Labshake search
Citations for Phenomenex :
1 - 50 of 342 citations for 6 chloro 3 hydroxymethyl 1 3 benzoxazol 2 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2019Quote: ... Luna-NH2 column (3 μm, 150 × 2 mm, Phenomenex) was used flowing at 0.4 mL/min ...
-
bioRxiv - Cancer Biology 2023Quote: ... A Luna C18(2) C8 column (3 μm, 2 mm × 50 mm, Phenomenex) was used ...
-
bioRxiv - Plant Biology 2021Quote: ... Secondary metabolites were separated on an Aqua 3 µm C18 column (150 x 2 mm, 3 µm particle size) equipped with a pre-column filter from Phenomenex. The mobile phase consisted of 1 mM aqueous ammonium acetate (A) ...
-
bioRxiv - Neuroscience 2023Quote: ... The aminopropyl column (Luna 3 µm NH2, 2 × 100 mm, Phenomenex) was used for the chromatographic separation ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 50 × 1 mm; Phenomenex, Torrence, CA) and SenCell (2 mm glassy carbon electrode ...
-
bioRxiv - Neuroscience 2023Quote: ... LC Column (150 × 2 mm, 3 μm particle size; Phenomenex, 00F-4377-B0). Chromatographic separation was achieved using the following conditions ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 150 × 2 mm; Phenomenex, Torrence, CA), guard column (BDS-Hypersil-C18 ...
-
bioRxiv - Cancer Biology 2022Quote: ... using a Gemini C18 column (250 mm × 3 mm, 3 μm, 110 Å; Phenomenex). Buffer A consisted of 20 mM ammonium formate pH 8.0 and Buffer B of 100% acetonitrile ...
-
bioRxiv - Immunology 2021Quote: ... column Gemini 3 µM C18 HPLC column (150 × 2 mm ID, Phenomenex, Torrance, CA, USA) at 35°C ...
-
bioRxiv - Genetics 2021Quote: ... equipped with a Gemini C18 (3 mm, 100 mm x 2 mm) analytical column (Phenomenex, USA). An isocratic elution was applied with 80% acetonitrile-20% water and flow rate was set at 200 µL/min ...
-
bioRxiv - Bioengineering 2020Quote: ... 3 μm particle size (Phenomenex, UK). Bexarotene (CAS ...
-
bioRxiv - Cell Biology 2020Quote: ... 3 μm (Phenomenex, Los Angeles, CA). The HPLC-reverse phase column was calibrated with acetyl-CoA (Sigma ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μm C-18 column (Phenomenex) kept at 35°C ...
-
bioRxiv - Systems Biology 2023Quote: ... 4 3 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column ...
-
bioRxiv - Immunology 2024Quote: ... 3 μm (Phenomenex, Los Angeles, California). The detailed protocol was described previously (44).
-
bioRxiv - Molecular Biology 2023Quote: ... chromatographic separation was performed on a Luna® NH2 column (100 mm × 2 mm, 3 μm; Phenomenex) maintained at 35°C using mobile phase A [2 mM ammonium acetate in dichloromethane/acetonitrile 7:93 (v/v)] and mobile phase B [2 mM ammonium acetate in water-acetonitrile 50:50 (v/v)] in the following gradient ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Metabolites were separated with a Luna NH2 column (100 mm × 2 mm, 3 μm particle size, Phenomenex). The column was maintained at 15℃ with a solvent flow rate of 0.3 mL min−1 ...
-
bioRxiv - Cell Biology 2021Quote: ... 3 μm column (Phenomenex, Torrance, CA, USA). Acetonitrile and 0.1% formic acid were applied for gradient elution with the flow rate of 500 µl/min ...
-
bioRxiv - Cell Biology 2022Quote: ... packed with 3 μm C18 resin (Phenomenex) using a gradient from 7% to 55% buffer B at a flow rate of 500 nL/min ...
