Labshake search
Citations for Molecular Devices :
1 - 50 of 918 citations for 8 10 Heneicosadiynoic acid since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2023Quote: ... filtered at 8 kHz and digitized at 10 kHz using a Digidata 1550A digitizer (Molecular Devices). Neurons were held at -60 mV ...
-
bioRxiv - Cell Biology 2020Quote: ... BODIPY-dodecanoic acid fluorescent fatty acid analog was added (QBT™ Fatty Acid Uptake Assay Kit, Molecular Devices) and the plate was immediately transferred to a fluorescence microplate reader for kinetic reading (every 20 seconds for 30-60 minutes ...
-
bioRxiv - Neuroscience 2022Quote: ... and pClamp 8 (Molecular Devices), and data were filtered at 1 kHz and digitized at 5 kHz ...
-
bioRxiv - Cancer Biology 2020Quote: ... Stain was collected using 10% acetic acid and quantified in a spectrophotometer at 590 nm (SpectraMax ID3, Molecular Devices). The average stain quantification was generated from the water control group and each experimental value was divided by this average to produce a normalized fold change value ...
-
bioRxiv - Cell Biology 2019Quote: The hiPSC-CMs were plated on 10 mm glass coverslips at 1.0 × 104/cm2 and APs were recorded 8-10 days later using the perforated patch-clamp technique and an Axopatch 200B amplifier (Molecular Devices). Single cells with spontaneous contractions (indicating the viable state of the cells ...
-
bioRxiv - Neuroscience 2020Quote: ... and were digitized off-line at 10 kHz (low-pass filtered at 2 kHz with an 8-pole Bessel filter) using pCLAMP9 software (Molecular Devices).
-
bioRxiv - Biophysics 2020Quote: ... Traces were filtered by low-pass Bessel filter at 10 Hz for analyses performed with Origin Pro 8 (OriginLab) and Clampfit software (Molecular devices).
-
bioRxiv - Biophysics 2020Quote: ... Currents were filtered at 10 kHz (−3 dB cutoff, 8-pole Bessel) with an Axopatch 200B amplifier (Molecular Devices, Sunnyvale, USA). For analogue-digital conversion an InstruTECH ITC-18 digitizer (HEKA Elektronik Dr ...
-
bioRxiv - Cancer Biology 2020Quote: ... Destaining for quantification was performed using 10% acetic acid and absorbance was read at 590 nm using a spectrophotometer (SpectraMax iD3, Molecular Devices). An average value of non-targeting vehicle was generated ...
-
bioRxiv - Neuroscience 2019Quote: ... displayed using pClamp 8 software (Molecular Devices).
-
bioRxiv - Neuroscience 2021Quote: ... synaptic currents were filtered at 2 kHz and digitized at 10 kHz (amplifier in-built 8-pole low-pass Bessel filter and Molecular Devices Digidata 1322A, respectively). Recordings used for analysis were post-hoc filtered at 1 kHz.
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... controlled by pCLAMP software (Molecular Devices, version 8).
-
Audiovisual stimuli enhance narrowband gamma activity along the mouse thalamocortical visual circuitbioRxiv - Neuroscience 2023Quote: ... and visualized with the pClamp 8 software (Molecular Devices). In both cortical and thalamic recordings ...
-
bioRxiv - Physiology 2019Quote: ... under the control of pClamp acquisition software (version 8, Molecular Devices). Cells were super-fused continuously with an external solution containing (in mM) ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Data was recorded using pCLAMP 8 data acquisition software (Molecular Devices) and analysed using Clampfit software of pCLAMP 11.0.3 (Axon Instruments) ...
-
bioRxiv - Neuroscience 2022Quote: ... and EPSP amplitude were performed with pCLAMP 8 software (Molecular Devices). Before measurement of EPSPs ...
-
bioRxiv - Neuroscience 2023Quote: ... Master-8 (A.M.P.I.) and pClamp 10.2 software (Molecular Devices, Axon Instruments) controlled the photostimulation output.
-
bioRxiv - Neuroscience 2023Quote: ... Signals were digitized at 8 kHz using a Digidata 1440A (Molecular Devices), and filtered at 4 kHz ...
-
bioRxiv - Biophysics 2020Quote: Clampfit 10 (pCLAMP 10, Molecular Devices), Origin 9.1 (OriginLab Corp. ...
-
bioRxiv - Biophysics 2020Quote: ... Clampex 10 (pCLAMP 10, Molecular Devices) was used to control voltage protocols and for data acquisition.
-
bioRxiv - Neuroscience 2022Quote: ... and sampled at 30 kHz (Axoscope 8; Axon Instruments /Molecular Devices, Burlingame, CA). These grease gap recordings of PAD on sensory afferents reflect only the response of the largest diameter axons in the dorsal root ...
-
bioRxiv - Neuroscience 2021Quote: ... and sampled at 30 kHz (Axoscope 8; Axon Instruments/Molecular Devices, Burlingame, CA).
