Labshake search
Citations for Electron Microscopy Sciences :
1 - 50 of 780 citations for Dengue Virus Serotype 1 NS1 Protein HEK293 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Pharmacology and Toxicology 2023Quote: HEK293 cells were plated onto 25mm coverslips (Electron Microscopy Sciences, #50949050) coated with poly-D-lysine (Sigma Aldrich ...
-
bioRxiv - Microbiology 2023Quote: ... 3 µL of the purified CVB5 mutant virus sample at 4.5 mg mL-1 concentration was loaded onto Quantifoil R 1.2/1.3 grids (EMS), that were previously glow-discharged for 30 s in a GloCube Plus device (Quorum Technologies) ...
-
bioRxiv - Neuroscience 2020Quote: ... and 1 μL of virus mixed with Fast Green FCF Solution 2.5% (Electron Microscopy Sciences, Hatfield, PA, USA). The mouse was placed on a heating blanket (37 °C ...
-
bioRxiv - Microbiology 2020Quote: ... Mock or virus-infected cells were fixed in 4% paraformaldehyde (PFA) (Electron Microscopy Sciences, USA) for 30 min and permeabilized with 0.1% Triton X (Fisher Bioreagents ...
-
bioRxiv - Microbiology 2019Quote: ... Mock or virus-infected cells were fixed in 4% paraformaldehyde (PFA) (Electron Microscopy Sciences, USA) for 30 min and permeabilized with 0.1% Triton X (Fisher Bioreagents ...
-
bioRxiv - Cell Biology 2019Quote: HEK293 Flp-ln T-REx cells were grown on poly-L-lysine-coated #1.5 glass coverslips (Electron Microscopy Sciences). Cells were treated with 1 μg/mL doxycycline for 24 h to induce expression of BirA* or BirA*-CNAα ...
-
bioRxiv - Microbiology 2020Quote: ... the μl of virus solution were placed on glow discharged C-Flat 2/2 grids (EMS) and plunge frozen into liquid ethane using a Gatan Cryoplunge 3 ...
-
bioRxiv - Neuroscience 2020Quote: ... and filled with 0.5 µL of virus (titer ∼ 1012) dyed with Fast Green 2.5% (Electron Microscopy Sciences, Hatfield, PA, U.S.A.). The mice (∼8 weeks old ...
-
bioRxiv - Microbiology 2020Quote: Four microliters of purified virus were applied to a Formvar-and carbon-coated 400-mesh copper grid (Electron Microscopy Sciences, Hatfield, PA) for 25 seconds ...
-
bioRxiv - Microbiology 2021Quote: Four μL of purified virus was applied to a Formvar- and carbon-coated 400-mesh copper grid (Electron Microscopy Sciences, Hatfield, PA) for 25 seconds ...
-
bioRxiv - Microbiology 2021Quote: ... approximately 4 μL of purified virus sample was applied to a glow-discharged 300-mesh copper grid coated with continuous carbon film (Electron Microscopy Sciences, Hatfield, PA). The grid was plunged into a liquid ethane container that is further cooled by a liquid nitrogen bath ...
-
bioRxiv - Biophysics 2021Quote: A 10 μl volume of 5 times diluted aggregated sample (initial αS concentration = 50 µM and N-protein concentration = 0.2 – 1 μM) was deposited onto freshly cleaved mica (Muscovite mica, V-1quality, EMS, US) and left to rest for 5 min ...
-
bioRxiv - Biochemistry 2019Quote: A protein sample at 1 mg/ml concentration was plunge-frozen on 200 mesh quantifoil R1.2/1.3 grids (Electron Microscopy Sciences) using a Mark IV Vitrobot (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: The purified bison NHA2ΔN protein was individually applied to freshly glow-discharged Quantifoil R2/1 Cu300 mesh grids (Electron Microscopy Sciences). Grids were blotted for 3.0 s or 3.5 s under 100% humidity and plunge frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Microbiology 2020Quote: ... Diluted S protein was mixed with a 1.5-fold molar excess of ACE2 and the mixture was incubated on ice for 1 minute before 4.8 uL of the protein mixture was deposited on a CF400-Cu grid (Electron Microscopy Sciences) before being stained with methylamine tungstate (Nanoprobes) ...
