Labshake search
Citations for Sutter Instruments :
1 - 50 of 217 citations for 7 8 Dihydro 6H 1 6naphthyridin 5 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... pulled to 7-8 MΩ using a horizontal puller P-97 (Sutter Instrument, US) and fire polished to 9-12 MΩ ...
-
CDK5 activity in retinal pigment epithelium contributes to gap junction dynamics during phagocytosisbioRxiv - Cell Biology 2023Quote: ... Patch pipettes (5–7 MΩ, BF120-69-10, Sutter Instruments) were filled with an intracellular solution composed of (in mM) ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch pipettes (5-8 MΩ) were pulled (P-87 puller, Sutter Instruments) from borosilicate glass capillaries (Science Products ...
-
bioRxiv - Neuroscience 2021Quote: ... Electrophysiology recordings were made using SutterPatch 7/8 software utilizing Sutter Integrated Patch Clamp Amplifier and Data Acquisition System (Sutter Instruments). Pipette solution contained (in mM) ...
-
bioRxiv - Cell Biology 2021Quote: ... were pulled to resistances of 5 - 8 MΩ (P-2000; Sutter Instruments, Novato CA). The standard pipette solution contained (in mM) ...
-
bioRxiv - Molecular Biology 2024Quote: ... with a Flaming-Brown P-97 puller (Sutter Instruments; tip resistance 5–8 MΩ). The pipette solution contained (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... were pulled to tip resistances of 5-8 M Ώ using a multi-stage puller (Sutter Instruments) and were filled with K-gluconate based intracellular solution ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch electrodes were pulled to tip resistances of 5-8 MΩ using a multistage puller (Sutter Instruments) and were filled with intracellular solution ...
-
bioRxiv - Developmental Biology 2023Quote: ... one from Sutter Instrument. Various tubing is necessary for fluid handling ...
-
bioRxiv - Neuroscience 2023Quote: ... in the supra-pyramidal blade of the dentate gyrus was recorded with a borosilicate glass pipette taper-pulled to an impedance of 5-7 MOhm (Sutter Instruments) and filled with the ACSF solution ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate pipettes of 5 – 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter instruments). All recordings were done in current clamp with an intracellular solution containing 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2019Quote: ... Pipettes (5-7 MΩ) were pulled from borosilicate glass tubing (outer diameter 1.5 mm, inner diameter 0.86 mm; Sutter Instruments, Novato, CA, USA) and filled with a solution containing (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... World Precision) to obtain pipette resistance ranging from 5 – 8 MΩ using next generation micropipette puller (P-1000, Sutter Instrument). External solution is consist of 140 mM NaCl ...
-
bioRxiv - Neuroscience 2023Quote: Patch pipette of 5-8 MΩ tip resistance were fabricated from borosilicate glass by using a microelectrode puller (Sutter Instruments). The initial access resistance was 18.2±0.5 MΩ for current-clamp recordings (n=21 ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch electrodes (5-7 MΩ) were pulled from borosilicate glass capillaries using a Flaming/Brown P-97 micropipette puller (Sutter Instrument, Novato, CA). Pipette internal solution contained (in mM ...
-
bioRxiv - Physiology 2019Quote: ... were pulled to low tip resistance (5-7 MΩ) using a Flaming-Brown PC-84 micro-pipette puller (Sutter Instruments, Novato, CA, USA) and back-filled with 500 mM KCl solution ...
-
bioRxiv - Physiology 2020Quote: ... glass microelectrodes were pulled to a tip resistance of 5-7 MΩ on a Flaming-Brown P-1000 Micropipette puller (Sutter Instruments, Novato, CA, USA). TPP was measured with a Duo 773 intracellular/extracellular amplifier (World Precision Instruments ...
-
bioRxiv - Physiology 2023Quote: ... pulled to form low resistance tips (approximately 5–7 MΩ) using a model P-87 Flaming/Brown micropipette puller (Sutter Instruments, Novato, CA, USA). These microelectrodes were backfilled with 500 mM KCl ...
-
bioRxiv - Molecular Biology 2023Quote: ... 20 cm length) with a 5 to 8 μm tip opening generated using a laser puller (Sutter Instrument Co, model P-2000). Samples were loaded onto the LC using an autosampler at 800 nl/min and eluted at 400 nl/min over a 90-minute gradient with solvent composition rising from 2% to 35% acetonitrile with 0.1% formic acid ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes (5-8 MΩ) were stretched from borosilicate glass capillaries (G150TF-3, Warner instruments) using a pipette puller (Sutter Instruments, P-87, Novato, CA) and filled with a few microliters of an intracellular solution adjusted to pH 7.2 ...
-
bioRxiv - Biochemistry 2022Quote: ... Nano-spray emitters were generated from fused silica capillary tubing (100 µm internal diameter, 365 µm outer diameter, 5-8 µm tip opening) using a laser puller (Sutter Instrument Co., model P-2000), with parameters set as follows ...
-
bioRxiv - Cell Biology 2024Quote: ... and a 7-channel Lambda 821 (Sutter Instruments, Novato, CA) LED epifluorescence light source with excitation filters on the LEDs ...