-
bioRxiv - Neuroscience 2022Quote: ... and sampled at 30 kHz (Axoscope 8; Axon Instruments/Molecular Devices, Burlingame, CA).
-
bioRxiv - Neuroscience 2024Quote: ... and sampled at 30 kHz (Axoscope 8; Axon Instruments/Molecular Devices, Burlingame, CA). The light used for exciting V3 neurons was from a 447 nm D442001FX laser (Laserglow Technologies ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Data were analyzed and plotted using the Clampfit 8 (Molecular Devices, Sunnyvale, CA, USA) and Origin 2022 software (OriginLab Corporation ...
-
bioRxiv - Neuroscience 2023Quote: ... Recordings of FluoAM-8 fluorescence were performed using FlexStation I plate reader (Molecular Devices) with an excitation wavelength of 485 nm and detection of emission at a wavelength of 538 nm over a total period of 120 seconds per well ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Quantification of data was done on GraphPad Prism 8 was or ClampFit 10.7 (Molecular Devices) as indicated ...
-
bioRxiv - Neuroscience 2023Quote: ... using Clampex 10 softwarMe (pClamp 10, Molecular Devices, San Jose, USA). For evoked recordings ...
-
bioRxiv - Cell Biology 2020Quote: ... filtered at 8 kHz and digitized at 20 kHz using a Digidata 1550A digitizer (Molecular Devices). Data were acquired and stored using Clampfit 10.4 software (HEKA Electronics ...
-
bioRxiv - Neuroscience 2022Quote: ... filtered at 8 kHz and digitized at 20 kHz using a Digidata 1550A digitizer (Molecular Devices).
-
bioRxiv - Neuroscience 2022Quote: ... filtered at 8 kHz and digitized at 20 kHz using a Digidata 1550A digitizer (Molecular Devices). The following protocol was used during the IV curve recordings ...
-
bioRxiv - Neuroscience 2021Quote: ... filtered at 8 kHz and digitized at 20 kHz using a Digidata 1440A digitizer (Molecular Devices). Light was delivered using a Lumencor SpecraX light engine ...
-
bioRxiv - Neuroscience 2023Quote: ... filtered at 8 kHz and digitized at 20 kHz using a Digidata 1550A digitizer (Molecular Devices). Extracellular Tyrode solution ...
-
bioRxiv - Neuroscience 2023Quote: ... digitized at 10 kHz using Digidata 1550A and pClamp 10 (Molecular Devices). Recordings were low pass filtered at 4 kHz ...
-
bioRxiv - Neuroscience 2021Quote: ... pCLAMP 10 (Molecular Devices), Clampfit ...
-
bioRxiv - Neuroscience 2020Quote: Clampfit 10 (Molecular Devices), Prism (Graphpad) ...
-
bioRxiv - Neuroscience 2019Quote: Clampfit 10 (Molecular Devices) and GraphPad Prism 7 (La Jolla ...
-
bioRxiv - Neuroscience 2020Quote: ... PClamp 10 (Molecular Devices) and Matlab (MathWorks ...
-
bioRxiv - Cell Biology 2021Quote: ... Clampfit 10 (Molecular Devices), and SigmaPlot 12 were used to analyze data ...
-
bioRxiv - Cell Biology 2021Quote: ... Clampfit 10 (Molecular Devices), and SigmaPlot 12 were used to analyze data.
-
bioRxiv - Neuroscience 2022Quote: ... pCLAMP 10 (Molecular Devices), Clampfit ...
-
bioRxiv - Neuroscience 2020Quote: Clampfit 10 (Molecular Devices), minianalysis (Synaptosoft) ...
-
bioRxiv - Neuroscience 2020Quote: ... pCLAMP 10 (Molecular Devices), Clampfit ...
-
bioRxiv - Neuroscience 2020Quote: ... pCLAMP 10 (Molecular Devices), Clampfit ...
-
bioRxiv - Neuroscience 2019Quote: ... pClamp 10 (Molecular Devices) was used to acquire and analyze data ...
-
bioRxiv - Neuroscience 2022Quote: ... pCLAMP 10 (Molecular Devices). Data and results obtained from the clamps were indistinguishable.
-
bioRxiv - Physiology 2023Quote: ... Clampfit 10 (Molecular Devices), Excel (Microsoft Co) ...
-
bioRxiv - Neuroscience 2023Quote: ... pCLAMP 10 (Molecular Devices), Clampfit ...
-
bioRxiv - Cell Biology 2021Quote: ... filtered at 2 kHz with an 8-pole Bessel filter and analyzed with Clampfit 10.7 (Molecular Devices) and Origin 8 Pro (Origin Lab ...
-
bioRxiv - Neuroscience 2019Quote: ... Data were low-pass filtered at 10 kHz and acquired at 10 kHz using Multiclamp 700B (Axon Instruments) and pClamp 10 (Molecular Devices). Purkinje cells for recording were selected at random ...