Labshake search
Citations for Phenomenex :
1 - 50 of 215 citations for Mono 2 Carboxymethyl Hexyl Phthalate Cp 95% 13C4 99% Dehp Metabolite Iv 100Ug Ml In Mtbe since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Synthetic Biology 2024Quote: ... Metabolites were separated with a Luna NH2 column (100 mm × 2 mm, 3 μm particle size, Phenomenex). The column was maintained at 15℃ with a solvent flow rate of 0.3 mL min−1 ...
-
bioRxiv - Plant Biology 2021Quote: ... Separation of metabolites was performed using a Luna C18 column (Phenomenex; 150 × 2 mm, 3 μm particle size). The mobile phase consisted of 97:3 water:methanol with 10 mM tributylamine and 15 mM acetic acid (solvent A ...
-
bioRxiv - Cell Biology 2023Quote: Metabolite separation was performed using a Luna-HILIC column (Phenomenex) on an UltiMate-3000 TPLRS LC ...
-
bioRxiv - Systems Biology 2022Quote: ... RP-HPLC purification was performed on a Shimadzu LC-8A system equipped with a Rheodyne 3725i preparative sample injector (20 mL loop) and a semi-prep Luna 5 μm Phenyl-Hexyl RP-HPLC column (Phenomenex 00G-4257-P0-AX; 5 μm, 100Å; 2.1 x 25cm). The sample was eluted using a 15 – 40 % B gradient over 50 min at a flow rate of 25 mL/min at 60 °C (buffer A ...
-
bioRxiv - Microbiology 2019Quote: ... as well as a Kinetex Phenyl-hexyl column (50 × 2.1 mm, 1.7 µm, 100 Å, Phenomenex, for phenazine-1-carboxylic acid). Elution gradient ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... The LC-MS-MS method used a Kinetex 2.6 μm Phenyl-Hexyl 100Å LC Column (50 x 4.6 mm; Phenomenex, Inc., Torrance, CA) heated to 35°C ...
-
bioRxiv - Immunology 2021Quote: Metabolites were analyzed using reverse-phase UHPLC (C18 Hydro-RP column; Phenomenex) coupled to an Exactive Plus orbitrap MS (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2019Quote: ... Metabolites were separated using a Synergi 4µ Fusion-RP 80A column (100 × 4.6 mm, Phenomenex) on Agilent’s 1290 infinity series UHPLC system coupled to the mass spectrometer ...
-
bioRxiv - Plant Biology 2020Quote: ... The metabolites were separated on Kinetex EVO C18 column (2.6 μm, 150 × 2.1 mm, Phenomenex). Mobile phases consisted of A ...
-
bioRxiv - Synthetic Biology 2021Quote: ... Metabolites were separated using a Rezex™ ROA-Organic Acid H+ (8%) LC Column (Phenomenex) at 35 °C ...
-
bioRxiv - Biochemistry 2019Quote: Strata-X (2 g/12 mL, Phenomenex) solid phase extraction cartridges containing surface modified styrene divinylbenzene were wrapped in aluminum foil to omit light ...
-
bioRxiv - Systems Biology 2019Quote: ... Metabolites were separated on a Luna 3 µm NH2 100 Å (150 × 2.0 mm) column (Phenomenex). The flowrate was 300 µL/min ...
-
Inhibition of nucleotide synthesis promotes replicative senescence of human mammary epithelial cellsbioRxiv - Systems Biology 2019Quote: ... Metabolites were separated on a Luna 3 µm NH2 100 Å (150 × 2.0 mm) column (Phenomenex). The flowrate was 300 µl/min ...
-
bioRxiv - Systems Biology 2021Quote: ... Metabolites were separated on a Luna 3 µm NH2 100 Å (150 × 2.0 mm) column (Phenomenex). The flowrate was 300 µl/min ...
-
bioRxiv - Microbiology 2020Quote: ... Metabolite separation was performed with a C18 column (Phenomenex Hydro-RP; cat. No 00D-4387-B0) using a 25 minute gradient of A ...
-
bioRxiv - Systems Biology 2019Quote: ... Metabolites were separated on a Luna 3 μm NH2 100 Å (150 × 2.0 mm) column (Phenomenex). The flowrate was 300 μl/min ...
