Labshake search
Citations for Olympus :
1 - 50 of 201 citations for Dl 4 Methoxyestradiol 13 14 15 16 17 18 13C6 99% since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2023Quote: Young gravid adult hermaphrodites were kept at 13-14°C in a small incubator (Wine Enthusiast, model 2720213W) dissected on a high-resolution dissecting microscope (Olympus SZX16 with an Olympus SDF PLAPO 1XPF objective ...
-
bioRxiv - Immunology 2024Quote: ... The nuclei were stained with DAPI for 15 minutes before being imaged with a laser scanning confocal microscope[18] (FV300; Olympus).
-
bioRxiv - Neuroscience 2019Quote: ... Beam was passed through an air objective (4 x, 0.16 NA, UPlanApo, Olympus, beam diameter ~8-16 μm). Timing and light power of the laser stimulation was controlled by a TTL-controlled shutter (Uniblitz ...
-
bioRxiv - Neuroscience 2022Quote: DLS brain slices were visualized on a BX51WI microscope (Olympus Corporation of America, USA). Whole-cell patch clamp electrophysiological recordings were made from medium spiny neurons (MSNs ...
-
bioRxiv - Neuroscience 2021Quote: ... Images were acquired at 15 Hz using a 4×4 binning to yield 640×540 pixel images through a 4x air objective (Olympus, UPlanFL N 4x/0.13 NA).
-
bioRxiv - Genetics 2022Quote: ... equipped stereo-microscope (Olympus SZX-16) for 60 seconds with the relative volume (V/V0 ...
-
bioRxiv - Cell Biology 2021Quote: ... 18 and 27 using cellSens imaging software (Olympus, USA) (Fig 1C).
-
bioRxiv - Neuroscience 2020Quote: ... EM CCD camera (Hamamatsu 9100-13) and imaging software (Olympus Excellence Pro) was applied for image acquisition ...
-
bioRxiv - Neuroscience 2022Quote: ... We identified the DLS under bright field illumination using an upright fixed-stage microscope (BX51 WI; Olympus, Center Valley, PA). Stimulating and recording electrodes were both placed in the DLS ∼100 µm away from each other ...
-
bioRxiv - Cell Biology 2019Quote: ... colonies were imaged using SZX-16 stereo microscope (Olympus) wherein the light source was above the colony ...
-
bioRxiv - Bioengineering 2024Quote: A 500-kHz single-element spherical-focused transducer (18-0018-P, Olympus) was employed for all trials ...
-
bioRxiv - Neuroscience 2024Quote: Neurons were recorded at DIV13-17 at RT on an IX73 inverted microscope (Olympus) using a Multiclamp 700B amplifier under the control of a Digidata 1550 AD board and Clampex 10 software (all Molecular Devices) ...
-
bioRxiv - Microbiology 2021Quote: ... Images were visualized and adjusted to 14 bit in LCmicro_2.2 software (Olympus).
-
bioRxiv - Neuroscience 2020Quote: ... selected by GFP or mCherry expression under fluorescent stereomicroscope (Olympus SZX 16), was performed ...
-
bioRxiv - Neuroscience 2019Quote: ... A CCD camera is coupled to the microscope and used at the start of the experiment to place the electrodes over the region of interest using a 4X objective (UPLFLN 4X, NA 0.13, W.D 17 mm, Olympus). Subsequently a 40X water immersion objective with a long working distance (LUMPLFLN 40XW ...
-
bioRxiv - Cell Biology 2024Quote: ... Time-lapse videos were acquired for 15 min at 15 s intervals using a 10× dry objective lens (NA 0.3, Olympus, Tokyo, Japan) on a deconvolution microscope (CellTIRF) ...
-
bioRxiv - Synthetic Biology 2023Quote: ... was acquired by 17-20 Hz at a 256 × 256 pixel resolution using a 40X water-immersion objective (LUMPlanFL, NA 0.8, Olympus) and the 920 nm laser wavelength ...
