Labshake search
Citations for Leica :
1 - 50 of 947 citations for 7 Chloro N 3 chloro 4 fluorophenyl 6 nitro 4 quinazolinamine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Developmental Biology 2019Quote: ... Cell counts were done on serial sections immunostained for GnRH-1 at E13.5 (n=3) and E15.0 (n=4) and visualized under bright field (immunoperoxidase) or epi-fluorescence illumination (20×; Leica DM4000 B LED), according to their anatomical location [i.e. ...
-
bioRxiv - Developmental Biology 2020Quote: ... Image stacks were obtained every 3-4 minutes for 6-8 hours using a LSM880 (Leica) with an environmental chamber (37°C with 5% CO2) ...
-
bioRxiv - Cancer Biology 2019Quote: ... 4 and 7 days-post injection using a fluorescent stereoscope (Leica M205FA). Transplanted larvae were kept in individual wells of a 6 well-plate to allow individual tracking of melanoma progression ...
-
bioRxiv - Cell Biology 2024Quote: ... sectioned to 3-4 μm thickness (Leica RM2255, Germany), and stained with hematoxylin and eosin (H&E) ...
-
bioRxiv - Physiology 2023Quote: ... Sections of 4-6 µm were produced using a microtome (Leica). Deparaffination and rehydration was performed using standard procedure by incubating in Xylene (2 x 5 min) ...
-
bioRxiv - Neuroscience 2019Quote: ... unfixed C57BL/6 mouse brains (N = 3) were embedded in tissue freezing medium (Leica Biosystems, Richmond, UK), frozen on a dry ice ethanol bath ...
-
bioRxiv - Neuroscience 2019Quote: ... 3 and 4 are compositions of more fields automatically generated by Leica LAS X software or NIS elements software ...
-
bioRxiv - Pathology 2021Quote: ... Slides were then treated with 3-4% hydrogen peroxide (Leica Biosystems RE7101) for 10 minutes ...
-
bioRxiv - Cell Biology 2022Quote: ... or for 4–6 s at 4°C and ~ 86% and plunge frozen using a Leica EM GP (Leica Microsystems Inc, Buffalo Grove, IL). The samples were imaged in an FEI Titan Krios electron microscope operated at 300 kV with a K2 Summit camera and energy filter (Gatan ...
-
bioRxiv - Cell Biology 2023Quote: ... specimens were sputter coated with 3-4 nm of platinum (Leica EM ACE600). Samples were imaged using a Helios Nanolab 660 DualBeam Microscope (FEI).
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... About 3-4 µm sections were prepared using an automated microtome (RM2255, Leica Biosystems, Germany) and the sections were stained with hematoxylin and eosin (H&E ...
-
bioRxiv - Microbiology 2024Quote: ... containing 4‘,6-diamidino-2-phenylindole (DAPI) and imaged as midsections by confocal laser scanning microscopy (Leica SP8 ...
-
bioRxiv - Neuroscience 2021Quote: ... Cells were finally mounted in 4’,6-diamidino-2-phenylindole (DAPI) and examined using fluorescence microscope (Leica DMi8). The first antibodies include rabbit anti-Iba1 (Wako) ...
-
bioRxiv - Neuroscience 2022Quote: ... Cells were finally mounted in 4’,6-diamidino-2-phenylindole (DAPI) and examined using fluorescence microscope (Leica DMi8). Embryonic and postnatal ventral midbrain tissues were fixed with 4% paraformaldehyde and dehydrated with 30% sucrose overnight ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were finally mounted in 4’,6-diamidino-2-phenylindole (DAPI) and examined using fluorescence microscope (Leica DMi8). The first antibodies include rabbit mouse anti-sarcomeric α-actinin (SAA ...
-
bioRxiv - Pathology 2022Quote: ... Cells were finally mounted in 4’,6-diamidino-2-phenylindole (DAPI) and examined using fluorescence microscope (Leica DMi8). The first antibodies are listed in Supplementary Table S2.
-
bioRxiv - Neuroscience 2023Quote: ... Cells were finally counterstained with 4’,6-diamidino-2-phenylindole (DAPI) and examined using fluorescence microscope (Leica DMi8).
-
bioRxiv - Molecular Biology 2022Quote: ... temporal bones were immersed in 30% sucrose in PBS and stored at 4°C for 7 days before being cut into 14-16 micron thick sections on a cryostat (Leica CM3050). For each species ...
