Labshake search
Citations for Phenomenex :
1 - 25 of 25 citations for Yeast Extracts since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... The extracts were transferred to LC vials (Phenomenex, CA) prior to UPLC-MS/MS analysis ...
-
bioRxiv - Neuroscience 2020Quote: The tissue extracts were injected onto a Kinetex analytical column (Phenomenex, 100 × 2.1 mm ...
-
bioRxiv - Physiology 2023Quote: ... injecting 1 μl of the methanolic serum extracts onto a Kinetex (Phenomenex) C18 column (100 Å ...
-
bioRxiv - Microbiology 2023Quote: ... The extract was separated by reverse-phase high performance liquid chromatography (RP-HPLC, Phenomenex Luna 5 μm C18 ...
-
bioRxiv - Plant Biology 2020Quote: ... A total of 10 µL of extract was applied to a Kinetex (Phenomenex, Torrance, CA, USA) C18 column (50 mm length ...
-
bioRxiv - Biochemistry 2023Quote: ... Ten microliters of sample extracts were loaded onto a Kinetex XB-C18 column (150x2.1 mm i.d., 1.7µm – Phenomenex). Samples were analyzed using a 5 minutes method as described (Nemkov et al ...
-
bioRxiv - Cancer Biology 2023Quote: ... The extract was loaded onto the Phree Phospholipid Removal Tabbed 1mL tube (Phenomenex, #8B-S133-TAK) and centrifuged at 4°C ...
-
bioRxiv - Microbiology 2019Quote: ... The peptide extracts were desalted on C18 column (Strata™XL 100 μm Polymeric Reversed Phase – Phenomenex).
-
bioRxiv - Biochemistry 2019Quote: ... the extract was further filtered through syringe filter (0.22 mm nylon syringe filters; Phenomenex, Torrance, CA, USA). The separation of phenolic compounds was performed in a HPLC (Agilent 1220 ...
-
bioRxiv - Immunology 2022Quote: ... Ten microliters of sample extracts were loaded onto a Kinetex XB-C18 column (150 × 2.1 mm i.d., 1.7 μm – Phenomenex). A 5 min gradient (5%–95% B ...
-
bioRxiv - Molecular Biology 2023Quote: ... The reversed phase separation was performed with 2 µL lipid extract that was injected on a Kinetex C8 LC Column (50 x 2.1 mm, 2.6 um, Phenomenex) maintained at 50°C ...
-
bioRxiv - Microbiology 2019Quote: Biological extracts were pooled (1mg/mL) and run on a Bruker Impact II qTOF with a C18 UPLC (Phenomenex) in two technical replicates ...
-
bioRxiv - Biochemistry 2019Quote: ... the crude extract was purified by solid-phase extraction using a 30 mg Strata-X polymeric reversed-phase column (Phenomenex). The extract was applied to the column as an aqueous solution of 5% acetonitrile (v/v ...
-
bioRxiv - Biochemistry 2020Quote: ... the crude extract was purified by solid-phase extraction using a 30 mg Strata-X polymeric reversed-phase column (Phenomenex). The dried extract was dissolved in 2 mL of an aqueous solution of 5% acetonitrile (v/v ...
-
bioRxiv - Microbiology 2020Quote: ... 10 µL of extracts were chromatographed on Kinetex C18 column (2.6 µm C18 100 Å, 100 x 2.1 mm) (Phenomenex, USA) with column temperature set at 50°C and auto-sampler temperature was set at 4°C ...
-
bioRxiv - Neuroscience 2022Quote: ... Standards and synaptosome extracts (20 µl each) were injected onto a Luna NH₂ column (3 µm, 2.0 mm × 150 mm) (Phenomenex, Australia) maintained at room temperature ...
-
bioRxiv - Microbiology 2019Quote: ... was isolated from the crude extract of 1187 cultivation by preparative HPLC (gradient 65% to 100% methanol in 25 min, column Phenomenex Luna C18 250×21 mm ...
-
bioRxiv - Microbiology 2020Quote: ... as follows: the aqueous extract was loaded onto a reversed-phase SPE cartridge (Phenomenex Strata-X: 3 ml, 30 mg) that had previously been conditioned with methanol (3 ml ...
-
bioRxiv - Cell Biology 2023Quote: ... Ten microliters of lipid extract were injected into a hydrophilic interaction liquid chromatography (HILIC) column (2.6um Kinetex HILIC 100Å, 50×4.6mm, Phenomenex, Torrance, USA). Lipid classes were separated by gradient elution using an Agilent 1290 InfinityII UPLC (Agilent ...
-
bioRxiv - Cell Biology 2023Quote: ... lipid extract were separated on a 1.7 μm C18 (150 mm□×□2.10 mm, 100 Å) UHPLC column (Kinetex, Phenomenex, Torrance, CA) heated at 55 °C ...
-
bioRxiv - Microbiology 2024Quote: ... The filtered extract was directly injected onto a reversed-phase preparative high-performance liquid chromatography (HPLC) column (Phenomenex Luna C18 (2), 250 × 21.2 mm ...
-
bioRxiv - Plant Biology 2020Quote: ... Lipid extracts were first separated on a Kinetex™ (Kinetex, Atlanta, GA, USA) C182.1×150 mm 1.7 μm column (Phenomenex, Torrance, CA, USA). Two solvent mixtures ...
-
bioRxiv - Genomics 2020Quote: ... 10 μL of the lipid extract was injected onto a Kinetex C18 column (50 mm × 2.1 mm, particle size: 5 μm; Phenomenex, Torrance, CA, USA). The mobile phase consisted of 5-mM ammonium formate in water (A ...
-
bioRxiv - Microbiology 2019Quote: ... was isolated from extracts of PDA and 1187 cultivations by preparative HPLC (gradient 50% to 100% acetonitrile in 25 min, column Phenomenex Luna C18 250×21mm), (gradient 80% to 100% acetonitrile in 25 min ...
-
bioRxiv - Plant Biology 2023Quote: ... Aliquots of 10 µL aliquotof protein extracts were transferredinto two 96-well plates (Strata 96-wellcollection plate, 350 µL conical polypropylene, Phenomenex, Lane Cove, NSW, Australia), diluted 6 times with 50 mM ammonium bicarbonate and digested with 5 µL aliquots of the trypsin/Lys-C solution prepared earlier ...