Labshake search
Citations for Phenomenex :
1 - 50 of 345 citations for 7 Chloroquinoline 2 3 dicarboxylic acid since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2023Quote: ... A Luna C18(2) C8 column (3 μm, 2 mm × 50 mm, Phenomenex) was used ...
-
bioRxiv - Microbiology 2019Quote: ... Luna-NH2 column (3 μm, 150 × 2 mm, Phenomenex) was used flowing at 0.4 mL/min ...
-
bioRxiv - Neuroscience 2023Quote: ... The aminopropyl column (Luna 3 µm NH2, 2 × 100 mm, Phenomenex) was used for the chromatographic separation ...
-
bioRxiv - Microbiology 2024Quote: ... Sub-fraction 7 (25 mg) was subjected to reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 150 × 2 mm; Phenomenex, Torrence, CA), guard column (BDS-Hypersil-C18 ...
-
bioRxiv - Plant Biology 2021Quote: ... Secondary metabolites were separated on an Aqua 3 µm C18 column (150 x 2 mm, 3 µm particle size) equipped with a pre-column filter from Phenomenex. The mobile phase consisted of 1 mM aqueous ammonium acetate (A) ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... and 0.1% v/v trifluoroacetic acid and running through a C8 column (Eclipse XDB-C8, 3 μm, 3.0×100 mm, Phenomenex) at a flow rate of 0.6 mL/minute ...
-
bioRxiv - Neuroscience 2023Quote: ... LC Column (150 × 2 mm, 3 μm particle size; Phenomenex, 00F-4377-B0). Chromatographic separation was achieved using the following conditions ...
-
bioRxiv - Immunology 2021Quote: ... column Gemini 3 µM C18 HPLC column (150 × 2 mm ID, Phenomenex, Torrance, CA, USA) at 35°C ...
-
bioRxiv - Biochemistry 2022Quote: ... dried lipids were re-dissolved in 40% UPLC solvent B (90% 2-propanol/10% acetonitrile/0.1% formic acid/10 mM NH4HCO3) and transferred to silanized glass inserts (Phenomenex) using Hamilton syringes ...
-
bioRxiv - Genetics 2021Quote: ... equipped with a Gemini C18 (3 mm, 100 mm x 2 mm) analytical column (Phenomenex, USA). An isocratic elution was applied with 80% acetonitrile-20% water and flow rate was set at 200 µL/min ...
-
bioRxiv - Molecular Biology 2023Quote: ... chromatographic separation was performed on a Luna® NH2 column (100 mm × 2 mm, 3 μm; Phenomenex) maintained at 35°C using mobile phase A [2 mM ammonium acetate in dichloromethane/acetonitrile 7:93 (v/v)] and mobile phase B [2 mM ammonium acetate in water-acetonitrile 50:50 (v/v)] in the following gradient ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Metabolites were separated with a Luna NH2 column (100 mm × 2 mm, 3 μm particle size, Phenomenex). The column was maintained at 15℃ with a solvent flow rate of 0.3 mL min−1 ...
-
bioRxiv - Cell Biology 2019Quote: ... acidified with formic acid (final concentration 3%) and cleaned by reversed phase solid phase extraction (STRATA-X from Phenomenex, P/N 8B-S100-TAK) following the manufacturer’s instructions ...
-
bioRxiv - Plant Biology 2021Quote: ... Separation of metabolites was performed using a Luna C18 column (Phenomenex; 150 × 2 mm, 3 μm particle size). The mobile phase consisted of 97:3 water:methanol with 10 mM tributylamine and 15 mM acetic acid (solvent A ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 50 × 1 mm; Phenomenex, Torrence, CA) and SenCell (2 mm glassy carbon electrode ...
-
bioRxiv - Molecular Biology 2019Quote: ... 3 μm (2.1 × 150 mm) column with Security Guard (4 × 2 mm) at 40°C (Phenomenex, Cheshire, UK). The standards and the samples (5 μl injection volume ...
-
bioRxiv - Microbiology 2019Quote: ... A 70 μm × 150 mm Luna C18(2) reverse phase column (3 μm; 100-Å pore size; Phenomenex) was packed in-house ...
-
bioRxiv - Physiology 2020Quote: Samples were injected (10 μL) onto a Kinetex C18 column (150 × 3 mm; 2 μm, Phenomenex, Macclesfield, UK) at 40°C using a flow rate of 0.5 mL/min ...
-
bioRxiv - Microbiology 2022Quote: ... The column was a Gemini C18 (50 mm × 2 mm, 100 Å, particle size of 3-μm; Phenomenex). The mobile phases consisted of water (A ...
-
Systemic impact of the expression of the mitochondrial alternative oxidase on Drosophila developmentbioRxiv - Biochemistry 2022Quote: ... 10% of each sample was loaded onto a Luna NH2 (3 µm 100A, 150 mm x 2 mm, Phenomenex) column ...
-
bioRxiv - Microbiology 2021Quote: ... Five µl extracted samples were injected on the C18 column (Gemini, 3 µm, 2 x 150 mm, Phenomenex, CA) with the flow rate of 0.3 ml/min at 45°C ...
-
bioRxiv - Cell Biology 2021Quote: ... Analytes were separated on a Luna C18 column (30 × 2 mm, 3 μm, 100 Å; Phenomenex, Torrance, CA, USA). The mobile phase consisted of 2 mM ammonium acetate in 100% methanol ...
-
bioRxiv - Immunology 2020Quote: ... Glycolytic and TCA intermediates were separated on a Luna Amino (NH2) column (3 µm, 100A 2 × 150 mm, Phenomenex), that was maintained in a temperature-controlled chamber (37°C).
