Labshake search
Citations for Pall :
1 - 46 of 46 citations for Streptavidin ZAP Antibody Kit rat since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2019Quote: ... Streptavidin biosensors (Pall ForteBio) were hydrated at 26 °C using the Sidekick shaker accessory for 10 min at 1000 rpm ...
-
bioRxiv - Biochemistry 2022Quote: ... Streptavidin biosensor tips (Pall FortéBio) were pre-equilibrated in Octet buffer (1X DPBS [Gibco] with 0.1 % BSA and 0.05 % Tween-20 ...
-
bioRxiv - Biochemistry 2021Quote: ... Streptavidin (SA)-coated biosensors (Pall FortéBio) were hydrated in HKMTx for at least 30 min at 25 °C prior to use ...
-
bioRxiv - Biochemistry 2020Quote: ... Streptavidin (SA)-coated biosensors (Pall FortéBio) were hydrated in HKTTx solution for at least 10 min prior to use ...
-
bioRxiv - Biochemistry 2019Quote: ... Streptavidin (SA)-coated biosensors (Pall FortéBio) were hydrated in HKMTx for at least 30 min prior to use ...
-
bioRxiv - Biochemistry 2021Quote: ... using Streptavidin (SA)-coated biosensors (Pall FortéBio) in an assay buffer of 100 mM NaCl ...
-
bioRxiv - Synthetic Biology 2019Quote: Streptavidin sensors (Pall, Menlo Park, CA, USA) were pre-equilibrated in PBS buffer for 600s and loaded with biotinylated 209bp_CYC1pro or 209bp_benO_CYC1pro (100 nM ...
-
bioRxiv - Immunology 2021Quote: ... Super Streptavidin biosensors (fortéBio, Pall Life Science) were dipped in PBS prior to use and reacted with 5.8 μg/ml biotinylated peptide-loaded HLA molecule ...
-
bioRxiv - Biochemistry 2020Quote: ... using Streptavidin (SA)-coated biosensors (Pall FortéBio) in 20 mM HEPES pH 7.4 ...
-
bioRxiv - Microbiology 2021Quote: ... Super Streptavidin (SSA) biosensors (Pall ForteBio, CA, USA) were pre-equilibrated in buffer for 10 min at room temperature ...
-
bioRxiv - Immunology 2019Quote: ... Streptavidin-coated biosensor tips (Pall ForteBio, Menlo Park, CA) were used to capture biotinylated antigens ...
-
bioRxiv - Microbiology 2020Quote: ... Sialoglycopolyemers were bound onto streptavidin coated biosensors (Pall ForteBio) at ranges of concentrations from 0.01-0.55μg/ml in 10mM HEPES ...
-
bioRxiv - Microbiology 2023Quote: ... Sialylglycopolymers were immobilized on streptavidin-coated biosensors (Pall FortéBio) at concentrations ranging from 0.01 to 0.5 µg/ml in a solution containing 10 mM HEPES (pH 7.4) ...
-
bioRxiv - Immunology 2020Quote: ... was immobilized onto SAX biosensors (high precision streptavidin sensors: Pall fortebio ...
-
bioRxiv - Microbiology 2022Quote: ... equipped with High Precision Streptavidin (SAX) biosensors (PALL Life sciences, USA). Proteins were biotinylated using NHS-PEG4-Biotin (Thermo Scientific ...
-
bioRxiv - Immunology 2022Quote: Biotinylated peptides (100 nM) were loaded on streptavidin biosensors (Pall ForteBio) to a load threshold of 0.1 nm ...
-
bioRxiv - Immunology 2021Quote: ... (1) Biotinylated ACE2 (300 nM) was loaded on Streptavidin biosensors (Pall ForteBio) to a load threshold of 0.4-0.6 nm ...
-
bioRxiv - Microbiology 2020Quote: ... Biotinylated-rsCSP were loaded onto streptavidin biosensors (Pall ForteBio, cat No 18-5019) at 10 μg/mL in kinetics buffer (TBS + 0.002 % Tween20 and 0.01 % BSA) ...
-
bioRxiv - Microbiology 2022Quote: Biotinylated MPER peptide (30 nM) was loaded onto a streptavidin biosensor (Pall Fortebio) to a load threshold of 0.6 nm using an Octet RED96 system (Pall ForteBio) ...
-
bioRxiv - Biophysics 2023Quote: ... BLI sensors coated with streptavidin (SA sensors) were purchased from Forte Bio (PALL). Prior to use ...
-
bioRxiv - Biochemistry 2021Quote: ... For binding analysis biotinylated antigen (1 μg/mL) were immobilized on streptavidin (SA) biosensors (Pall) for 300 sec to ensure saturation ...
-
bioRxiv - Molecular Biology 2020Quote: ... biotinylated SARS-CoV-2 S trimer protein was loaded onto streptavidin (SA) biosensors (Pall FortéBio). S-trimer-bound biosensors were dipped into wells containing varying concentrations of ACE2 protein and the interactions were monitored over a 500-sec association period ...
-
bioRxiv - Microbiology 2023Quote: ... Biotinylated VHH16 (4 μg/mL) were loaded on streptavidin SA (18–0009) biosensors (Pall ForteBio) for 1 min ...
-
bioRxiv - Bioengineering 2020Quote: Biolayer inferometry was performed using the Octet Red96 with streptavidin (SA) biosensors (Pall ForteBio, Fremont, CA), which were hydrated for 15 min in kinetics buffer prior to each run ...
-
bioRxiv - Biophysics 2022Quote: ... Biotinylated PAR was captured on High precision Streptavidin (SAX) Dip and Read™ biosensors (Pall Fortebio) with a threshold of 0.4-0.5 nm ...
