Labshake search
Citations for Agilent :
1 - 50 of 2963 citations for Fish Sperm DNA since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2023Quote: ... Salmon sperm DNA (Agilent technologies, Cat #201190) was boiled for 5 min and then stored on ice ...
-
bioRxiv - Cancer Biology 2020Quote: ... 0.1 mg/ml salmon sperm DNA (Agilent 201190), 1% SDS ...
-
bioRxiv - Molecular Biology 2022Quote: ... 200 mg/L sonicated salmon sperm DNA (Agilent), 2 g/L BSA ...
-
bioRxiv - Biochemistry 2020Quote: ... and 0.1 mg ml−1 sonicated salmon sperm DNA (Stratagene) for 1h at 80 °C (for DNA/LNA probes ...
-
bioRxiv - Biophysics 2021Quote: ... 700 μL of 10mg/mL boiled salmon sperm DNA (Agilent Genomics) was added to each tube of cells ...
-
bioRxiv - Systems Biology 2020Quote: ... and 100 μg/mL sonicated salmon sperm DNA (Agilent 201190-81) in 2X SSC ...
-
bioRxiv - Cancer Biology 2020Quote: ... 0.5 mg/ml salmon sperm DNA (Agilent, Santa Clara, California, 201190), 1% SDS) ...
-
bioRxiv - Biophysics 2022Quote: ... 175 μL of 10mg/mL boiled salmon sperm DNA (Agilent Genomics) was added to each tube of cells ...
-
bioRxiv - Biochemistry 2023Quote: ... and 0,1 mg/mL sonicated salmon sperm DNA (Agilent Technologies, #201190)) at 50 °C for 1 h ...
-
bioRxiv - Biophysics 2023Quote: ... 175 μL of 10mg/mL boiled salmon sperm DNA (Agilent Genomics) and 3.5 μg of plasmid library were added to each tube of cells and mixed gently ...
-
bioRxiv - Biochemistry 2022Quote: ... Crosslinked DNA was precipitated by adding 1.5 μL 10 mg/mL sonicated salmon sperm DNA (Agilent), 33 μL 3 M sodium acetate ...
-
bioRxiv - Cell Biology 2022Quote: ... and 500 µL boiled sonicated salmon sperm DNA (cat. no. 201190-81, Agilent) for a minimum of 30 minutes at 68°C ...
-
bioRxiv - Cell Biology 2022Quote: ... Pellets were then resuspended in 100µl 1M sorbitol containing linearised DNA and sonicated salmon sperm DNA (Agilent Technologies). Cells were incubated on ice for 30 minutes ...
-
bioRxiv - Cell Biology 2022Quote: ... and 0.05 mg/mL sonicated salmon sperm single stranded DNA (Stratagene, La Jolla, California) in PBS) ...
-
bioRxiv - Systems Biology 2023Quote: ... 175 ul of 10 mg/mL salmon sperm DNA (Agilent Technologies, Santa Clara, CA) were added ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then washed in lithium acetate Tris-EDTA and incubated in 100µl of the same buffer for 10 minutes at room temperature together with 5µg of linear DNA and 50µg of sonicated salmon sperm DNA (Agilent Technologies). 240µl of PEG-lithium acetate Tris-EDTA was added and cell suspension was mixed by swirling with a pipette tip ...
-
bioRxiv - Systems Biology 2023Quote: ... 350 μl of 10 mg/mL pre-boiled salmon sperm DNA (Agilent Technologies, Santa Clara, CA) were added and mixed thoroughly with the cells before adding 7 μg of the final library to each replicate and mixing by inversion ...
-
bioRxiv - Cell Biology 2021Quote: ... Telomere FISH was conducted using the Telomere PNA FISH Kit/Cy3 (Dako, K5326) according to the protocol provided by the supplier.
-
bioRxiv - Genetics 2019Quote: ... including 50 μl of recently boiled-then-snap-chilled 10 mg/ml ssDNA (salmon sperm DNA Agilent # 201190), 1 mg vector ...
-
bioRxiv - Cancer Biology 2023Quote: FISH assay was performed on tissue microarrays using the Histology FISH accessory kit (K579911-2, Dako, Agilent Technologies ...
-
bioRxiv - Cancer Biology 2019Quote: 3D-FISH was performed using the Dako FISH Histology accessory kit from Agilent (Catlog no: K579911-5) as per manufacturer guidelines ...
-
bioRxiv - Genomics 2020Quote: ... cells were treated at a final concentration of 10μg/ml Poly(I:C) or sonicated salmon sperm DNA (Agilent, Stockport, UK) for 72hrs ...
-
bioRxiv - Cell Biology 2021Quote: ... The Telomere PNA FISH Kit/FITC (DAKO) was used to probe for telomeres ...
-
bioRxiv - Genomics 2020Quote: ... and FISH Wash Buffer 2 (Agilent, G9402A) at room temperature for 1 min ...
-
bioRxiv - Cell Biology 2024Quote: ... Blocking was done in Primary Blocking Buffer (10% donkey serum, 0.1% saponin, 0.05 mg/mL sonicated salmon sperm DNA (Stratagene, La Jolla, California) in PBS for 1 hour at room temperature ...
-
bioRxiv - Cancer Biology 2020Quote: The following FISH probes were acquired from Agilent Technologies ...
