Labshake search
Citations for Leica :
1 - 50 of 110 citations for beta Tubulin III Rabbit Recombinant mAb since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2024Quote: ... CD56 (mAb NCL-L-CD56-1B6, Leica), Granzyme B (Abcam ab4059) ...
-
bioRxiv - Biochemistry 2023Quote: ... Rabbit mAb (Mouse Preferred; IHC Formulated) (CST, #12202)) was used 1:200 and developed with Bond Polymer Refine Detection (Leica, DS9800).
-
bioRxiv - Evolutionary Biology 2020Quote: ... Hematoxylin Gill III (Surgipath, Leica) was applied to the tissue for 2 minutes ...
-
bioRxiv - Physiology 2022Quote: ... by BOND MAX/III (Leica) with BOND Polymer Refine Detection (ds9800 ...
-
bioRxiv - Cell Biology 2021Quote: ... An automated stainer (Bond III, Leica) was used for immunohistochemistry ...
-
bioRxiv - Immunology 2019Quote: ... and the Bond-III Autostainer (Leica Microsystems), and multiplex immunohistochemistry ...
-
bioRxiv - Cancer Biology 2019Quote: ... and the Bond-III Autostainer (Leica Microsystems) according to a protocol described elsewhere(20 ...
-
bioRxiv - Cell Biology 2021Quote: ... using a dissecting microscope (MZ FL III, Leica) equipped with a camera (DFL420 ...
-
bioRxiv - Physiology 2021Quote: An automated IHC stainer BOND-III (Leica Biosystems) was used ...
-
bioRxiv - Cancer Biology 2019Quote: ... mouse anti-human CD163 mAb (clone, 10D6; Leica Biosystems, Buffalo Grove, IL), rabbit anti-mouse β-catenin pAbs (Proteintech ...
-
Induction of PARP7 Creates a Vulnerability for Growth Inhibition by RBN2397 in Prostate Cancer CellsbioRxiv - Cancer Biology 2023Quote: ... CYCLIN A (1:500, mouse mAb 6E6, Leica Microsystems NCL-CYCLIN A), STAT1α (1:1,000 ...
-
bioRxiv - Cancer Biology 2024Quote: ... on a bond III automated stainer (Leica Biosystems, IL).
-
bioRxiv - Cell Biology 2019Quote: ... Immunohistochemistry was performed using an automated immunostainer (Bond III, Leica). Primary antibodies used for immunohistochemistry are KRT14 (Sigma Aldrich ...
-
bioRxiv - Neuroscience 2021Quote: ... with specific antibodies and an immunostaining system (Bond III, Leica). Images were acquired using a slide scanner (Lamina ...
-
bioRxiv - Cancer Biology 2021Quote: ... was performed using the Bond III auto-stainer (Leica Microsystems). The degree of fluorescence intensity was assessed using MetaMorph Microscopy Automation and Image Analysis Software (Molecular Devices).
-
bioRxiv - Cancer Biology 2020Quote: ... BOND-III fully automated immunohistochemistry stainer (Leica Biosystems, Wetzlar, Germany) carried out the immunostaining ...
-
bioRxiv - Physiology 2021Quote: ... Immunohistochemistry was carried out in a Leica Bond III (Leica Biosystems) automatic stainer ...
-
bioRxiv - Cancer Biology 2023Quote: ... was performed using an automated staining system (Bond III, Leica Biosystems). Semi-quantitative scoring was performed for the intensity of staining of tumor cell membranes (0 = negative ...
-
bioRxiv - Neuroscience 2020Quote: ... MAP2 and GFAP was performed using the Bond III automatic stainer (Leica) using the conditions described (Extended Data Table 1) ...
-
bioRxiv - Genomics 2019Quote: ... followed by immunostaining performed on the Leica Bond III autostainer (Leica Biosystems). Antibodies used included mouse monoclonal anti-human CD3 (DAKO ...
-
bioRxiv - Cancer Biology 2023Quote: ... Immunostaining was performed using an automated BOND-III Autostainer (Leica Microsystems, UK) according to protocols described previously42.
-
bioRxiv - Cancer Biology 2023Quote: ... Immunostaining was performed using the automated BOND-III Autostainer (Leica Microsystems, UK) according to protocols described previously32 ...
-
bioRxiv - Immunology 2023Quote: ... Tissue was deparaffinized then stained with Hematoxylin Gill III (Leica Ca.# 3801542) for two minutes followed by an eosin counterstain (Leica Cat# 3801602) ...
-
bioRxiv - Bioengineering 2021Quote: ... Staining was performed on the automated Leica IHC Bond-III platform (Leica Biosystems).
-
bioRxiv - Immunology 2022Quote: ... slides were placed in Surgipath Hematoxylin Gill III (3801542; Leica Biosystems, Concord, Canada) for 2 min ...
-
bioRxiv - Cancer Biology 2022Quote: ... The slides were then transferred to the BOND-III automated IHC Stainer (Leica) for stepwise incubation with BOND Epitope Retrieval Solution 1 pH 6 (AR9961 ...
-
bioRxiv - Developmental Biology 2022Quote: ... (iii) an inverted laser scanning confocal microscope Leica TCS SP5 II (Leica Microsystems) with a 63x (NA1.3 GLYCEROL ...
-
bioRxiv - Neuroscience 2019Quote: ... 12µm cryosections were stained on a fully automated Leica Bond III (Leica Biosystems, Germany) using the Leica Bond Polymer Refine Detection Kits (DS9800+ DS9390).
