Labshake search
Citations for Phenomenex :
1 - 50 of 558 citations for 7 16 DIHYDROBENZO A BENZO 5 6 QUINO 3 2 I ACRIDINE 9 18 DIONE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2023Quote: ... 3 μm C-18 column (Phenomenex) kept at 35°C ...
-
bioRxiv - Molecular Biology 2024Quote: ... × 15 cm pulled tip C-18 column (Jupiter C-18 300 Å, 5 micron, Phenomenex). This system ran in-line with a Thermo Orbitrap Velos Pro hybrid mass spectrometer equipped with a nano-electrospray source (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2021Quote: ... x 15 cm pulled tip C-18 column (Jupiter C-18 300 Å, 5 micron, Phenomenex). This system runs in-line with a Thermo Orbitrap Velos Pro hybrid mass spectrometer ...
-
bioRxiv - Systems Biology 2022Quote: ... x 13.5 cm pulled tip C-18 column (Jupiter C-18 300 Å, 5 micron, Phenomenex). This system runs in-line with a Thermo Orbitrap Velos Pro hybrid mass spectrometer ...
-
Comparative Proteomic Study of Retinal Ganglion Cells Undergoing Various Types of Cellular StressorsbioRxiv - Molecular Biology 2023Quote: ... x 15 cm pulled tip C-18 column (Jupiter C-18 300 Å, 5 micron, Phenomenex). This system runs in-line with a Thermo Q Exactive HFx mass spectrometer ...
-
bioRxiv - Immunology 2023Quote: ... x 15 cm pulled tip C-18 column (Jupiter C-18 300 Å, 5 µm, Phenomenex). This system runs in-line with a Thermo Q Exactive HFx mass spectrometer ...
-
bioRxiv - Microbiology 2023Quote: ... digested samples were loaded onto a fused silica capillary column with a 5-μm electrospray tip and packed in house with 18 cm of Luna C18 3 μM particles (Phenomenex). The column was then placed in line with a Q-exactive mass spectrometer (ThermoFisher ...
-
bioRxiv - Molecular Biology 2021Quote: ... x 15 cm pulled tip C-18 column (Jupiter C-18 300 Å, 5 micron, Phenomenex, Torrance, CA). This system ran in-line with a Thermo Orbitrap Velos Pro hybrid mass spectrometer ...
-
bioRxiv - Biochemistry 2020Quote: ... Crude separation was achieved by using a RP-18 Strata column (500 mg/6 mL, Phenomenex). The following buffers were used sequentially for crude separation ...
-
bioRxiv - Systems Biology 2019Quote: ... The trap column was packed with 5 μm Aqua C-18 beads (Phenomenex) while the analytical column was packed with 1.9 μm diameter Reprosil-Pur C-18-AQ beads (Dr ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... C-18 (2) with TMS end capping) were purchased from Phenomenex (Torrance, CA). Lutetium-177 in the form of lutetium chloride (177Lu-LuCl3 ...
-
bioRxiv - Biochemistry 2019Quote: ... The trap column is packed with 5 µm Aqua C-18 beads (Phenomenex, www.phenomenex.com) while the analytical column is packed with 1.9 µm-diameter Reprosil-Pur C-18-AQ beads (Dr ...
-
bioRxiv - Systems Biology 2019Quote: ... The trap column was packed with 5 μm diameter Aqua C-18 beads (Phenomenex) to 2 cm ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Chromatographic separation was conducted on a LC C-18 column (50 × 3 mm, 1.7 μm, Phenomenex) at 30°C ...
-
bioRxiv - Cell Biology 2021Quote: ... 100-μm-inner diameter trap column packed with 5 μm-diameter Aqua C-18 beads (Phenomenex) and a 40-cm-long ...
-
bioRxiv - Neuroscience 2019Quote: ... Dialysates were injected into a 2.1 mm RP-18 column (Phenomenex, Gemini-NX 3 µm 100 × 2.00 mm) with a 65 μL sample loop ...
-
bioRxiv - Cancer Biology 2023Quote: ... A Luna C18(2) C8 column (3 μm, 2 mm × 50 mm, Phenomenex) was used ...