-
bioRxiv - Cell Biology 2020Quote: ... Metabolites were separated on a Luna 3 μm NH2 100 Å (150 × 2.0 mm) column (Phenomenex). The flowrate was 300 μl/min ...
-
bioRxiv - Synthetic Biology 2022Quote: ... Gas tight vials (2 mL) were from Phenomenex, and gas sample canisters were from LabCommerce.
-
bioRxiv - Biochemistry 2022Quote: ... extracted metabolites were separated using a Synergi 4-μm Fusion-RP 80 Å (150*4.6 mm, Phenomenex) LC column on Shimadzu Nexera UHPLC system ...
-
bioRxiv - Biochemistry 2024Quote: ... Metabolites were separated using a Luna 5 μm C5 100 Å LC column (Phenomenex 00D-4043-E0). Mobile phase A was 95% (v/v ...
-
bioRxiv - Synthetic Biology 2024Quote: ... All vials (2 mL) and caps were from Phenomenex.
-
bioRxiv - Microbiology 2021Quote: ... Metabolite separation was performed with a Gemini C18 column (150 x 4.6 mm, 110 Å, 5 μm; Phenomenex) at 37 °C with a flow rate of 0.2 ml/min using a 45-min gradient program as described in [Gisin ...
-
bioRxiv - Microbiology 2023Quote: ... Metabolite separation was achieved with a Gemini C18 column (150 by 4.6 mm, 110 Å, 5 μm; Phenomenex) at 37°C with a flow rate of 0.2 ml/min in accordance with a previously described 45 min gradient program40 with small modifications ...
-
bioRxiv - Microbiology 2023Quote: ... Metabolites were separated on a Luna 3 μm NH2 100 NH2 100Å (150 x 2.0 mm) column (Phenomenex). The flow rate was 0.3 mL/min ...
-
bioRxiv - Molecular Biology 2023Quote: ... Metabolites were separated on a Luna 3 μm NH2 100 NH2 100A° (150 x 2.0 mm) column (Phenomenex), with the flow rate of 0.3 mL/min ...
-
bioRxiv - Developmental Biology 2024Quote: ... metabolites were separated using a Phenomenex Gemini C6-Phenyl (3µm, 100 x 2mm) column (Phenomenex, Torrance, CA, USA) via a gradient method consisting of mobile phase A ...
-
bioRxiv - Neuroscience 2022Quote: ... Neurotransmitters and their metabolites were separated on a Luna 100 × 3.0 mm C18 3 μm HPLC reversed-phase column (Phenomenex). The mobile phase consisted of 75 mM NaH2PO4 ...
-
bioRxiv - Plant Biology 2023Quote: IAA metabolites were separated on a Kinetex EVO C18 column (2.6 µm, 150 × 2.1 mm, Phenomenex, Torrance, CA, USA), flow rate 0.3ml/min ...
-
bioRxiv - Biochemistry 2023Quote: Quantification of energy metabolites and cofactors was performed using a cyano-phase LUNA column (50mm x 4.6mm, 5 µm; Phenomenex) with a 5.5 min run in negative ion mode with two separated runs ...
-
bioRxiv - Physiology 2023Quote: ... Separation of metabolites was conducted using a Luna 5 μm C5 100 Å LC column (Phenomenex 00B-4043-E0) with reverse phase chromatography ...
-
bioRxiv - Physiology 2023Quote: ... Separation of metabolites was conducted using a Luna 5 μm NH2 100 Å LC column (Phenomenex 00B-4378-E0) with normal phase chromatography ...
-
bioRxiv - Microbiology 2022Quote: ... 1 mL of bacterium suspension was transferred into 2 mL glass vials (AR0-37K0-13, Phenomenex) and sealed with designated caps (AR0-5760-13 ...
-
bioRxiv - Systems Biology 2023Quote: ... Metabolites were separated on Synergi 4-μm Fusion-RP 80 Å (150 × 4.6 mm) LC column (Phenomenex, 00F-4424-E0) using the Waters Acquity UPLC system ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... PFAS metabolites were separated with a Phenomenex Kinetex PS C18 100A (2.6μm, 100 x 4.6mm) column (Phenomenex, Torrance, CA, USA) via a gradient method consisting of mobile phase A ...
