Labshake search
Citations for Phenomenex :
1 - 50 of 416 citations for 6 Bromo 3 N ethylamino 1 2 4 triazolo 4 3 a pyridine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Systems Biology 2023Quote: ... 4 3 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column ...
-
bioRxiv - Molecular Biology 2019Quote: ... 3 μm (2.1 × 150 mm) column with Security Guard (4 × 2 mm) at 40°C (Phenomenex, Cheshire, UK). The standards and the samples (5 μl injection volume ...
-
bioRxiv - Systems Biology 2021Quote: ... and 4 x 3 mm ID Carbo-H guard (Phenomenex, Torrance, CA). The column was maintained at 50 °C and 1.5 mM H2SO4 was used as the mobile phase at a flow rate of 0.6 mL/min ...
-
bioRxiv - Bioengineering 2023Quote: ... in combination with a Security Guard HPLC Guard Cartridge system Carbo-H 4 x (4 x 3 mm; Phenomenex, Torrance, California, USA) as pre-column was used at 80 °C ...
-
bioRxiv - Microbiology 2024Quote: ... All samples were then vortexed and centrifuged at 10,000 x g for 3 min at 4 ºC and then diluted 2-fold with buffer in conical polypropylene HPLC vials (Phenomenex, Torrance, CA) prior to mass spectrometry analysis.
-
bioRxiv - Biochemistry 2024Quote: ... coupled to a Gemini guard column (Phenomenex, 4 x 3 mm, catalog no.: AJ0-7597). The flow rate for the LC method was 0.5 mL/min ...
-
bioRxiv - Cancer Biology 2023Quote: ... 4 x 2 mm (Phenomenex). The eluents were A ...
-
bioRxiv - Microbiology 2019Quote: ... Luna-NH2 column (3 μm, 150 × 2 mm, Phenomenex) was used flowing at 0.4 mL/min ...
-
bioRxiv - Cancer Biology 2023Quote: ... A Luna C18(2) C8 column (3 μm, 2 mm × 50 mm, Phenomenex) was used ...
-
bioRxiv - Plant Biology 2021Quote: ... Secondary metabolites were separated on an Aqua 3 µm C18 column (150 x 2 mm, 3 µm particle size) equipped with a pre-column filter from Phenomenex. The mobile phase consisted of 1 mM aqueous ammonium acetate (A) ...
-
bioRxiv - Neuroscience 2023Quote: ... The aminopropyl column (Luna 3 µm NH2, 2 × 100 mm, Phenomenex) was used for the chromatographic separation ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 50 × 1 mm; Phenomenex, Torrence, CA) and SenCell (2 mm glassy carbon electrode ...
-
bioRxiv - Cancer Biology 2023Quote: ... using a Synergi HydroRP column (250 x 2; 4 µm, Phenomenex) and 0.1 % of formic acid in water and methanol as mobile phases ...
-
bioRxiv - Neuroscience 2023Quote: ... LC Column (150 × 2 mm, 3 μm particle size; Phenomenex, 00F-4377-B0). Chromatographic separation was achieved using the following conditions ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 150 × 2 mm; Phenomenex, Torrence, CA), guard column (BDS-Hypersil-C18 ...
-
bioRxiv - Neuroscience 2022Quote: ... reconstituted in 100 µl acetonitrile: water (4:1) and filtered through 4 mm x 0.2 µm disks (Phenomenex, Australia) into LC vials ...
-
bioRxiv - Cancer Biology 2022Quote: ... using a Gemini C18 column (250 mm × 3 mm, 3 μm, 110 Å; Phenomenex). Buffer A consisted of 20 mM ammonium formate pH 8.0 and Buffer B of 100% acetonitrile ...
-
bioRxiv - Immunology 2021Quote: ... column Gemini 3 µM C18 HPLC column (150 × 2 mm ID, Phenomenex, Torrance, CA, USA) at 35°C ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μm Fusion-RP 80 A (150 x 2 mm; Phenomenex # 00F-4424-B0) by the methods described below ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μm Fusion-RP 80 A (150 x 2 mm; Phenomenex # 00F-4424-B0) Pump B ...
-
bioRxiv - Genetics 2021Quote: ... equipped with a Gemini C18 (3 mm, 100 mm x 2 mm) analytical column (Phenomenex, USA). An isocratic elution was applied with 80% acetonitrile-20% water and flow rate was set at 200 µL/min ...
-
bioRxiv - Bioengineering 2020Quote: ... 3 μm particle size (Phenomenex, UK). Bexarotene (CAS ...
-
bioRxiv - Cell Biology 2020Quote: ... 3 μm (Phenomenex, Los Angeles, CA). The HPLC-reverse phase column was calibrated with acetyl-CoA (Sigma ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μm C-18 column (Phenomenex) kept at 35°C ...
-
bioRxiv - Immunology 2024Quote: ... 3 μm (Phenomenex, Los Angeles, California). The detailed protocol was described previously (44).
-
bioRxiv - Plant Biology 2021Quote: ... using a reverse-phase column (Synergi 4 mm Hydro-RP 80A, 150 × 2 mm; Phenomenex). A linear gradient of methanol (A) ...
