Labshake search
Citations for Leica :
1 - 50 of 733 citations for 7α 12α Dihydroxycholest 4 en 3 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2024Quote: ... sectioned to 3-4 μm thickness (Leica RM2255, Germany), and stained with hematoxylin and eosin (H&E) ...
-
bioRxiv - Cell Biology 2024Quote: ... and cell monolayers were sectioned ‘en face’ at 70 nm thickness using a Reichart Ultracut S ultramicrotome (Leica) and a diamond knife (Diatome) ...
-
bioRxiv - Neuroscience 2019Quote: ... 3 and 4 are compositions of more fields automatically generated by Leica LAS X software or NIS elements software ...
-
bioRxiv - Pathology 2021Quote: ... Slides were then treated with 3-4% hydrogen peroxide (Leica Biosystems RE7101) for 10 minutes ...
-
bioRxiv - Developmental Biology 2020Quote: En face STED images of mouse cephalic explants were taken with a Leica SP8 TCS STED microscope (Leica Microsystems) equipped with a pulsed white-light excitation laser (WLL ...
-
bioRxiv - Cell Biology 2023Quote: ... specimens were sputter coated with 3-4 nm of platinum (Leica EM ACE600). Samples were imaged using a Helios Nanolab 660 DualBeam Microscope (FEI).
-
bioRxiv - Microbiology 2019Quote: Images of infected tissues were acquired en face with an upright DM6000FS Leica confocal microscope (Leica microsystems Gmbh, Wetzlar, Germany) coupled with a Yokogawa CSU-X1 Spinning Disk (Yokogawa ...
-
bioRxiv - Developmental Biology 2023Quote: ... was injected into the cytoplasm of wild-type embryos at one-cell stage using an MPPI-3 microinjector (ASI) under a stereomicroscope (S9E, Leica). Injected embryos were incubated in the embryo medium (10% Hank’s with full strength calcium and magnesium ...
-
bioRxiv - Neuroscience 2020Quote: ... Mice were anesthetized with a mixture of oxygen (1 L/min) and isoflurane 3% (Baxter AG, Vienna, Austria) and placed in a stereotactic frame (Angle One; Leica, Germany). The skin was shaved ...
-
bioRxiv - Neuroscience 2021Quote: ... Mice were anesthetized with a mixture of oxygen (1L/min) and isoflurane 3% (Baxter AG, Vienna, Austria) and placed in a stereotactic frame (Angle One; Leica, Germany). The skin was shaved ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... About 3-4 µm sections were prepared using an automated microtome (RM2255, Leica Biosystems, Germany) and the sections were stained with hematoxylin and eosin (H&E ...
-
bioRxiv - Developmental Biology 2020Quote: ... Image stacks were obtained every 3-4 minutes for 6-8 hours using a LSM880 (Leica) with an environmental chamber (37°C with 5% CO2) ...
-
bioRxiv - Microbiology 2019Quote: ... and imaged en face using a Yokogawa CSU-X1 Spinning Disk (Yokogawa, Tokyo, Japan) coupled with a DMI6000B Leica microscope (Leica microsystems Gmbh, Wetzlar, Germany). Acquisitions were made with MetaMorph 7 software ...
-
bioRxiv - Neuroscience 2023Quote: ... Under one fluorescence microscope(Leica dm6000B ...
-
bioRxiv - Cell Biology 2024Quote: ... The tissues in paraffin blocks were subjected to sectioning (3-4 μM) by rotary type of microtome (Leica RM2255 Rotary Microtome ...
-
bioRxiv - Molecular Biology 2020Quote: ... the individual primordial oocyte was collected from 2-3 adjacent tissue sections to ensure that one full cell was included (Leica Microsystems, Buffalo Grove, IL, USA).
-
bioRxiv - Neuroscience 2022Quote: ... one with 488 nm (Leica, Germany) and two additional lasers with 532 nm and 635 nm wavelengths (OneFive ...