-
bioRxiv - Molecular Biology 2021Quote: 4 µL of 0.05 mg/mL SARS-CoV-2 spike protein was applied onto a freshly glow discharged (1 min at 10 mA) CF300-Cu-50 grid (Electron Microscopy Sciences), incubated for 1 min ...
-
bioRxiv - Biochemistry 2022Quote: ... a 3-μl aliquot of the protein sample was applied to a glow-discharged Quantifoil holey carbon grid (Au 300 2/1 mesh) (Electron Microscopy Sciences), blotted for 2 s ...
-
bioRxiv - Cell Biology 2023Quote: ... The diluted sperm solution was mixed at a ratio of 1:1with 10 X concentrated 10 nm protein A-coated gold fiducials (Electron Microscopy Sciences). 2.7 μL of the mixture was applied onto the grids and blotted for 1.5 to 2.5 s in 100% relative humidity and 4 °C ...
-
bioRxiv - Cell Biology 2019Quote: ... 15 nm protein A-coated gold beads (EMS) were adhered to the grids prior to Reynolds’ lead citrate staining ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3µL of protein was applied to Quantifoil grids (EMS) that were glow-discharged for 30s at 15 mA ...
-
bioRxiv - Cell Biology 2024Quote: ... Proteins were cleaned by standard acetone precipitation (EM grade acetone; EMS). The protein pellet was resuspended in 8M Urea/50mM ammonium bicarbonate (Sigma Aldrich ...
-
bioRxiv - Microbiology 2020Quote: ... Each protein was deposited on a CF-400-CU grid (Electron Microscopy Sciences) that had been plasma cleaned for 30 seconds in a Solarus 950 plasma cleaner (Gatan ...
-
bioRxiv - Synthetic Biology 2020Quote: Purified protein samples applied to CF300-Cu carbon coated grids (Electron Microscopy Sciences) were prepared for negative stain transmission electron microscopy ...
-
bioRxiv - Microbiology 2021Quote: ... After that, Samples were infiltrated in graded mixtures (1:3, 1:1, 3:1) of resin (EMS, Resin Mixture ...
-
bioRxiv - Bioengineering 2024Quote: ... 5 μL of protein vesicle solution was dropped on a copper grid (Electron Microscopy Sciences) for 5 min at 25 °C ...
-
bioRxiv - Neuroscience 2021Quote: ... Samples were then infiltrated for 1 h with 1:1 PO:Embed 812 (EMS), and then overnight in 1:2 PO:Embed 812 ...
-
bioRxiv - Biochemistry 2019Quote: ... Diluted protein was adsorbed on freshly glow-discharged carbon-film grid (CF200-CU, Electron Microscopy Sciences), washed with dilution buffer and stained with 0.75% w/v uranyl formate ...
-
bioRxiv - Neuroscience 2019Quote: ... and placed in 1:1 100% ethanol: Hardener 1 Technovit 7100 (Electron Microscopy Sciences 14653) overnight at 4 °C ...
-
bioRxiv - Microbiology 2021Quote: ... 3μL of protein was deposited on a holey copper grids (QUANTIFOIL R 1.2/1.3, 200 mesh, EMS) which had been glow-discharged for 30s at 15 mA (Tedpella Inc) ...
-
bioRxiv - Neuroscience 2021Quote: ... the beads with enriched proteins were washed three times with 80% ethanol (Electron Microscopy Sciences Cat. #15055) followed by incubation with 100 μL 50mM ammonium bicarbonate (MilliporeSigma Cat ...
-
bioRxiv - Neuroscience 2021Quote: Protein samples were deposited on formvar/carbon-coated 200-mesh copper grids (FCF200-Cu, Electron Microscopy Sciences) for 1 min at RT ...
-
bioRxiv - Biochemistry 2022Quote: ... A 3.5 μL drop of protein was deposited on a Quantifoil-1.2/1.3 grid (Electron Microscopy Sciences) that had been glow discharged for 10 seconds using an easiGlow Glow Discharge Cleaning System (PELCO) ...