-
bioRxiv - Molecular Biology 2023Quote: ... chromatographic separation was performed on a Luna® NH2 column (100 mm × 2 mm, 3 μm; Phenomenex) maintained at 35°C using mobile phase A [2 mM ammonium acetate in dichloromethane/acetonitrile 7:93 (v/v)] and mobile phase B [2 mM ammonium acetate in water-acetonitrile 50:50 (v/v)] in the following gradient ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Metabolites were separated with a Luna NH2 column (100 mm × 2 mm, 3 μm particle size, Phenomenex). The column was maintained at 15℃ with a solvent flow rate of 0.3 mL min−1 ...
-
bioRxiv - Genomics 2021Quote: ... 4 × 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column ...
-
bioRxiv - Systems Biology 2021Quote: All the samples are analyzed with a nanoPOTS autosampler 6 equipped with a C18 SPE column (100 µm i.d., 4 cm, 300 Å C18 material, Phenomenex) and an LC column (50 µm i.d. ...
-
bioRxiv - Cell Biology 2021Quote: ... 3 μm column (Phenomenex, Torrance, CA, USA). Acetonitrile and 0.1% formic acid were applied for gradient elution with the flow rate of 500 µl/min ...
-
bioRxiv - Cell Biology 2022Quote: ... packed with 3 μm C18 resin (Phenomenex) using a gradient from 7% to 55% buffer B at a flow rate of 500 nL/min ...
-
bioRxiv - Developmental Biology 2022Quote: ... 3 μm particle size (Phenomenex, Torrance, CA)) column packed in-house in Pico-Frit (100 μm X 30 cm ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 µm particle size (Phenomenex, Terrence, USA) at a flow rate of 300 nL/min using a 120 min gradient of 12-45% mobile phase B (acetonitrile + 0.1% formic acid) ...
-
bioRxiv - Plant Biology 2021Quote: ... Separation of metabolites was performed using a Luna C18 column (Phenomenex; 150 × 2 mm, 3 μm particle size). The mobile phase consisted of 97:3 water:methanol with 10 mM tributylamine and 15 mM acetic acid (solvent A ...
-
bioRxiv - Microbiology 2019Quote: ... A 70 μm × 150 mm Luna C18(2) reverse phase column (3 μm; 100-Å pore size; Phenomenex) was packed in-house ...
-
bioRxiv - Physiology 2020Quote: Samples were injected (10 μL) onto a Kinetex C18 column (150 × 3 mm; 2 μm, Phenomenex, Macclesfield, UK) at 40°C using a flow rate of 0.5 mL/min ...
-
bioRxiv - Microbiology 2022Quote: ... The column was a Gemini C18 (50 mm × 2 mm, 100 Å, particle size of 3-μm; Phenomenex). The mobile phases consisted of water (A ...
-
bioRxiv - Cell Biology 2019Quote: ... acidified with formic acid (final concentration 3%) and cleaned by reversed phase solid phase extraction (STRATA-X from Phenomenex, P/N 8B-S100-TAK) following the manufacturer’s instructions ...
-
bioRxiv - Immunology 2022Quote: ... 300 × 7.8 mm i.d., 3 μm, 500 Å; SEC-3000, 300 × 7.8 mm i.d., 3 μm, 290 Å, Phenomenex, Netherlands) two-stage set-up was used ...
-
bioRxiv - Cancer Biology 2023Quote: ... Chromatographic separation of metabolites was achieved by hydrophilic interaction liquid chromatography (HILIC) using a Luna 3 NH2 column (150 mm x 2.1 mm, 3 μm, Phenomenex) in conjunction with a HILIC guard column (Phenomenex ...
-
bioRxiv - Microbiology 2021Quote: ... Samples were analysed on a C18 column (Kinetex 5 μM, C18 100 Å, 250 × 4·6 mm, Phenomenex, Utrecht, The Netherlands) using a gradient of water/methanol with 0·1% formic acid (0–3 min ...
-
bioRxiv - Biochemistry 2020Quote: ... 4 x 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column on an Agilent 1260 Infinity HPLC ...
-
bioRxiv - Systems Biology 2021Quote: ... 4 x 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column ...
-
bioRxiv - Systems Biology 2021Quote: ... 4 x 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column on an Agilent 1260 Infinity HPLC ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 x 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column ...
-
bioRxiv - Molecular Biology 2024Quote: ... 4 x 2.0 mm SecurityGuard (Phenomenex) cartridge as a guard column ...
-
bioRxiv - Systems Biology 2020Quote: ... samples were four-fold diluted with 1% TFA in isopropanol and loaded onto SDB-RPS cartridges (Strata™-X-C, 30 mg/ 3 ml or Strata™-X-C, 200 mg/ 6 ml, Phenomenex Inc.). Before peptide loading ...
-
bioRxiv - Neuroscience 2020Quote: ... this biphasic column was connected to a 100 μm inner diameter-fused silica capillary (Polymicro Technologies) analytical column with a 3 μm pulled tip packed with 10 cm of 3 μm C18 resin (Phenomenex). The entire three-phase column was then laced in line with a 1,200 quaternary HPLC pump (Agilent Technologies ...
-
bioRxiv - Immunology 2020Quote: ... Labelled peptides were solubilized in 20 mM ammonium formate (pH 8.0) and separated on a Gemini C18 column (250 × 3 mm, 3 μm C18 110 Å pore size; Phenomenex). Using a DGP-3600BM pump system equipped with a SRD-3600 degasser (Thermo-Fisher) ...