-
bioRxiv - Developmental Biology 2022Quote: ... 3 μm particle size (Phenomenex, Torrance, CA)) column packed in-house in Pico-Frit (100 μm X 30 cm ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 µm particle size (Phenomenex, Terrence, USA) at a flow rate of 300 nL/min using a 120 min gradient of 12-45% mobile phase B (acetonitrile + 0.1% formic acid) ...
-
bioRxiv - Plant Biology 2021Quote: ... Separation of metabolites was performed using a Luna C18 column (Phenomenex; 150 × 2 mm, 3 μm particle size). The mobile phase consisted of 97:3 water:methanol with 10 mM tributylamine and 15 mM acetic acid (solvent A ...
-
bioRxiv - Molecular Biology 2019Quote: ... 3 μm (2.1 × 150 mm) column with Security Guard (4 × 2 mm) at 40°C (Phenomenex, Cheshire, UK). The standards and the samples (5 μl injection volume ...
-
bioRxiv - Microbiology 2019Quote: ... A 70 μm × 150 mm Luna C18(2) reverse phase column (3 μm; 100-Å pore size; Phenomenex) was packed in-house ...
-
bioRxiv - Physiology 2020Quote: Samples were injected (10 μL) onto a Kinetex C18 column (150 × 3 mm; 2 μm, Phenomenex, Macclesfield, UK) at 40°C using a flow rate of 0.5 mL/min ...
-
bioRxiv - Microbiology 2022Quote: ... The column was a Gemini C18 (50 mm × 2 mm, 100 Å, particle size of 3-μm; Phenomenex). The mobile phases consisted of water (A ...
-
bioRxiv - Immunology 2022Quote: ... 300 × 7.8 mm i.d., 3 μm, 500 Å; SEC-3000, 300 × 7.8 mm i.d., 3 μm, 290 Å, Phenomenex, Netherlands) two-stage set-up was used ...
-
bioRxiv - Cancer Biology 2023Quote: ... Chromatographic separation of metabolites was achieved by hydrophilic interaction liquid chromatography (HILIC) using a Luna 3 NH2 column (150 mm x 2.1 mm, 3 μm, Phenomenex) in conjunction with a HILIC guard column (Phenomenex ...
-
bioRxiv - Systems Biology 2020Quote: ... samples were four-fold diluted with 1% TFA in isopropanol and loaded onto SDB-RPS cartridges (Strata™-X-C, 30 mg/ 3 ml or Strata™-X-C, 200 mg/ 6 ml, Phenomenex Inc.). Before peptide loading ...
-
bioRxiv - Neuroscience 2020Quote: ... this biphasic column was connected to a 100 μm inner diameter-fused silica capillary (Polymicro Technologies) analytical column with a 3 μm pulled tip packed with 10 cm of 3 μm C18 resin (Phenomenex). The entire three-phase column was then laced in line with a 1,200 quaternary HPLC pump (Agilent Technologies ...
-
bioRxiv - Immunology 2020Quote: ... Labelled peptides were solubilized in 20 mM ammonium formate (pH 8.0) and separated on a Gemini C18 column (250 × 3 mm, 3 μm C18 110 Å pore size; Phenomenex). Using a DGP-3600BM pump system equipped with a SRD-3600 degasser (Thermo-Fisher) ...
-
bioRxiv - Microbiology 2020Quote: ... and the trap columns (3 cm x 150 μm i.d) were packed in-house with 3 μm Jupiter C18 particles (Phenomenex, Torrance). The long analytical column was placed in a column heater (Analytical Sales and Services ...
-
Systemic impact of the expression of the mitochondrial alternative oxidase on Drosophila developmentbioRxiv - Biochemistry 2022Quote: ... 10% of each sample was loaded onto a Luna NH2 (3 µm 100A, 150 mm x 2 mm, Phenomenex) column ...
-
bioRxiv - Microbiology 2021Quote: ... Five µl extracted samples were injected on the C18 column (Gemini, 3 µm, 2 x 150 mm, Phenomenex, CA) with the flow rate of 0.3 ml/min at 45°C ...
-
bioRxiv - Cell Biology 2021Quote: ... Analytes were separated on a Luna C18 column (30 × 2 mm, 3 μm, 100 Å; Phenomenex, Torrance, CA, USA). The mobile phase consisted of 2 mM ammonium acetate in 100% methanol ...