-
bioRxiv - Cell Biology 2024Quote: ... using ATF6⍺_LD variants as biotinylated ligands that were immobilised on streptavidin (SA)-coated biosensors (Pall FortéBio) and rat calreticulin (rCRT ...
-
bioRxiv - Biochemistry 2019Quote: ... 10 ng/mL of biotin-labeled target were loaded on Dip and Read™ Streptavidin (SA) Biosensors (Pall Fortebio) until the reading exceeded 1 nm ...
-
bioRxiv - Microbiology 2022Quote: ... Biotinylated SARS-CoV-2 RBD or S1 (4 µg/mL) were loaded on streptavidin SA (18-0009) biosensors (Pall ForteBio) for 1 min ...
-
bioRxiv - Cancer Biology 2020Quote: ... pH 7.4 and loaded onto Octet Streptavidin (SA) Biosensors (ForteBio) by following the manufacturer’s recommendations on an Octet RED384 machine (ForteBio, PALL Octet System). Biotin-249C immobilization was checked via Octet® Software prior to introduction of the entire V-ATpase complex and the individual H subunit protein diluted in blocking buffer (1X PBS + 0.05% Tween 20 + 0.2 % BSA + 10 μM Biotin ...
-
bioRxiv - Bioengineering 2020Quote: ... Affinity measurements were carried out at room temperature using an Octet RED96 system and streptavidin (SA)-coated biosensor tips (Pall ForteBio). Biotinylated ACE2 variants were diluted to 10 nM in PBS with 0.2% BSA and 0.05% Tween-20 (PBS-T) ...
-
bioRxiv - Microbiology 2024Quote: ... The glycans were preloaded onto streptavidin-coated biosensors at up to 0.3 µg/ml for 5 minutes in 1 × kinetic buffer (Pall FortéBio, Menlo Park, CA). Each test virus was diluted to a final concentration of 100 pM with 1 × kinetic buffer containing 10 µM oseltamivir carboxylate (American Radiolabeled Chemicals ...
-
bioRxiv - Bioengineering 2019Quote: ... the anti-CHO HCP Detection Kit (Pall) was used according to the manufacturer’s specifications ...
-
bioRxiv - Immunology 2020Quote: KD determination of full-length antibodies: Protein A biosensors (Pall ForteBio) were used to immobilize recombinant antibodies at 2.7 μg/ml for 1min ...
-
bioRxiv - Immunology 2020Quote: The binding sites of obtained antibodies to RBD was examined by Blitz system (ForteBio, Pall Lifesciences). 10 μg/ml Biotinylated RBD protein was captured by streptavidin biosensor (ForteBio ...
-
bioRxiv - Microbiology 2023Quote: ... Two kit controls (Qiagen glass filter and PALL; Lucigen glass filter and PALL) were also sequenced to reveal contaminants ...
-
bioRxiv - Microbiology 2023Quote: ... Two kit controls (Qiagen glass filter and PALL; Lucigen glass filter and PALL) were also sequenced to reveal contaminants ...
-
bioRxiv - Immunology 2021Quote: ... Antibodies were concentrated and re-suspended in PBS using 30 kDa cutoff Macrosep Advanced Centrifugal Devices (Pall Corporation). To purify monoclonal antibodies ...
-
bioRxiv - Bioengineering 2021Quote: ... Peptides were isolated from antibody and MHC molecules using a passivated 10K molecule weight cutoff filters (PALL Life Science), lyophilized ...
-
bioRxiv - Cancer Biology 2022Quote: ... Peptides were isolated from antibody and MHC molecules using a passivated 10K molecule weight cutoff filter (PALL Life Science), lyophilized ...
-
bioRxiv - Developmental Biology 2021Quote: ... Antibodies were tested for binding to the ACVR1 ECD by biolayer interferometry using an Octet HTX instrument (Pall/Forte Bio). Confirmed binders were evaluated for the ability to block BMP-mediated ACVR1 signaling in a cell-based reporter assay described below.
-
bioRxiv - Microbiology 2021Quote: The kinetics of GPΔmuc and GPΔmuc-presenting NP binding to a panel of 10 antibodies was measured using an Octet RED96 instrument (FortéBio, Pall Life Sciences). All assays were performed with agitation set to 1000 rpm in FortéBio 1× kinetic buffer ...
-
bioRxiv - Microbiology 2021Quote: ... binding to a panel of known antibodies (in the IgG form) was measured using an Octet RED96 instrument (FortéBio, Pall Life Sciences). All assays were performed with agitation set to 1000 rpm in FortéBio 1× kinetic buffer ...
-
bioRxiv - Microbiology 2019Quote: The kinetics of E2 cores and nanoparticle binding to HCV-specific antibodies was measured using an Octet Red96 instrument (fortéBio, Pall Life Sciences). All assays were performed with agitation set to 1000 rpm in fortéBio 1× kinetic buffer ...
-
bioRxiv - Genetics 2022Quote: ... In vivo biotinylated iMab-MycAviTag antibody fragments were purified by affinity chromatography and biotinylation confirmed by biolayer interferometry using a BLItz system (Pall ForteBio LLC) and streptavidin sensors.
-
bioRxiv - Immunology 2022Quote: ... Umbilical cord blood was collected at the time of delivery using umbilical cord blood collection kits (Pall Medical) and an aliquot of whole cord blood was preserved in RNAlater (ThermoFisher) ...
-
bioRxiv - Molecular Biology 2020Quote: The micro bicinchoninic acid (BCA) protein assay kit and Nanosep® 30K Omega Centrifugal Devices were purchased from Pall Life Sciences (Ann Arbor MI ...