-
bioRxiv - Immunology 2022Quote: ... 3′-3-diaminobenzidine (DAB) substrate (Leica Microsystems) was used as a chromogen followed by hematoxylin counterstain ...
-
bioRxiv - Neuroscience 2020Quote: ... Brains were embedded in agar (3-4%) and coronal sections (50 µm) were cut on a vibrating microtome (Leica VT1000S) and collected in a 1 in 4 series ...
-
bioRxiv - Cell Biology 2019Quote: PFA-fixed adult mouse (3-4 month) brains were cut into 1-mm-thick sections using a vibratome (Leica, VT1200S) [11 ...
-
bioRxiv - Cell Biology 2021Quote: ... Dried samples were then coated with 3 nm platinum and 4 nm carbon using an ACE600 coating device (Leica Microsystems). The sample grids were imaged using a JEOL JEM2800 scanning/transmission electron microscope at 200 kV.
-
bioRxiv - Cell Biology 2020Quote: ... Bright field images of beating cilia were captured at 160 frames per sec over 4 seconds (3-5 videos per insert, Leica Spinning disc confocal with 40x water objective) ...
-
bioRxiv - Plant Biology 2022Quote: ... The samples were then coated with 3 nm platinum and 4 nm carbon using the ACE600 coating device (Leica Microsystems).
-
bioRxiv - Cell Biology 2021Quote: ... whereas samples for STEM were attached to a sticky Post-It-Note (as described in (31)) and coated with 3 nm platinum and 4 nm carbon using an ACE600 coating device (Leica Microsystems). The STEM samples were then washed with Buffered Oxide Etchant (diluted 6:1 with surfactant ...
-
bioRxiv - Cell Biology 2019Quote: ... for 2 days at 4 °C and then transferred to 70% alcohol for 3-5 days before processed by using 4-hour tissue processing setting with Leica ASP6025 (Leica Biosystems). Placentas were embedded in paraffin (HistoCore Arcadia H and Arcadia C ...
-
bioRxiv - Cell Biology 2024Quote: ... The tissues in paraffin blocks were subjected to sectioning (3-4 μM) by rotary type of microtome (Leica RM2255 Rotary Microtome, Leica Biosystems). The tissue sections were fixed in a glass slide and stained with hematoxylin and eosin (H&E ...
-
bioRxiv - Developmental Biology 2022Quote: ... one by one taken out of the medium and positioned along the anteroposterior axis under a stereo microscope (Leica MZ16 FA) in a 1.5% agarose gel (Sigma Aldrich IX-A ...
-
bioRxiv - Neuroscience 2020Quote: ... Slices were prepared in oxygenated (95% O2 / 5% CO2) dissection artificial cerebrospinal fluid (ACSF) at low temperature (3-4°C) using vibroslicer (Leica, VT 1200S). After preparation slices were recovered in a resting chamber (Harvard apparatus ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: ... blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems, Germany). Cryo-EM data were collected on a Talos Arctica transmission electron microscope operated at 200 kV acceleration voltage using EPU automated data collection software (ThermoFisher Scientific ...
-
bioRxiv - Developmental Biology 2019Quote: ... Cell counts were done on serial sections immunostained for GnRH-1 at E13.5 (n=3) and E15.0 (n=4) and visualized under bright field (immunoperoxidase) or epi-fluorescence illumination (20×; Leica DM4000 B LED), according to their anatomical location [i.e. ...
-
bioRxiv - Microbiology 2021Quote: ... and one frozen in tissue freezing medium (Leica, Australia) for cryosectioning ...
-
bioRxiv - Immunology 2019Quote: Pools of 20 larvae were collected at 3- and 4-day post infection (dpi) and imaged by using the Leica MZ16FA Fluorescence Stereo Microscope (Leica Microsystems, Wetzlar Germany) equipped with the DFC420C color camera (Leica Microsystems) ...