-
bioRxiv - Immunology 2021Quote: ... samples were stained using the BOND-III fully automated IHC/ISH stainer (Leica Biosystems) according to the manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2023Quote: ... IHC for P53 detection was performed on a Bond-III (Leica Microsystems, Wetzlar, Germany) using the clone DO-7 monoclonal antibody (GA61661-2 ...
-
bioRxiv - Genetics 2022Quote: ... Stabilized fish are placed onto the stage of the confocal microscope (Leica TCS LSI-III) for image capture ...
-
Role of autophagy in sepsis-induced skeletal muscle dysfunction, whole-body metabolism, and survivalbioRxiv - Cell Biology 2021Quote: ... Ultrathin longitudinal sections (60 nm) were cut with a Reichert-Jung Ultracut III ultramicrotome (Leica Microsystems), mounted on nickel carbon-formvar coated grids ...
-
bioRxiv - Cancer Biology 2022Quote: ... Immunostains were performed in an automatic immunostainer using program ER2 (Bond III, Leica Biosystems, Nussloch, Germany) using the manufactureŕs protocols and detection reagents ...
-
bioRxiv - Cancer Biology 2021Quote: ... The BOND-III Fully Automated IHC staining was detected using the BOND Polymer Refine Detection (Leica, DS9800). Images were acquired with a Revolve Upright and Inverted Microscope System (Echo Laboratories).
-
bioRxiv - Neuroscience 2019Quote: Immunohistochemistry for S1PR1 was performed on an automated stainer (Leica Bond III, Leica Biosystems, Buffalo Grove, IL) using an anti-human S1PR1 rabbit polyclonal antibody (Santa Cruz Biotechnology Inc. ...
-
bioRxiv - Cancer Biology 2020Quote: ... a standardized automated protocol using the Leica Bond Polymer Refining Kit (Leica Bond-III stainer, Leica Biosystems) was performed ...
-
bioRxiv - Cancer Biology 2020Quote: ... a standardized automated protocol using the Leica Bond Polymer Refining Kit (Leica Bond-III stainer, Leica Biosystems) was performed ...
-
bioRxiv - Cancer Biology 2022Quote: ... the following steps were processed in the BOND-III Fully Automated IHC/ISH Staining System (Leica BioSystems). Sections were first deparaffinized and then underwent antigen retrieval by incubating with EDTA-based epitope retrieval solution (BOND Epitope Retrieval Solution 2 ...
-
bioRxiv - Microbiology 2022Quote: ... All staining reactions were performed by automated staining using a BOND III autostainer (Leica Biosystems, Wetzlar, Germany). For immunohistochemistry ...
-
bioRxiv - Cell Biology 2022Quote: ... 15 minutes of Protease III (ACD) at 40°C using the Bond RX auto-stainer (Leica Biosystems), and 1:750 dilution of TSA-Cyanine 5 Plus (AKOYA ...
-
bioRxiv - Molecular Biology 2023Quote: ... Zi-1 = 75.61μm) of pancreatic beta cells using the microscope’s TXR filter and a 40X objective (Leica HCX APO L U-V-I 0.80 W), at 20 msec exposures ...
-
bioRxiv - Cancer Biology 2023Quote: IHC staining for FOXM1 was performed using Bond III IHC auto-stainer for full Automated Immunohistochemistry (Leica Biosystems). Antigen was unmasked with Tris-EDTA pH 9 (Bond Epitope Retrieval Solution 2 ...
-
bioRxiv - Cancer Biology 2021Quote: ... staining were performed using the Leica BOND-III automated staining system and the Leica refine detection kit as per manufacturer’s instructions (Leica). Trypsin-based antigen retrieval was used for F4/80 staining ...
-
bioRxiv - Neuroscience 2019Quote: ... CD3 and B220 immunostaining were performed according to standard procedure using an Automated IHC Stainer (Bond-III, Leica Biosystems). Deparaffinized and rehydrated sections were incubated with CD3 (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2023Quote: ... We mounted 5μm sections from the TMA block on glass slides and performed immunohistochemical staining via a Bond III (Leica) automated immunostaining platform with optimal dilutions of each primary antibody determined by an initial serial dilution to minimize background while retaining foreground staining in sections with pathology ...
-
bioRxiv - Neuroscience 2023Quote: ... immunohistochemistry was performed using a Leica Bond III Fully Automated IHC and ISH Staining System (Leica Biosystems, Wetzlar, Germany). The sections were immunostained with mouse monoclonal antibody against paired helical filament tau (AT8 ...
-
bioRxiv - Developmental Biology 2021Quote: ... rabbit anti-p53 (Leica, CM5P), mouse anti-γH2AX ...
-
bioRxiv - Plant Biology 2020Quote: Primary transformants were identified using the seed-specific RFP reporter under a Leica MZ-FL III stereomicroscope (Leica Camera AG). Genotyping of CRISPR/Cas9-based mutations and T-DNA insertions were performed using KAPA-Taq (Sigma-Aldrich ...
-
bioRxiv - Neuroscience 2023Quote: ... Digital images of DAB-stained sections were acquired using a whole slide scanner (3D-Histech Pannoramic 250 Flash III, Sysmex Deutschland GmbH, Norderstedt, Germany or Aperio Versa 8, Leica Biosystems Nussloch GmbH ...
-
bioRxiv - Cancer Biology 2022Quote: ... IHC staining for Ki67 and MGP antibodies was performed using Bond III IHC autostainer for full Automated Immunohistochemistry (Leica biosystems). Antigen was unmasked with Tris-EDTA pH 9 (Bond Epitop Retrival Solution 2 Leica ...