-
bioRxiv - Plant Biology 2020Quote: ... equipped with a photodiode array detector and separated using a Gemini C-18 column (150 × 2.00 mm, 5 μm; Phenomenex) with a flow rate of 0.5 mL per minute and the following solvents and binary gradient ...
-
bioRxiv - Microbiology 2019Quote: ... Luna-NH2 column (3 μm, 150 × 2 mm, Phenomenex) was used flowing at 0.4 mL/min ...
-
bioRxiv - Cancer Biology 2024Quote: ... Both cell and secretome samples were chromatographically separated on an emitter-tip column packed with 3 µM C-18 Luna material (Phenomenex, USA)) on an Ultimate 3000 uHPLC (Thermo Scientific ...
-
bioRxiv - Plant Biology 2023Quote: ... A SPE cartridge C-18 (Phenomenex) was conditioned with 4 mL of methanol (100% ...
-
bioRxiv - Cell Biology 2021Quote: ... self-packed with C-18 reverse-phase resin (Jupiter 5 um particles, 300 Å pore size; Phenomenex, Torrance, CA, USA) using a high- pressure packing cell on the Easy-nLC II system (Proxeon Biosystems ...
-
bioRxiv - Biochemistry 2021Quote: ... The samples were eluted on a C-18 Omega Polar HPLC column (Phenomenex, 250 × 4.6 mm, 5 mm particle size) using 50:50 acetonitrile:H2O for 3 min ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Ltd., Hachioji, Tokyo, Japan) using a Kinetex C-18 (5 μm, 250 × 4.6 mm) column (Phenomenex Inc., Torrance, CA, USA) and applying a gradient of 30–100% aqueous AcN in 30 min followed by 100% AcN for another 10 min at a flow rate of 1 mL/min.
-
bioRxiv - Cancer Biology 2022Quote: ... and 5 mg of C18 solid phase (3 μm, Durashell, Phenomenex). The HpHt column was sequentially washed with a series of 3 different solvents/solutions namely methanol ...
-
bioRxiv - Synthetic Biology 2023Quote: ... Isolation of all compounds was done using a semi-preparative RP-18 column (250 × 10.0 mm, 5 μm, Hyperclone ODS C18 column, Phenomenex, Aschaffenburg, Germany) operating with a flow rate of 4.8 mL/min ...
-
bioRxiv - Genetics 2023Quote: ... Separation of allantoin was performed on a Synergy Hydro-RP C-18 reversed-phase column (250 × 4.6 mm I.D., 5 m particle size) from Phenomenex (Torrance, CA, USA). Allantoin elution (at 4 min ...
-
bioRxiv - Cancer Biology 2023Quote: ... and the crude mixture was purified on a reversed-phase high-performance liquid chromatography (RP-HPLC) system using a preparative C-18 Phenomenex column (5 mm, 21.5 x 250 mm Phenomenex, Torrance, CA). The HPLC condition was gradient elution starting with 10% acetonitrile ...
-
bioRxiv - Systems Biology 2021Quote: ... and glycolysis cycle metabolites were identified by using 5 mM ammonium acetate in water pH 9.9 as buffer A and 100% acetonitrile as buffer B using a Luna 3 μM NH2 100 Å chromatography column (Phenomenex, Torrance, CA). The gradient used ...
-
bioRxiv - Neuroscience 2023Quote: ... The aminopropyl column (Luna 3 µm NH2, 2 × 100 mm, Phenomenex) was used for the chromatographic separation ...
-
bioRxiv - Microbiology 2024Quote: ... Sub-fraction 7 (25 mg) was subjected to reversed-phase semi-preparative HPLC (Phenomenex Luna C18 (2), 250 × 10 mm ...
-
bioRxiv - Developmental Biology 2020Quote: ... with C-18 reverse-phase material and high pressure packing cells (Jupiter 5 µm particles, 300 Å pore size; Phenomenex, Torrance, CA). LC-MS/MS data was acquired using a data-dependent top11 method combined with a dynamic exclusion window of 30 sec ...