-
bioRxiv - Molecular Biology 2023Quote: ... A 2.2µL drop of protein was deposited on a Quantifoil R1.2/1.3 grid (Electron Microscopy Sciences, PA) that had been glow discharged for 10 seconds using a PELCO easiGlow™ Glow Discharge Cleaning System ...
-
bioRxiv - Neuroscience 2019Quote: ... and then placed in 1:1 propylene oxide:EMBed resin (EMS) rotating at room temperature overnight ...
-
bioRxiv - Plant Biology 2023Quote: ... nrpe1-1 (EMS), and drm1-2 (SALK_031705 ...
-
bioRxiv - Cell Biology 2023Quote: ... containing 0.1% tanic acid (EMS),1% glutaraldehyde (EMS) in anhydrous acetone (EMS ...
-
bioRxiv - Biochemistry 2022Quote: ... A 2.3-μL drop of protein was deposited on a Quantifoil-1.2/1.3 grid (Electron Microscopy Sciences, PA) that had been glow discharged for 10 seconds using a PELCO easiGlow™ Glow Discharge Cleaning System ...
-
bioRxiv - Microbiology 2021Quote: ... A 2.4-μL drop of protein was deposited on a Quantifoil-1.2/1.3 grid (Electron Microscopy Sciences, PA) that had been glow discharged for 10 seconds using a PELCO easiGlow™ Glow Discharge Cleaning System ...
-
bioRxiv - Neuroscience 2022Quote: ... EGFP expression in OB was detected using a dual fluorescent protein flashlight (Electron microscopy sciences, Hatfield, PA, USA) prior to surgery ...
-
bioRxiv - Cell Biology 2022Quote: ... 2-3 μl of protein was applied to glow-discharged carbon-coated copper grids (EMS; CF-400-Cu) and incubated for 45 s at room temperature ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3μL of protein was deposited on holey carbon copper grids (QUANTIFOIL R 1.2/1.3-2nm, 300 mesh, EMS) which had been glow-discharged for 20s at 15 mA using PELCO easiGlow (TedPella Inc) ...
-
bioRxiv - Biophysics 2023Quote: ... 5 μL of protein sample was applied to freshly-ionized carbon-coated copper mesh grids (Electron Microscopy Science). After 15 minutes ...
-
bioRxiv - Biochemistry 2023Quote: ... Four microliters of protein was loaded onto a glow-discharged CF200-CU carbon grid (Electron Microscopy Sciences, U.K.). After 5 min of incubation ...
-
bioRxiv - Immunology 2023Quote: ... A 2.4-μL drop of protein was deposited on a Quantifoil-1.2/1.3 grid (Electron Microscopy Sciences, PA) that had been glow discharged for 10 s using a PELCO easiGlow Glow Discharge Cleaning System ...
-
bioRxiv - Cell Biology 2020Quote: ... atgl-1(xd310) and atgl-1(xd314) were generated by EMS. xdIs182 (Prab-3::Cre/Podr-1::RFP ...
-
bioRxiv - Neuroscience 2020Quote: ... Samples were then embedded in 1:1 Embed-812 (EMS 14120):acetonitrile ...
-
bioRxiv - Microbiology 2023Quote: ... immediately stained with 1% uranyl acetate (Electron Microscopy Sciences, 22400-1) for 30 seconds ...
-
bioRxiv - Molecular Biology 2022Quote: 3 μl of protein solution were applied to glow-discharged carbon coated copper grid (300 mesh, Electron Microscopy Science) and let adsorb for 30 s ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μL of the protein solution was applied to a glow-discharged Formvar-carbon grid (EMS FCF200-Cu-UB) for 1 min followed by blotting ...
-
bioRxiv - Biophysics 2023Quote: A volume of 3.5 μl of purified channel protein was applied onto glow-discharged copper holey carbon grids R1.2/1.3 (Q350CR1.3, Electron Microscopy Sciences), which was cleaned for 1 minute in an H2/O2 plasma using a Gatan Solarus 950 (Gatan) ...