-
bioRxiv - Microbiology 2021Quote: ... prior to the analysis of liquid metabolites using a Shimadzu high-performance liquid chromatograph (HPLC) equipped with Rezex RHM-Monosaccharide H+ column (Phenomenex, USA) as described in Okonkwo et al ...
-
bioRxiv - Cancer Biology 2022Quote: ... Quantification of different metabolites was performed using a cyano-phase LUNA column (50mm x 4.6mm, 5 µm; Phenomenex, Torrance, CA, USA) by a 5 min run in negative ion mode ...
-
bioRxiv - Physiology 2023Quote: ... Measurement of energy metabolites and cofactors was performed by using a cyano-phase LUNA column (50 mm × 4.6 mm, 5 µm; Phenomenex, Bologna, Italy), maintained at 53°C ...
-
bioRxiv - Biochemistry 2024Quote: ... The separation of polar metabolites was conducted using a Luna 5 μm NH2 100 Å LC column (Phenomenex 00B-4378-E0) with normal phase chromatography ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Metabolites were separated on a Phenomenex Kinetex PS C18 100A column (2.6 µm, 100 x 4.6 mm) (Phenomenex, Torrance, CA, USA) using a gradient method with mobile phase A (H2O + 20 mM ammonium acetate ...
-
bioRxiv - Systems Biology 2022Quote: ... Glass vials (2 mL) and caps used for soil incubations were from Phenomenex, and 3-oxo-C12-HSL was from Sigma-Aldrich ...
-
bioRxiv - Neuroscience 2023Quote: ... Dried metabolite pellets were reconstituted in 50% ACN and filtered using PHENEX-RC 4 mm syringe filter (Phenomenex, cat. no AF0-3203-52). Metabolites were separated using a Hydrophilic Interaction Liquid Chromatography (HILIC ...
-
bioRxiv - Neuroscience 2019Quote: ... and 2µl was injected onto a 50m x 0.25mm (5% phenyl-arylene, 95% dimethylsiloxane) column with a 0.25µm ZB-5MS stationary phase (Phenomenex, Macclesfield, UK). Full-scan spectra were collected at three scans per second over a range of 50 to 650 m/z ...
-
bioRxiv - Zoology 2022Quote: ... into an injector heated at 280 ºC in splitless mode and then in a column compound of 5% Phenyl - 95% Dimethylpolysiloxane (Zebron ZH-5HT inferno, 30 m × 0.25 mm × 0.25 µm, Phenomenex, Torrance, CA, USA). The gas vector was helium at 1.2 ml min-1 ...
-
bioRxiv - Plant Biology 2023Quote: ... and separated through a 3-min isocratic elution (5% acetonitrile, 95% water, 0.1% formic acid) on a 1.7 μm C18 column (Kinetex XB-C18, Phenomenex, Torrance, CA, USA) at 250 μL/min and 25°C ...
-
bioRxiv - Biophysics 2023Quote: ... Only peptides fractions with a purity of >95% were combined and the purity was determined by RP-HPLC on a Jupiter 4 μm Proteo 90 Å C12 (Phenomenex), an Aeris 3.6 μm 100 Å XB-C18 (Phenomenex ...
-
bioRxiv - Synthetic Biology 2022Quote: ... samples (soil and liquid culture) were added to 2 mL gas-tight vials (AR0-37L0-13, Phenomenex) and crimped with VEREX tops (AR0-5710-13 ...
-
bioRxiv - Microbiology 2023Quote: ... 5 min) and 2 mL were filtered (15 mm ∅, 0.2 µm regenerated cellulose filter, Phenomenex, Torrance, USA). Then ...
-
bioRxiv - Systems Biology 2020Quote: ... Soluble protein (250 μL, 2 mg/mL) was applied to a BioSep-SEC-s4000 gel filtration column (Phenomenex) equilibrated in PBS ...
-
bioRxiv - Systems Biology 2023Quote: ... 2 mg of cell lysate at 20 mg/mL was loaded onto a Yarra SEC-4000 column (Phenomenex 00H-4514-K0 ...
-
bioRxiv - Neuroscience 2022Quote: ... The filtered samples were transferred into 2 mL amber LC-MS vials (Phenomenex, Torrance, CA, USA; Cat #AR0-3911-13) with pre-slit caps (Phenomenex ...