-
bioRxiv - Cancer Biology 2023Quote: ... The reaction mixture was incubated for 12 min at 65 °C in a temperature-controlled heating block and purified on a RP-HPLC system using a semi-preparative C-18 Luna column (5 mm, 10 x 250 mm Phenomenex, Torrance, CA). The HPLC condition was gradient elution starting with 5% acetonitrile ...
-
bioRxiv - Cancer Biology 2023Quote: ... DMF was evaporated using a rotary evaporator under reduced pressure and the residual product was purified on a RP-HPLC system using a semi-preparative C-18 Luna column (5 mm, 10 x 250 mm Phenomenex, Torrance, CA). The HPLC condition was gradient elution started with 5% acetonitrile ...
-
bioRxiv - Cancer Biology 2023Quote: ... The reaction mixture was incubated at 65 °C for 30 min and then purified on a RP-HPLC system using a semi-preparative C-18 Luna column (5 mm, 10 x 250 mm Phenomenex, Torrance, CA). The HPLC gradient elution condition started with 5% acetonitrile ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 150 × 2 mm; Phenomenex, Torrence, CA), guard column (BDS-Hypersil-C18 ...
-
bioRxiv - Biochemistry 2021Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Biochemistry 2020Quote: ... followed by 3 cm of 5-μm Strong Cation Exchange material (Luna; Phenomenex), followed by 1 cm of 5-μm C18 RP ...
-
bioRxiv - Plant Biology 2021Quote: ... Secondary metabolites were separated on an Aqua 3 µm C18 column (150 x 2 mm, 3 µm particle size) equipped with a pre-column filter from Phenomenex. The mobile phase consisted of 1 mM aqueous ammonium acetate (A) ...
-
bioRxiv - Microbiology 2021Quote: ... on a C-18 reverse phase column (Phenomenex – Gemini), at 25°C ...
-
bioRxiv - Neuroscience 2023Quote: ... LC Column (150 × 2 mm, 3 μm particle size; Phenomenex, 00F-4377-B0). Chromatographic separation was achieved using the following conditions ...
-
bioRxiv - Microbiology 2024Quote: ... The active fractions 12-16 were combined and further fractionated using a reversed-phase preparative HPLC column (Phenomenex Luna C18 (2), 250 × 21.2 mm ...
-
bioRxiv - Neuroscience 2019Quote: ... 250 9 4.60 mm column (Phenomenex, Torrance, CA, USA) and an LC-4C electrochemical detector with glassy carbon electrode (BAS) ...
-
bioRxiv - Immunology 2023Quote: ... 125 pore size C-18 silica-bonded stationary phase (Phenomenex) and resolved using a 100-min gradient at the flow rate of 0.2 μl min−1 (3–33% B for 90 min ...
-
bioRxiv - Microbiology 2019Quote: Six tested HPLC HILIC stationary phases were: (I.) crosslinked diol (Luna HILIC diol, 100 × 4.6 mm, 5 µm, 200 Å; Phenomenex), (II. ...
-
bioRxiv - Immunology 2021Quote: ... column Gemini 3 µM C18 HPLC column (150 × 2 mm ID, Phenomenex, Torrance, CA, USA) at 35°C ...
-
bioRxiv - Immunology 2020Quote: ... and purified by HPLC using a C-18 Gemini column (Phenomenex) with a mobile phase of acetonitrile containing 0.1% TFA ...
-
bioRxiv - Neuroscience 2021Quote: ... which was subsequently purified by preparative HPLC (Phenomenex Luna 5 μm C18(2) 100 A° 250 × 10m m ...
-
bioRxiv - Neuroscience 2021Quote: ... At the time of arrival analytical HPLC (Phenomenex Luna 5 μm C18(2) 100 A° 250 × 4.6mm ...
-
bioRxiv - Neuroscience 2022Quote: ... 7 μL samples were injected onto a Gemini C18 column (150×4.60 mm, 110 Å, 5 μm particle size; Phenomenex, Torrance, CA, USA) connected to an electrochemical detector (Antec Leyden Intro ...