-
bioRxiv - Neuroscience 2023Quote: ... Larvae were screened at 5 dpf at an epifluorescence dissection microscope (Olympus SZX-16) and those showing mosaic labelling of Purkinje neurons were selected for experiments ...
-
bioRxiv - Developmental Biology 2023Quote: Six-well flat bottom culture plates (Olympus Plastics Cat# 25-100, 16 ml capacity) were used for all fertilization tests ...
-
bioRxiv - Neuroscience 2024Quote: ... Images of 16-bits were acquired using the camera software Olympus cellSensTM (Olympus Corporation) at 500 ms exposure/frame for 5-6 min ...
-
bioRxiv - Biochemistry 2023Quote: ... equipped with an electron-multiplying CCD camera (Hamamatsu Photonics, ImagEM C9100-13) and 150x objective lens (UAPON 150x OTIRF, NA/1.45; Olympus). mNeonGreen and mCherry were excited using 488 nm and 561 nm lasers ...
-
bioRxiv - Bioengineering 2023Quote: Ultrasound pulses were emitted from an immersion transducer (A303 S-SU, diameter: 13 mm, focal distance: 15.2 mm, center frequency: 1 MHz; Olympus), driven by a function generator (33500 B Series ...
-
bioRxiv - Developmental Biology 2021Quote: ... Chamber slides containing attached explants were imaged at 3 minutes and 27 second intervals for 17 hours using an FV1200 laser scanning microscope (Olympus) with a stage top incubator (Tokai Hit) ...
-
bioRxiv - Neuroscience 2019Quote: ... Italy) specialized for loading 18 mm round coverslips and mounted on an inverted motorized microscope (Olympus IX83, Olympus) equipped with a 100X1.49NA PL-APO objective and an azimuthal drift control device ...
-
bioRxiv - Biophysics 2019Quote: ... The emitted fluorescence was imaged with a spinning disk (Olympus IX2-DSU, spinning disk strip gap 18 μm) on the CMOS camera.
-
bioRxiv - Neuroscience 2019Quote: ... Italy) specialized for loading 18 mm round coverslips and mounted on an inverted motorized microscope (Olympus IX83, Olympus) equipped with a 100X1.49NA PL-APO objective and an azimuthal drift control device ...
-
bioRxiv - Microbiology 2021Quote: ... The micropipettes were then cut with a sharp scalpel under a stereomicroscope (Olympus SZX-16) to generate a wider tip ...
-
bioRxiv - Cell Biology 2022Quote: ... for 15 minutes and visualized by epifluorescent microscopy (Olympus BX61).
-
bioRxiv - Plant Biology 2022Quote: Lateral root numbers in whole roots of 13-day-old seedlings were counted using an Olympus SZX7 microscope (Olympus, Tokyo, Japan). Stage classification was determined according to Malamy and Benfey (1997) ...
-
bioRxiv - Cell Biology 2019Quote: ... Bright-field imaging of 7-day old colonies were done using SZX-16 stereo microscope (Olympus) wherein the light source was below the colony ...
-
bioRxiv - Cell Biology 2019Quote: ... Samples were imaged with 1x objective (LaVsion 0.1 NA [WD= 17 mm] or 4x objective (Olympus XLFLUOR 0.28 NA [WD = 10 mm]), and 12x objective (LaVsion 0.53 NA [WD= 10 mm]) ...
-
bioRxiv - Cell Biology 2022Quote: ... and imaged every 10 minutes for 18 hours using a humidity- and temperature-controlled inverted wide-field microscope within an environmental chamber (ScanR, Olympus). Nuclear tracking and cell motility analysis were performed as described here (24) ...
-
bioRxiv - Biophysics 2023Quote: ... slide SIM images were acquired on a custom Structured Illumination Microscope [18] using a 100x 1.3 NA oil immersion (Olympus, UPlanFluor) objective and 465 nm excitation light derived from a diode laser (Lasever ...
