Labshake search
Citations for NanoTemper :
1 - 50 of 175 citations for Hemoglobin High Sensitivity Colorimetric Detection Kit 10 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2023Quote: ... then Plex nanoDSF Grade High Sensitivity Capillaries (NanoTemper) were filled with 10-µl protein sample ...
-
bioRxiv - Biochemistry 2020Quote: ... Approximately 10 μL of each diluted sample was loaded into nanoDSF grade high-sensitivity capillaries (NanoTemper) in triplicate and placed on the instrument’s capillary loading tray ...
-
bioRxiv - Biophysics 2022Quote: ... or nanoDSF Grade High Sensitivity Capillaries (NanoTemper Technologies GmbH), for CNDP52 and ZF2 ...
-
bioRxiv - Cell Biology 2021Quote: ... Samples were loaded in high-sensitivity capillaries (Nanotemper, Munich, Germany) and heated with a 0.5°C/min temperature ramp from 20°C to 70°C.
-
bioRxiv - Molecular Biology 2020Quote: ... 10-µL of undiluted rAAV of each lot was loaded into a high sensitivity capillary (Nanotemper Cat#PR-C006) and run on a Nanotemper Prometheus NT.48 nanoDSF instrument ...
-
bioRxiv - Biophysics 2022Quote: ... LLPS) were prepared in 1.5 ml Eppendorf tubes and loaded into 10 μl high sensitivity microcapillaries (NanoTemper Technologies, Germany) and subjected to DLS measurements ...
-
bioRxiv - Molecular Biology 2023Quote: ... a volume of 10 μl was then placed in Prometheus Series High Sensitivity Capillaries (NanoTemper, Cat. no. PR-C006).
-
bioRxiv - Biochemistry 2023Quote: ... Approximately 10 µL of each sample was loaded into Prometheus NT.48 Series nanoDSF high sensitivity capillaries (NanoTemper, Germany) and melting scans were performed using the Pr.ThermControl software (NanoTemper ...
-
bioRxiv - Molecular Biology 2023Quote: ... pH6) in a volume of 10 μl and placed in Prometheus Series High Sensitivity Capillaries (NanoTemper, Cat. no. PR-C006).
-
bioRxiv - Biophysics 2020Quote: Thermal unfolding of BG505-SOSIP was determined with a heating ramp of 1°C/min and 20% sensitivity setting using high-sensitivity capillaries (NanoTemper Technologies ...
-
bioRxiv - Biochemistry 2022Quote: ... 13000 rpm), filled into Prometheus high-sensitivity capillaries (10 μL each, n=3) and transferred to a Prometheus Panta instrument (NanoTemper Technologies). DLS analysis of BbHtrA S/A rh and PDI were determined using Prometheus Panta’s size analysis function.
-
bioRxiv - Biochemistry 2021Quote: ... Samples of 15 μL were placed in high sensitivity quarts capillaries (Nanotemper) and the temperature was ramped with 1 °C/min from 20 °C to 95 °C ...
-
bioRxiv - Biochemistry 2021Quote: Thermal unfolding was performed in nanoDSF grade high-sensitivity glass capillaries (NanoTemper, Germany) at a heating rate of 1°C per minute ...
-
bioRxiv - Biophysics 2022Quote: Measurements were carried out using a high sensitivity and high throughput capillary based DLS instrument—Prometheus PANTA (NanoTemper Technologies, Germany). α-Syn solutions (monomer ...
-
bioRxiv - Molecular Biology 2021Quote: ... Each sample was loaded into three capillaries of High Sensitivity grade (NanoTemper, cat # PR-C006) and the emission of intrinsic tryptophan fluorescence at 350 nm was monitored.
-
bioRxiv - Biochemistry 2021Quote: Prometheus nanoDSF measurements were performed in duplicate by loading NTF2 samples at absorbance values of 0.2 into high-sensitivity capillaries following the manufacturer’s protocols (Nanotemper). Peptide ligands were dissolved in DMSO and added to NTF2 to yield final DMSO concentrations of 4% (V/V) ...
-
bioRxiv - Cell Biology 2021Quote: ... Samples in the presence and absence of 2 mM ATP with 2 mM MgCl2 were loaded in high-sensitivity capillaries (Nanotemper, Munich, Germany) and heated with a 0.3°C/min temperature ramp from 20°C to 70°C with a 2 sec DLS integration time.
