 hours at room temperature after which the plates were washed 3 times with TBS ...
-
bioRxiv - Genetics 2019Quote: ... in 384 well plates in a total volume of 5 μl with 2.5 μl Qiagen Multiplex PCR Plus Kit (Qiagen, Hilden, Germany) and 1 μl Qiagen Q-solution using a Yakima Yellow-labelled primer ...
-
bioRxiv - Immunology 2020Quote: SARS-CoV-2 ELISA was developed in-house using His tagged proteins bound on Ni-NTA HisSorb Strips or Plates (Qiagen). ELISA assay on mouse sera were performed with His-tagged SARS-CoV-2 full length Spike protein (produced in baculovirus ...
-
bioRxiv - Microbiology 2023Quote: ... The read files in FASTQ format were imported into CLC Genomics Workbench v11 (Qiagen) and trimmed for quality ...
-
bioRxiv - Biochemistry 2020Quote: Cells seeded in 6 well plates were grown in 5% FBS to a confluency of 70% before RNA extraction using the RNEasy mini kit (Qiagen, Hilden, Germany) following the manufacturer’s instructions ...
-
bioRxiv - Physiology 2023Quote: Cytokines secreted from nonapoptotic and apoptotic NCTC cells were screened with the Human Inflammatory Cytokines Multi-Analyte ELISArray Kit (QIAGEN). Nonapoptotic and apoptotic NCTC cell supernatants were prepared in replicate serial dilutions of the Antigen Standard ...
-
bioRxiv - Immunology 2024Quote: ... Ribosomal RNA was depleted from the total RNA using QIAseq fast select multi-RNA removal kit for mouse RNA(Qiagen) and then RNAseq libraries were made using NEB Next Ultra II Directional RNA library prep kit for Illumina ...
-
bioRxiv - Molecular Biology 2020Quote: The sequences in fastq format were analyzed by CLC Genomics Workbench© v 20.0 (Qiagen), using the corresponding C ...
-
bioRxiv - Cancer Biology 2019Quote: Cell lysates were harvested following an 8 hour E2 or DMSO control induction with buffer RLT plus (Qiagen) containing 1% beta-mercaptoethanol (Sigma-Aldrich) ...
-
bioRxiv - Systems Biology 2019Quote: ... The SWIM plates were purified (Qiagen, PCR Purification Kit) and processed to make an Illumina sequencing library ...
-
bioRxiv - Cell Biology 2022Quote: ... single cells were sorted into PCR plates containing 5 µl Buffer RLT Plus (Qiagen) with 1% BME and immediately frozen at -80°C for G&T sequencing.
-
bioRxiv - Cell Biology 2022Quote: ... HMECs at P6 were reverse-transfected with 30 nM miRNA in 384-well format using HiperFect (QIAGEN), in triplicate using Janus apparatus (Perkin Elmer ...
-
bioRxiv - Microbiology 2021Quote: ... or the DNeasy® 96 Blood & Tissue plate kit (Qiagen) according to supplier’s protocol.
-
bioRxiv - Cancer Biology 2022Quote: ... Total RNA was harvested following an 8 hour DMSO or 10 nM E2 induction with buffer RLT plus (Qiagen, 1053393) supplemented with 1% beta-mercaptoethanol (Sigma Aldrich ...
-
bioRxiv - Genomics 2019Quote: ... phagocytosed by sorting cells into a 96 well plate containing 5 ul of RLT (Qiagen) + 1%β-Mercaptoethanol (Sigma).
-
bioRxiv - Immunology 2022Quote: ... single-cells were sorted in 96-well plates containing 5 µL of TCL buffer (Qiagen) with 1% β-mercaptoethanol according to the gating strategy shown in Fig ...
-
bioRxiv - Genomics 2021Quote: ... Raw reads in fastq format that passed filters were used for analysis using CLC Genomics Workbench 12.0 (Qiagen). Detailed information on MiSeq sequencing runs is listed in Supplementary Table 4.
-
bioRxiv - Neuroscience 2023Quote: ... PCR was conducted with the Mouse Inflammasomes (96-well format) RT2 Profiler PCR Array (Cat. # PAMM-097Z, Qiagen) according to the manufacturers protocol and was read on an Applied Biosystems® ViiA 7 Real-Time PCR System and analysis was conducted on QuantstudioTM Software by Applied Biosystems ...
-
bioRxiv - Microbiology 2020Quote: ... 5 μl of Taq PCR Master Mix kit (Qiagen), 0.4 μl of each primer (100 pmol/μl ...
-
bioRxiv - Molecular Biology 2022Quote: ... PCR products were analysed with multi-capillary electrophoresis using QIAxcel (Qiagen; Hilden, Germany). Some of the PCR products performed inadequately in terms of amplification success and PCRs were repeated in 25 μl volumes containing 2 μl ultrapure H2O ...