-
bioRxiv - Immunology 2020Quote: ... Glycolytic and TCA intermediates were separated on a Luna Amino (NH2) column (3 µm, 100A 2 × 150 mm, Phenomenex), that was maintained in a temperature-controlled chamber (37°C).
-
bioRxiv - Bioengineering 2022Quote: ... 3 mm x 100 mm column (Phenomenex, USA) was used for LC separation of the molecules ...
-
bioRxiv - Biochemistry 2023Quote: ... The pooled sample was subject to fractionation using basic-pH reversed-phase liquid chromatography (LC) on a Gemini C18 column (250 mm × 3 mm, 3 μm, 110 Å; Phenomenex) on a Dionex Ultimate 3000 off-line LC system ...
-
bioRxiv - Neuroscience 2021Quote: ... Samples were injected onto a Prodigy C18 column (100Å∼2 mm I.D., 3-µm particle size, Phenomenex, Torrance, CA, USA). In the tissue homogenates ...
-
bioRxiv - Cell Biology 2024Quote: ... and peptide mixtures were separated on an NX 3u Gemini C18 column (150 mm x 2 mm, particle size 3 µM, pore size 110Å; Phenomenex) operated at 40°C with a flow rate of 200 µl/min using an Ultimate 3000 HPLC system ...
-
bioRxiv - Molecular Biology 2022Quote: ... 150 × 3 mm C18 column (Phenomenex, 00F-4462-Y0) equipped with a 3.0 mm safe-guard column (Phenomenex ...
-
bioRxiv - Plant Biology 2023Quote: ... a StrataX 30 mg/3 mL spe-column (Phenomenex) was used.
-
bioRxiv - Biochemistry 2019Quote: ... and trap columns (2 cm × 150 µm i.d) were packed in-house with 3 µm Jupiter C18 particles (Phenomenex, Torrance, CA). The long analytical column was placed in a column heater (Analytical Sales and Services ...
-
bioRxiv - Biochemistry 2020Quote: ... the reaction mixture submitted to HPLC-HRMS analysis using a Shimadzu Prominence liquid chromatograph equipped with a Luna C18 column (3 μm, 150 × 2 mm, Phenomenex®) and coupled to a Bruker Daltonics microTOF-QII mass spectrometer fitted with an electrospray source operated in positive mode ...
-
bioRxiv - Neuroscience 2023Quote: ... and a C18 separating capillary column (75 µm × 15 cm) packed in-house with Luna 3 μm C18(2) bulk packing material (Phenomenex, USA). A 2-h liquid chromatography (LC ...
-
bioRxiv - Microbiology 2022Quote: ... mass spectrometer fitted with an Exion UHPLC system having a Kinetex 2.6 mm hydrophilic interaction liquid chromatography (HILIC) column (100 Å particle size, 150 mm length, and 3 mm internal diameter; Phenomenex, Intek Chromasol Pvt. Ltd., India). Nitrogen was used as the nebulizer gas ...
-
bioRxiv - Biophysics 2022Quote: ... and separated by Phenomenex Yarra 3 μm SEC-4000 300 × 7.8 mm column (Phenomenex) in GF150 buffer (25 mM HEPES (pH 7.4) ...
-
bioRxiv - Physiology 2023Quote: A C18 column (2.1 x 150mm, Gemini, 3 μm, Phenomenex,) was used for the separation of the lipid species ...
-
bioRxiv - Microbiology 2024Quote: ... All samples were then vortexed and centrifuged at 10,000 x g for 3 min at 4 ºC and then diluted 2-fold with buffer in conical polypropylene HPLC vials (Phenomenex, Torrance, CA) prior to mass spectrometry analysis.
-
bioRxiv - Neuroscience 2022Quote: Dried metabolites were resuspended in 50% ACN:water and 1/10th was loaded onto a Luna 3 μm NH2 100A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation under HILIC conditions was performed on a Vanquish Flex (Thermo Scientific ...