-
bioRxiv - Developmental Biology 2019Quote: ... Serial sections of 4–6 µm thickness were cut using a Leica RM2255 rotary microtome (Leica Microsystems GmbH, Germany) with disposable blades ...
-
bioRxiv - Biochemistry 2020Quote: ... and allowed to set O/N at 4 °C before being imaged using a SP8 white-laser confocal microscope (Leica Microsystems). Filters were adjusted specifically for each stain to visualize nuclei (Hoechst ...
-
bioRxiv - Neuroscience 2021Quote: ... brains of perfused mice (n=4 per group) were serially cut into 35 μm-thick coronal sections using cryostat (Leica, Germany). Sections were permeabilized in PBS containing 0.3% Triton X-100 for 30 min ...
-
bioRxiv - Cell Biology 2024Quote: ... The tissues in paraffin blocks were subjected to sectioning (3-4 μM) by rotary type of microtome (Leica RM2255 Rotary Microtome ...
-
bioRxiv - Neuroscience 2022Quote: ... Frozen brains were cut to either 10 μm slices for immunofluorescence staining or 4-6 μm for STORM (CM1950, Leica) to produce coronal brain sections.
-
bioRxiv - Cell Biology 2023Quote: ... 30% sucrose in PBS (2:1 v/v) over-night (O/N) at 4°C with gentle shaking and frozen in OCT (Leica Surgipath, FSC22), using plastic molds (Leica Surgipath ...
-
bioRxiv - Microbiology 2020Quote: Total cell counts were determined by staining with 4’,6-diamidino-2-phenylindole (DAPI) and visualizing on a Leica DMRX epifluorescence microscope (Leica, Germany). The number of FLA-YM stained cells were determined by enumerating cells which had a positive DAPI and FLA-YM signal (excitation at 405 nm and 488 nm wavelengths ...
-
bioRxiv - Molecular Biology 2022Quote: ... Green siliques were harvested 12 d after flowering from 4-6 week old plants and opened using fine needles under a dissecting microscope (Leica MZ9.5, Germany). Images of opened siliques were captured using a Leica DFC290 (Germany ...
-
bioRxiv - Cell Biology 2022Quote: ... Dried samples were then rotary shadowed with 2 nm of platinum and 4-6 nm of carbon using the ACE600 (Leica Microsystems, Germany). Areas of interest from the resulting platinum replicas were separated from glass with 5% hydrofluoric acid and deposited on carbon-coated EM grids (200 mesh formvar/carbon ...
-
bioRxiv - Cell Biology 2022Quote: ... Dried samples were then rotary shadowed with 2 nm of platinum (sputtering) and 4-6 nm of carbon (carbon thread evaporation) using an ACE600 metal coater (Leica Microsystems, Germany). The resultant platinum replica was floated off the glass with hydrofluoric acid (5%) ...
-
bioRxiv - Neuroscience 2023Quote: ... Images of cultured ependymocytes co-treated with Sir-Actin and calcein AM were captured at 10-s intervals for 12 minutes while that of co-treated with Sir-Actin and fluo-4 AM were captured at 10-s intervals for 6 minutes using confocal scanning microscope (DMi8, Leica, Wetzlar, Germany). The intensity of F-actin area from all Sir-Actin positive cells in a field of recording were included in the statistics ...
-
bioRxiv - Neuroscience 2023Quote: ... The fluorescence signals of Fluo-4 were monitored at 10-s intervals for 6 minutes by confocal scanning microscope (DMi8, Leica, Wetzlar, Germany). As previously described 46 ...
-
bioRxiv - Microbiology 2024Quote: ... containing 4‘,6-diamidino-2-phenylindole (DAPI) and imaged as midsections by confocal laser scanning microscopy (Leica SP8: Leica Microsystems, Wetzlar, Germany). To prevent cross talk between the channels for the different fluorochromes ...
-
bioRxiv - Cell Biology 2023Quote: ... Dried samples were then rotary shadowed with 2 nm of platinum (sputtering) and 4-6 nm of carbon (carbon thread evaporation) using an ACE600 metal coater (Leica Microsystems, Germany). The resultant platinum replica was floated off the glass with hydrofluoric acid (5%) ...
-
bioRxiv - Neuroscience 2020Quote: ... Brains were embedded in agar (3-4%) and coronal sections (50 µm) were cut on a vibrating microtome (Leica VT1000S) and collected in a 1 in 4 series ...