-
bioRxiv - Biophysics 2024Quote: ... and a U-DFA 18 mm internal diameter dark-field annulus with a UPlanAPO 10× magnification objective (NA= 0.4, Olympus, Japan). The sperm flagellar centreline was extracted using an automated image analysis algorithm as detailed in Nandagiri et al.26
-
bioRxiv - Biochemistry 2023Quote: ... equipped with a 4-line TIRF condenser (Olympus TIRF 4-Line LCl), a CMOS camera (ORCA-Flash 4.0 ...
-
bioRxiv - Physiology 2024Quote: ... ×4 (PlanN, 0.10NA, Olympus), ×20 (UMPlanFL N ...
-
bioRxiv - Cancer Biology 2020Quote: ... The number of formed organoids that reached 100 μM of diameter was counted on days 14 post plating with cellSens software (Olympus). For the Dose-Response experiment 1×104 mouse prostate cells were plated in 40μl of Matrigel and treated with vehicle (0.1% DMSO ...
-
bioRxiv - Microbiology 2019Quote: ... day 5 (both before and after washing) and on day 14 of experiments and were analysed using Cell^F software (Olympus). To visualize activity of the amoeba ...
-
bioRxiv - Immunology 2021Quote: ... Sections were permeabilized for 8 or 14 min and imaged using the Metafer Slide Scanning Platform (Metasystems) or the IX73 Inverted Microscope Platform (Olympus). Raw images were processed using VSlide software (Metasystems) ...
-
bioRxiv - Neuroscience 2020Quote: Live-cell fluorescent Ca2+ imaging in cultured hippocampal neurons (DIV 10-14) was performed on a dual scanner Olympus Fluoview 1200 with a 20× objective (Olympus) at 37 °C in 5% CO2 ...
-
bioRxiv - Cell Biology 2023Quote: ... The number of organoids was manually counted and organoid diameter was measured at day 14 of the culture using an Olympus IX50 light microscope connected to Cell^A software (Olympus).
-
bioRxiv - Cell Biology 2022Quote: ... 16 fields of view were imaged using a 20X magnification objective with a 0.75-NA (Olympus; uplsapo20x) on 8 different z-slices with an inter-z-slice interval of 4 μm ...
-
bioRxiv - Genomics 2023Quote: ... Cell images were taken at multiple time points (0, 8, 16, 24, and 33 hours) by Olympus IX71 microscope ...
-
bioRxiv - Neuroscience 2021Quote: ... chicken embryos were electroporated at HH17-18 and neural tubes were dissected 24 hours later under a fluorescence microscope (Olympus SZX12). Total RNA was then reverse transcribed using SuperScript(tm ...
-
bioRxiv - Plant Biology 2019Quote: ... or subjected to heat stress for 5-9 or 10-14 days as described above using a stereoscopic light microscope (SZX12, Olympus、Japan) and a scanning electron microscope (SEM ...
-
bioRxiv - Neuroscience 2019Quote: Chronic in vivo imaging of the layer 1 OLs and myelin segments was initiated 14-21 days after the implantation of the cranial window and was performed using an Olympus FV-RS microscope (Olympus, Japan) equipped with a femto-second pulsed Ti:Sapphire laser (Mai Tai HP-DS ...
-
bioRxiv - Microbiology 2019Quote: ... From day 16-26 post infection salivary glands of infected mosquitos (sorted by fluorescence stereomicroscope Olympus SZX10/ U-HGLGPS) were dissected into serum free IMDM (Iscove’s Modified Dulbecco’s Medium ...
-
bioRxiv - Neuroscience 2023Quote: ... The motor cortex was imaged at a depth of 100-200 μm below the pial surface using Prairie View 5.5.64.100 software with an Ultima Investigator 2-photon microscope (Bruker) equipped with a 16×/0.80 NA water-immersion objective (Olympus) and an InSight X3 tunable laser (Spectra-Physics) ...
-
bioRxiv - Neuroscience 2021Quote: ... A 4×0.13 NA objective (Olympus) was focused 200 microns below the cortical surface ...
-
bioRxiv - Neuroscience 2022Quote: ... NY) and a 4× objective (Olympus) using a cooled CCD camera (Rolera ...