-
bioRxiv - Cancer Biology 2023Quote: FISH assay was performed on tissue microarrays using the Histology FISH accessory kit (K579911-2, Dako, Agilent Technologies, Santa Clara, CA, USA) according to the manufacturers’ instructions ...
-
bioRxiv - Genomics 2020Quote: ... Probe sets used for FISH were designed by Agilent technologies using their standard procedures against genomic regions defined in Table S12 ...
-
bioRxiv - Cancer Biology 2020Quote: FISH was performed following established protocols provided by Agilent Technologies ...
-
bioRxiv - Cancer Biology 2020Quote: ... was performed on 3-μm thick tissue sections using split signal FISH DNA probes for BCL2/18q21 (probe Y5407; DAKO A/S), BCL6/3q27 (probe Y5408 ...
-
bioRxiv - Genomics 2020Quote: ... coverslips were washed with FISH Wash Buffer 1 (Agilent, G9401A) at 73 °C for 2 min on a shaking incubator at 300 rpm ...
-
bioRxiv - Genetics 2019Quote: ... telomeres were labelled using the Telomere PNA FISH Kit/Cy3 (Agilent), following the manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2020Quote: ... FISH RAMP1 red for the RAMP1 gene (#G110996X-8, Agilent Technologies), SureFISH chr2 CEP 448kb green for the centromere of chromosome 2 (#G101089 ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... using a telomere PNA (peptide nucleic acid) FISH Kit/FITC (DAKO, Denmark) according to the manufacturer’s protocol ...
-
bioRxiv - Cell Biology 2023Quote: The TeloFISH was carried out using the Telomere PNA FISH Kit/Cy3 (Dako), following the manufacturer instructions ...
-
bioRxiv - Cancer Biology 2022Quote: ... telomere interphase FISH was performed using fluorescein isothiocyanate-labeled PNA telomere probe (DAKO, Cat. # 5327) following the manufacturer’s protocol ...
-
bioRxiv - Molecular Biology 2023Quote: ... range: 7.0–8.3) and 8.8 ± 0.6 (whole fish, range: 7.6–9.5) using TapeStation (Agilent Technologies). Although eRNA samples were somewhat degraded as indicated by lower RINe ...
-
bioRxiv - Cell Biology 2022Quote: ... a 5 μl drop of ice-cold sperm (1.2×105/ μl) was deposited on parafilm at room temperature and irradiated in a Stratalinker 1800 (Stratagene) with ~700 μJ/m2 UV ...
-
bioRxiv - Cell Biology 2024Quote: ... 2 million sperm per well was placed into concanavalin A (0.05 mg/mL) coated 96-well plate for Seahorse XFe96 (Agilent). Mitochondrial activity (OXPHOS ...
-
bioRxiv - Cancer Biology 2019Quote: Custom FISH probes targeting MYC promoter and enhancer were designed using the SureDesign custom oligo design tool from Agilent with homology to the regions of interest mined from the hg19 genome build using the default parameters of the SureDesign tool ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... Telomeric FISH using a Cy3-labelled PNA probe was performed according to the manufacturer’s instructions (Telomere PNA FISH Kit/Cy3, Dako), all other methods including the cell cultivation followed the detailed protocols available in Supplementary Data of Altmanová et al ...
-
bioRxiv - Evolutionary Biology 2022Quote: Telomeric (TTAGGG)n repeats were detected by FISH using a commercial telomere PNA probe directly labelled with Cy3 (DAKO, Glostrup, Denmark) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2020Quote: ... sealed with adhesive and incubated for 10 min at 65°C and overnight at 37°C on a FISH-hybridizer (Dako; Agilent Technologies, Santa Clara, CA). The slides were then immersed in a series of baths with SSC buffer at different concentrations of 4× ...
-
bioRxiv - Microbiology 2020Quote: ... sealed with adhesive and incubated for 10 min at 65°C and overnight at 37°C on a FISH-hybridizer (Dako; Agilent Technologies, Santa Clara, CA). The slides were then immersed in a series of baths with SSC buffer at different concentrations of 4× ...
-
bioRxiv - Microbiology 2021Quote: ... 120 μg of genomic DNA was amplified using DNA Herculase II Fusion DNA polymerase (Agilent) in the presence of 2% DMSO ...
-
bioRxiv - Genetics 2019Quote: ... DNA integrity was assessed using genomic DNA ScreenTape (Agilent) and a TapeStation 2200 (Agilent).
-
bioRxiv - Bioengineering 2021Quote: ... DNA was ligated using T4 DNA ligase (Agilent technologies, USA) according to the manufacturer’s recommendations ...
-
bioRxiv - Cancer Biology 2021Quote: ... DNA was amplified using Herculase II Fusion DNA Polymerase (Agilent) according to the manufacturer’s conditions with 2 μl Herculase II and 2.5 mM MgCl2 ...
-
bioRxiv - Genomics 2022Quote: ... DNA libraries were loaded on a ZAG DNA analyzer (Agilent) for quality control ...
-
bioRxiv - Microbiology 2022Quote: ... DNA quality was determined using TapeStation Genomic DNA Screentape (Agilent) and quantified using a NanoDrop 2000 (Thermo Scientific) ...