-
bioRxiv - Microbiology 2023Quote: ... and placed in nano-DSF grade Prometheus high-sensitivity capillaries and nano-DSF measurements were carried out using a Prometheus NT.48 (Nanotemper technologies GmbH, Munchen, Germany) with a temperature ramp of 1 °C min−1 ...
-
bioRxiv - Biochemistry 2022Quote: ... Samples were loaded by capillary action into standard sensitivity capillaries and placed within a Prometheus Panta (Nanotemper). The instrument was allowed to stabilize at 20°C before measuring ...
-
bioRxiv - Molecular Biology 2022Quote: ... 10 μM PfCoSP was labeled using NanoTemper’s Protein Labeling Kit RED-NHS (L001, NanoTemper technologies, Germany). The concentration of labeled PfCoSP protein was kept constant at a concentration of 90 nM ...
-
bioRxiv - Synthetic Biology 2022Quote: ... The mixed samples were loaded into a high-quality capillaries (NanoTemper Technologies) and measured at room temperature by using 20% LED power and medium MST power ...
-
bioRxiv - Biophysics 2020Quote: The thermophoretic measurements were performed using Monolith NT.115 device with red detection channel (NanoTemper Technologies, Munich, Germany). Recombinant Spikeplug was produced in our laboratory ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Experiments were run at 20% excitation and high MST power at 23.0°C on a Monolith NT.115Pico (NanoTemper). Each experimental compound was run in triplicate.
-
bioRxiv - Biochemistry 2021Quote: ... Ammonium sulfate suspension of the MDH was centrifuged at 23,000 × g for 1 min at 4 °C and the precipitate was resuspended in the labeling buffer to gain 90 μL of 10 μM MDH and mixed with 10 μL of 300 μM of dye (NanoTemper Technologies) prepared in dimethyl sulfoxide to create 100 μl of dye-protein solution ...
-
bioRxiv - Biochemistry 2024Quote: ... Fluorescence was determined in a thermal gradient at 40% LED power and high MST power generated by a Monolith NT.115 from NanoTemper Technologies ...
-
bioRxiv - Biophysics 2022Quote: ... 10 μL samples were loaded in capillaries (TY-C001, Nanotemper). The intrinsic protein fluorescence was measured at 350 nm and 330 nm ...
-
bioRxiv - Biophysics 2021Quote: ... 10 μL samples were loaded in capillaries (TY-C001, Nanotemper). The intrinsic protein fluorescence was measured at 350 nm and 330 nm ...
-
bioRxiv - Cell Biology 2022Quote: ... employing the Monolith His-Tag Labeling Kit (RED-tris-NTA 2nd Generation kit, NanoTemper). The labeled protein was dissolved in a buffer containing PBS ...
-
bioRxiv - Biophysics 2023Quote: ... 10 µL samples were aspirated in capillaries (TY-C001, Nanotemper, Germany), and intrinsic fluorescence was measured at 350 nm and 330 nm while the temperature was ramped from 35 °C to 95 °C at a rate of 30 °C/min ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... 10 ul was sampled in a Monolith.NT115 capillary (NanoTemper MO-K022) and measurements were performed at 25°C using standard parameters ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... We used the Monolith Protein Labeling Kit RED-NHS 2nd Generation kit (NanoTemper MO- L011) to label ∼1 lysine per Fcy1 monomer with a fluorophore following the manufacturer’s instruction ...
-
DTX3L and USP28 fine-tune DNA double strand repair through mutual regulation of their protein levelsbioRxiv - Biochemistry 2023Quote: ... 10 μl were loaded onto the Monolith NT.115 Premium Capillaries (NanoTemper). The MST signal was recorded with NT.Control v2.1.31 software and data was fitted to a Kd model with MO.Affinity Analysis v2.3 software.
-
bioRxiv - Biochemistry 2019Quote: ... was labeled with Monolith His-Tag Labeling Kit RED-tris-NTA kit (NanoTemper Technologies, München, Germany). Briefly ...