-
bioRxiv - Developmental Biology 2020Quote: Imaging of embryos and tissues was performed using a Leica MZ 16F dissecting microscope equipped with a Leica DFC420 C digital camera supported by the Leica Application Suite software package (LAS, version 3 or 4; Leica Microsystems, Germany/Switzerland), and Leica EL6000 fluorescence light source.
-
bioRxiv - Bioengineering 2022Quote: ... 3′-diaminobenzidine (Leica).
-
bioRxiv - Neuroscience 2022Quote: ... An Impact One Stereotaxic Impactor (Leica Biosystems, Buffalo Grove, IL) attached to a steel impactor with a 3-mm flat tip with rounded edges (Cat# 2520-3S ...
-
bioRxiv - Neuroscience 2022Quote: ... an Impact One Stereotaxic Impactor (Leica Biosystems; Buffalo Grove, IL) was used to produce the linear r-mTBI concussive impacts ...
-
bioRxiv - Neuroscience 2023Quote: ... An Impact One Stereotaxic Impactor (Leica Biosystems, Deer Park, IL) was used to produce concussive models of repetitive mild TBI (r-mTBI ...
-
bioRxiv - Neuroscience 2023Quote: ... Mice were oriented in the stereotaxic frame (Leica Angle One) and ear bars were placed to level and secure the head ...
-
bioRxiv - Neuroscience 2023Quote: ... one side was exposed using an ultra-microtome (UC7, Leica), then flipped to be remounted to a metal pin with conductive silver epoxy (CircuitWorks ...
-
bioRxiv - Neuroscience 2022Quote: ... One sample brain was sectioned using a cryostat (Leica 3050 S) and imaged with an epifluorescence microscope (Zeiss Axio Imager 2).
-
bioRxiv - Cell Biology 2023Quote: ... One hundred µm sections were made using a vibratome (Leica #VT1200) as described here23 ...
-
bioRxiv - Neuroscience 2020Quote: ... The animals were placed in a stereotactic frame (Angle One; Leica, Germany) and bilateral injections were performed in the SC (ML ± 0.8 mm ...
-
bioRxiv - Neuroscience 2023Quote: ... Under one fluorescence microscope(Leica dm6000B, Leica Microsystems Inc., Buffalo Grove, IL) or Zeiss LSM-710 inverted confocal microscope ...
-
bioRxiv - Biochemistry 2022Quote: ... Pelco Easiglow) and vitrified (3 μL sample, 3 s blot time) using an automatic plunge freezer (Leica). EndoX-TSEN•CLP1 was frozen on R1.2/1.3 Cu 300 mesh grids (Quantifoil ...
-
bioRxiv - Neuroscience 2021Quote: ... adult mice (P50-60) were placed on a stereotaxic frame (Angle One; Leica, Germany). Bilateral craniotomy (1 mm in diameter ...
-
bioRxiv - Cell Biology 2021Quote: ... Micro 3 - a DMi8 microscope (Leica Microsystems) with a high-contrast Plan Apochromat 63×/1.30 Glyc CORR CS objective (Leica Microsystems) ...
-
bioRxiv - Neuroscience 2023Quote: ... and 3% lead citrate (Ultrostain 2, Leica).
-
bioRxiv - Neuroscience 2021Quote: ... CCI injuries were produced using an electromagnetic impactor (Impact One, Leica Biosystems, Buffalo Grove, IL). The contact velocity was set at 3.5 m/s with a cortical impact depth of 1.0 mm ...
-
bioRxiv - Neuroscience 2021Quote: The CCI procedure was carried out using a Leica Impact One device (Leica Microsystems Inc). Anesthetic levels were induced with 4% isoflurane gas mixed in 100% oxygen and the maintained under 2% isoflurane for the rest of the procedure ...
-
bioRxiv - Neuroscience 2020Quote: ... TBI was performed with a CCI device (Impact One Stereotaxic Impactor for CCI, Leica Microsystems) equipped with a metal piston using the following parameters ...