-
bioRxiv - Cell Biology 2019Quote: PFA-fixed adult mouse (3-4 month) brains were cut into 1-mm-thick sections using a vibratome (Leica, VT1200S) [11 ...
-
bioRxiv - Cell Biology 2021Quote: ... Dried samples were then coated with 3 nm platinum and 4 nm carbon using an ACE600 coating device (Leica Microsystems). The sample grids were imaged using a JEOL JEM2800 scanning/transmission electron microscope at 200 kV.
-
bioRxiv - Cell Biology 2020Quote: ... Bright field images of beating cilia were captured at 160 frames per sec over 4 seconds (3-5 videos per insert, Leica Spinning disc confocal with 40x water objective) ...
-
bioRxiv - Plant Biology 2022Quote: ... The samples were then coated with 3 nm platinum and 4 nm carbon using the ACE600 coating device (Leica Microsystems).
-
bioRxiv - Molecular Biology 2020Quote: Frozen coronal ovine hypothalamic blocks (n=4 per group) for in-situ hybridization were cut into 16µm sections using a cryostat (CM3050s Leica Microsystems, Ltd., Milton Keynes, UK), and thaw mounted onto poly-l-lysine coated slides (VWR International ...
-
bioRxiv - Pathology 2022Quote: ... Pictures of 4-6 different fields per sample were taken under a Leica DM5000 B microscope equipped with a digital CCD (Leica Camera, Wetzlar, Germany).
-
bioRxiv - Biophysics 2023Quote: ... at 40 °C and for 7 min in 3 % lead citrate (Ultrostain II, Leica) at 20 °C ...
-
bioRxiv - Cell Biology 2021Quote: ... whereas samples for STEM were attached to a sticky Post-It-Note (as described in (31)) and coated with 3 nm platinum and 4 nm carbon using an ACE600 coating device (Leica Microsystems). The STEM samples were then washed with Buffered Oxide Etchant (diluted 6:1 with surfactant ...
-
bioRxiv - Cell Biology 2019Quote: ... for 2 days at 4 °C and then transferred to 70% alcohol for 3-5 days before processed by using 4-hour tissue processing setting with Leica ASP6025 (Leica Biosystems). Placentas were embedded in paraffin (HistoCore Arcadia H and Arcadia C ...
-
bioRxiv - Cell Biology 2024Quote: ... The tissues in paraffin blocks were subjected to sectioning (3-4 μM) by rotary type of microtome (Leica RM2255 Rotary Microtome, Leica Biosystems). The tissue sections were fixed in a glass slide and stained with hematoxylin and eosin (H&E ...
-
bioRxiv - Neuroscience 2021Quote: ... post-fixed in 4% PFA overnight at 4°C and afterwards cut with a vibratome (Leica Microsystems, Wetzlar Germany) in 100 μM thick sequential sagittal slices ...
-
bioRxiv - Neuroscience 2023Quote: ... post-fixed in 4% PFA overnight at 4 °C and 100um thick coronal vibratome sections were made (Leica VT1000S). Images of both ipsilateral (injected ...
-
bioRxiv - Neuroscience 2023Quote: ... Brains were postfixed overnight in 4% PFA at 4°C before 50μm coronal brain sections were cut using a vibratome (VT1200S, Leica). Slices were blocked (TBS with 0.5% Triton X-100 and 10% donkey serum ...
-
bioRxiv - Cell Biology 2021Quote: ... stained with DAPI (4’,6-diamidino-2-phenylindole) for visualisation of the nuclei and analysed by confocal microscopy using an inverted microscope (Leica DMI6000, objective lens 100×).
-
bioRxiv - Neuroscience 2020Quote: ... All mouse brain tissue specimens were fixed by immersion in 4% PFA overnight at 4 °C and sectioned at 50 μm using a vibratome (Leica).
-
bioRxiv - Neuroscience 2022Quote: ... Brains were post-fixed overnight in 4% PFA at 4 °C and sectioned at 40 μm using a vibratome (VT1000S, Leica) except for experiments involving the RNAscope kit (ACD Bio.) ...
-
bioRxiv - Neuroscience 2022Quote: ... Brains were then post-fixed for overnight in 4% paraformaldehyde at 4 and sectioned into 40 µm sagittal slices using a vibratome (VT1000S, Leica). Brain sections were incubated in blocking solution (0.2% Triton X-100 in PBS with 5% normal goat serum ...