-
bioRxiv - Neuroscience 2021Quote: ... Samples were injected onto a Prodigy C18 column (100Å∼2 mm I.D., 3-µm particle size, Phenomenex, Torrance, CA, USA). In the tissue homogenates ...
-
bioRxiv - Cell Biology 2024Quote: ... and peptide mixtures were separated on an NX 3u Gemini C18 column (150 mm x 2 mm, particle size 3 µM, pore size 110Å; Phenomenex) operated at 40°C with a flow rate of 200 µl/min using an Ultimate 3000 HPLC system ...
-
bioRxiv - Biochemistry 2019Quote: ... and trap columns (2 cm × 150 µm i.d) were packed in-house with 3 µm Jupiter C18 particles (Phenomenex, Torrance, CA). The long analytical column was placed in a column heater (Analytical Sales and Services ...
-
bioRxiv - Biochemistry 2020Quote: ... the reaction mixture submitted to HPLC-HRMS analysis using a Shimadzu Prominence liquid chromatograph equipped with a Luna C18 column (3 μm, 150 × 2 mm, Phenomenex®) and coupled to a Bruker Daltonics microTOF-QII mass spectrometer fitted with an electrospray source operated in positive mode ...
-
bioRxiv - Neuroscience 2023Quote: ... and a C18 separating capillary column (75 µm × 15 cm) packed in-house with Luna 3 μm C18(2) bulk packing material (Phenomenex, USA). A 2-h liquid chromatography (LC ...
-
bioRxiv - Microbiology 2021Quote: ... Rezex RFQ-Fast Acid H+ (8%) (Phenomenex) was used as the column and placed at 80 °C ...
-
bioRxiv - Microbiology 2024Quote: ... All samples were then vortexed and centrifuged at 10,000 x g for 3 min at 4 ºC and then diluted 2-fold with buffer in conical polypropylene HPLC vials (Phenomenex, Torrance, CA) prior to mass spectrometry analysis.
-
bioRxiv - Microbiology 2023Quote: ... the column (Phenomenex, Rezex ROAOrganic Acid H+ (8%), LC column 300 x 7.8mm ...
-
bioRxiv - Cell Biology 2022Quote: LC–MS analysis was performed on an Agilent 6230 electrospray ionization–time-of-flight MS coupled to an Agilent 1260 HPLC equipped with a Luna 3 μm Silica LC Column (Phenomenex; 50 × 2 mm) using a binary gradient elution system where solvent A was chloroform/methanol/ammonium hydroxide (85:15:0.5 ...
-
bioRxiv - Cancer Biology 2022Quote: ... using a Gemini C18 column (250 mm × 3 mm, 3 μm, 110 Å; Phenomenex). Buffer A consisted of 20 mM ammonium formate pH 8.0 and Buffer B of 100% acetonitrile ...
-
bioRxiv - Plant Biology 2022Quote: ... The separation of the analytes was performed using a Gemini C18 column (50 mm × 2 mm, 110 Å and particle size 3 μm) (Phenomenex, Palo Alto, CA, USA). Mobile phases consisted of water (solvent A ...
-
bioRxiv - Bioengineering 2019Quote: ... using a RezexTM ROA-Organic Acid H+ (8 %) column (Phenomenex). References were purchased from Sigma Aldrich ...
-
bioRxiv - Microbiology 2019Quote: ... using a RezexTM ROA-Organic Acid H+ (8 %) column (Phenomenex). References were purchased from Sigma Aldrich ...
-
bioRxiv - Bioengineering 2020Quote: ... 3 μm particle size (Phenomenex, UK). Bexarotene (CAS ...
-
bioRxiv - Cell Biology 2020Quote: ... 3 μm (Phenomenex, Los Angeles, CA). The HPLC-reverse phase column was calibrated with acetyl-CoA (Sigma ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μm C-18 column (Phenomenex) kept at 35°C ...
-
bioRxiv - Immunology 2024Quote: ... 3 μm (Phenomenex, Los Angeles, California). The detailed protocol was described previously (44).
-
bioRxiv - Systems Biology 2023Quote: ... 4 3 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column ...
-
bioRxiv - Cell Biology 2021Quote: ... 3 μm column (Phenomenex, Torrance, CA, USA). Acetonitrile and 0.1% formic acid were applied for gradient elution with the flow rate of 500 µl/min ...
-
bioRxiv - Cell Biology 2022Quote: ... packed with 3 μm C18 resin (Phenomenex) using a gradient from 7% to 55% buffer B at a flow rate of 500 nL/min ...
-
bioRxiv - Developmental Biology 2022Quote: ... 3 μm particle size (Phenomenex, Torrance, CA)) column packed in-house in Pico-Frit (100 μm X 30 cm ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 µm particle size (Phenomenex, Terrence, USA) at a flow rate of 300 nL/min using a 120 min gradient of 12-45% mobile phase B (acetonitrile + 0.1% formic acid) ...
-
bioRxiv - Microbiology 2023Quote: ... and a Rezex ROA-Organic Acid H+ (300×7.8 mm; Phenomenex Inc.) column ...
-
bioRxiv - Bioengineering 2022Quote: ... The Rezex ROA-Organic Acid H+ (8%) column (Phenomenex Inc., Torrance, CA) was used and the columns were eluted with 5 mM H2SO4 at 50 °C ...
-
bioRxiv - Synthetic Biology 2023Quote: ... and Rezex ROA-Organic Acid H+ (8%) column (Phenomenex, Torrance, CA, USA). The column and detector were run at 50 °C ...
-
bioRxiv - Immunology 2022Quote: ... 300 × 7.8 mm i.d., 3 μm, 500 Å; SEC-3000, 300 × 7.8 mm i.d., 3 μm, 290 Å, Phenomenex, Netherlands) two-stage set-up was used ...