Labshake search
Citations for Pall :
1 - 21 of 21 citations for Zika Virus Lysate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... virus containing supernatants were clarified using a 0.45 µM PDVF filter (Pall Corp, NY, USA # 4614) and pelleted by ultracentrifugation on a 15% sucrose cushion before resuspension in culture media to achieve a 20X concentration over the original volume ...
-
bioRxiv - Systems Biology 2023Quote: ... Cell lysates were clarified in filter plates (Pall Cat# 8075) at 3500 rpm for 30 minutes ...
-
bioRxiv - Microbiology 2023Quote: Binding of virus and sialic receptor analogous was measured using an Octet Red biolayer interferometer (Pall FortéBio) as previously described (37) ...
-
bioRxiv - Cell Biology 2022Quote: Cleared lysates were syringe filtered (Pall Life Sciences, Product ID 4187) and added to 0.625 mL of glutathione-sepharose beads (GE Healthcare ...
-
bioRxiv - Systems Biology 2019Quote: ... Lysates were spin-filtered through 0.2 um multi-well filters (Pall). After filtration ...
-
bioRxiv - Microbiology 2023Quote: ... and the lysate was filtered through 0.45 µm Supor-450 filters (Pall). Recombinant proteins were immobilized on a HiTrap Talon crude 1 mL column (GE Healthcare) ...
-
bioRxiv - Microbiology 2020Quote: Purified virus binding to different sialylated receptor analogues was tested using an Octet RED bio-layer interferometer (Pall ForteBio) as described previously [21] ...
-
bioRxiv - Microbiology 2021Quote: ... Cell culture supernatant obtained from infected epithelial cells was filtered by Ultipor VF Grade UDV20 Virus Removal Filter Cartridges (PALL) to remove virion ...
-
bioRxiv - Biochemistry 2021Quote: ... The lysate was then filtered using a 0.45 μM Acrodisic syringe filter (Pall) and applied to a 5 mL Ni2+-NTA affinity column (GE Healthcare ...
-
bioRxiv - Cancer Biology 2022Quote: ... and the lysates were deproteinized with a Nanosep Centrifugal Filtration Device (10K) (Pall, OD010C33). The lysates were incubated with a working solution at 37 ºC for 30 min for intracellular metabolites or at room temperature for 30 min for ATP ...
-
bioRxiv - Microbiology 2024Quote: The virus receptor binding avidities were determined by a biolayer interferometry assay with an Octet RED instrument (Pall ForteBio, Menlo Park, CA). Two biotinylated glycan analogs (3’SLN ...
-
bioRxiv - Immunology 2023Quote: ... The lysates were filtered using AcroPrep Filter Plates with Bio-Inert Membranes (Pall Life Sciences), then separated by SDS-PAGE and transferred onto Western Blot membranes ...
-
bioRxiv - Cell Biology 2021Quote: ... Cell lysates (10 μg each) were separated on 7.5% polyacrylamide gels and transferred on to PVDF membranes (Pall). Then the membranes were incubated in Blocking One (Nacalai Tesque ...
-
bioRxiv - Plant Biology 2021Quote: ... Cell lysates were cleared by centrifugation at 13,000 g for 30□min at 4°C and the lysate was filtered through 0.45□ µm Supor-450 filters (Pall). Recombinant proteins were immobilized on a HiTrap Talon crude 1 ml column (GE Healthcare) ...
-
bioRxiv - Bioengineering 2021Quote: ... coli expression strains were lysed in 300µL lysis buffer + 1:50,000 benzonase + 0.6mg/mL lysozyme + 0.1mg/mL polymyxin B and clarified lysates were flowed over 50µL Ni-NTA superflow resin in each well of a 96-well filter plate (Pall) and by centrifugation at 2200g for 10 min ...
-
bioRxiv - Microbiology 2023Quote: ... Cells and cellular debris were removed from the lysate by centrifugation (7000×g, 4 °C, 10 min.) and filtration through a 0.2 μm SUPOR syringe filter (Pall). Lysate titer was determined by serially diluting lysates in mod ...
-
bioRxiv - Cancer Biology 2022Quote: ... Of each depleted serum and whole cell lysate 20 μg protein was concentrated onto a 10 kDa MWCO filter (molecular weight cut-off filter; Pall Nanosep Centrifugal Devices with Omega Membrane ...
-
bioRxiv - Plant Biology 2023Quote: ... 2017) with slight modification: supernatant of cell lysates was loaded onto 96-well glass fiber filter plates (Pall Laboratory 8032). Gene-specific and transposon multiplex primer PCR was performed under standard conditions with 2X GoTaq Green Master Mix (Promega ...
-
bioRxiv - Microbiology 2021Quote: ... the co-immunoprecipitation sample and 2% whole-cell lysates were analyzed by SDS-PAGE and transferred to a polyvinylidene difluoride (PVDF) membrane (Pall Corp.). The membrane was blocked in 3% skim milk in phosphate buffered saline with Tween 20 (PBST ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... The insoluble fraction of the lysate was removed via centrifugation through 1 mm glass fiber Acroprep Advance 96-well filter plates (8031, Pall, USA). The soluble flow-through fraction was analyzed by SDS-PAGE ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... and RNase A treated as described above before the lysate was passed through the filter of an AcroPrep™ PALL2 plate (Cat #: PALL 5053) to bind the gDNA ...