-
bioRxiv - Neuroscience 2021Quote: ... using pulled borosilicate glass pipettes (4-7 MΩ resistance, Sutter Instrument) filled with an internal solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (4-7 MΩ) were created from borosilicate glass capillaries (Sutter Instrument) using a P-97 puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipette (4-7 MOhm) were pulled from borosilicate glass filaments (Sutter Instruments) and filled with K-gluconate solution (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (4-7 MΩ) were pulled from borosilicate glass filaments (Sutter Instruments) and filled with a Cesium (Cs2+)-based internal solution (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipette (4-7 MOhm) were pulled from borosilicate glass filaments (Sutter Instrument Co.) and filled with potassium (K)-gluconate solution (GCamp7s characterization ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes (4 – 7 MΩ) pulled from borosilicate glass (Sutter instrument, BF150-86-10) were filled with a K-gluconate based internal solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... pulled to 6-7 MΩ using a horizontal puller P-1000 (Sutter Instruments, US) and fire polished to 9-12 MΩ ...
-
bioRxiv - Neuroscience 2020Quote: ... with 4-7 MΩ borosilicate pipettes (2.0 mm OD, 1.16 mm ID, Sutter Instruments) filled with a standard low-chloride internal solution (120 mM potassium gluconate ...
-
bioRxiv - Neuroscience 2020Quote: Patch-pipettes (3-7 MOhm in bath) were pulled (P87 puller, Sutter Instruments, USA) from borosilicate glass capillaries (GB150F-8P and GB150-8P Science Products ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (4-7 MOhm) were pulled from borosilicate glass filaments (Sutter Instrument Co.) and filled with Cesium (Cs2+)-based internal solution (in mM ...
-
bioRxiv - Bioengineering 2024Quote: ... Recording pipettes (6–7 MΩ) were pulled with a micropipette puller (P1000, Sutter Instrument). For whole-cell recordings ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass micropipettes were fabricated from borosilicate glass capillaries (8-9 MΩ; Sutter Instruments) with the use of a horizontal puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch micropipettes (7-9 MΏ) were pulled from borosilicate glass capillaries (Sutter Instrument, Novato, CA, USA.) using the Sutter Instrument P97 puller ...
-
bioRxiv - Neuroscience 2020Quote: ... One-photon excitation was provided by either a xenon arc lamp (Lambda LS, Sutter Instrument) coupled via a liquid light guide to the epifluorescence port of a Movable Objective Microscope (Sutter Instrument ...
-
bioRxiv - Immunology 2023Quote: ... The fluorescence lamp of setup #2 was equipped with one filter wheel (Sutter Instrument Company) with the following filters installed ...
-
bioRxiv - Neuroscience 2021Quote: ... for patch clamp recordings (4–7 MΩ) were pulled using a micropipette puller (P1000, Sutter Instruments, Novato, CA). Pipette capacitance was compensated for before the formation of the whole-cell configuration ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4-7 MΩ) were pulled from borosilicate glass capillaries on P-97 puller (Sutter Instruments, USA). The series resistance was 10-20 MΩ ...
-
bioRxiv - Neuroscience 2020Quote: ... 8-12 MΩ thick-walled borosilicate electrodes (BF150-86-10HP, Sutter Instrument Company, Novato, CA) were pulled with a P-97 Brown/Flaming Puller (Sutter Instrument Company ...
-
bioRxiv - Neuroscience 2023Quote: ... The pipette (6-8 MΩ) was pulled by a micropipette puller (P-1000, Sutter instrument) and filled with the internal solution that contained (in mM) ...
-
bioRxiv - Cell Biology 2020Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). Electrophysiological recordings from neurons were obtained in Tyrode’s medium ([mM] 150 NaCl ...
-
bioRxiv - Neuroscience 2022Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). Pipettes were filled using standard intracellular solution (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). For hippocampal neuron cultures ...
-
bioRxiv - Neuroscience 2023Quote: ... we pulled borosilicate patch pipettes (2–7 MΩ) using a P-1000 puller (Sutter Instruments, Novato, CA, United States) and filled pipettes with an internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (6–7 MΩ tip resistance, borosilicate glass, outer diameter 1.5 mm, inner diameter 0.86 mm, Sutter Instruments) were filled with the following internal solution (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass (3-7 MΩ resistance) recording pipettes were pulled using a P-1000 Flaming/ Brown micropipette puller (Sutter Instruments). Recordings were performed using an Axopatch 200B amplifier (Molecular Devices) ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... Patch pipettes (4-7 MΩ) were pulled from thin wall borosilicate glass using a micropipette puller (P-97, Sutter Instruments) and filled with a K-Gluconate based intra-pipette solution containing ...
-
bioRxiv - Genomics 2024Quote: ... Microinjection needles were pulled to have a final specification of ∼1.5-μm tip size and ∼7-mm taper length on a P-1000 needle puller (Sutter Instrument), using the following pulling parameters ...
-
bioRxiv - Neuroscience 2024Quote: ... Boroscillate pipettes (Sutter Instruments, 3-5 MΩ) were used for all recordings and whole-cell electrophysiology recordings were performed using a Multiclamp 700B amplifier (Molecular devices) ...