-
bioRxiv - Biophysics 2021Quote: ... 10 mM NaCl and transferred to capillaries (Standard treated, NanoTemper Technologies GmbH, Germany), measurements were performed at 37 °C with a constant blue LED power of 20% and at MST infrared laser powers of 40 % to induce thermophoretic motion ...
-
bioRxiv - Biophysics 2021Quote: ... 10 μl samples were manually loaded into nanoDSF Grade Standard Capillaries (NanoTemper Technologies) and transferred to a Prometheus NT.48 nanoDSF device (NanoTemper Technologies) ...
-
bioRxiv - Molecular Biology 2020Quote: ... We measured the fluorescence signal from Gαi1β1γ1 by using the Monolith His-Tag Labeling Kit RED-tris-NTA 2nd Generation kit (NanoTemper Technologies). The samples were prepared in a buffer containing 20 mM sodium phosphate (pH 6.9) ...
-
bioRxiv - Microbiology 2023Quote: ... + 0.5% DDM and was labeled using a His-Tag Labeling Kit RED-tris-NTA 2nd Generation Kit (NanoTemper) via the manufacturers protocol in 1.7 ml low-adhesion tubes ...
-
bioRxiv - Biochemistry 2019Quote: MST was measured on 10 μl reactions using standard capillaries (MO-K022, NanoTemper Technologies) on a Monolith NT.115 (NanoTemper Technologies ...
-
bioRxiv - Biophysics 2021Quote: 6xHis-RAD51 was labelled with the Monolith His-Tag Labeling Kit RED-tris-NTA 2nd Generation kit (NanoTemper Technologies), which specifically recognizes the hexahistidine tail of the recombinant protein.
-
bioRxiv - Neuroscience 2023Quote: ... Control experiments included measurements of the binding of the RED-tris-NTA dye to His-DJ-1 and of a dye-labeled AptamerCy5 to AMP using a manufacturer kit (Monolith NT.115 Control Kit RED, NanoTemper).
-
bioRxiv - Microbiology 2024Quote: ... and the NHS-red-tag kit (Nanotemper, Germany) was used to label ConA (Sigma ...
-
bioRxiv - Biochemistry 2020Quote: ... pH 8.2) was mixed with 10 μL dye (Dye RED-NHS 2nd Generation (Nanotemper MO-L011)) solution (300 μM ...
-
bioRxiv - Immunology 2022Quote: ... and ∼10 µl of each diluted sample (in duplicates) was loaded into NanoDSF capillaries (NanoTemper Technologies). The temperature was raised from 20°C to 95°C at 1°C/min rate ...
-
bioRxiv - Microbiology 2020Quote: ... Each protein (10 μM) was labeled with NT-647-NHS reactive dye (30 μM) (Nanotemper, Germany), which reacted efficiently with the primary amines of the proteins to form a stable dye protein conjugate ...
-
bioRxiv - Biophysics 2020Quote: ... pH 8.2) was mixed with 10 µl of 300 µM NT647-N-hydroxysuccinimide fluorophore (NanoTemper Technologies) and incubated in the dark for 30 min at room temperature ...
-
bioRxiv - Biochemistry 2023Quote: The BD5.1 protein was labelled with the Monolith His-Tag Labeling Kit (RED-tris-NTA 2nd Generation kit, NanoTemper Technologies, Catalog# MO-L018) according to the manufacturer’s protocol ...
-
bioRxiv - Biophysics 2021Quote: ... 10 μl of 100 nM labeled NHR2 in MST-buffer (included with the capillary set from NanoTemper) was mixed with 10 μl unlabeled NHR2 with concentrations ranging from 10.3 nM to 337.5 μM ...
-
bioRxiv - Microbiology 2020Quote: ... Monolith His-Tag Labeling kit (MO-L018) was from NanoTemper Technologies.
-
bioRxiv - Biochemistry 2021Quote: ... Thermophoresis data were analyzed when fluorescence signals lies within the 10% acceptance range using MO Affinity Analysis software V2.1.2 (Nanotemper). Data were plotted using GraphPad Prism 4.0 software and fitted with nonlinear equation.
-
bioRxiv - Molecular Biology 2023Quote: ... The mixtures were incubated at room temperature for 10 min and transferred to 16 standard capillaries (Nanotemper, Germany). Data were acquired using medium MST power ...