Labshake search
Citations for Corning :
1 - 50 of 62 citations for rno mir 206 RT PCR Primer Set since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2020Quote: C2C12 WT and miR-206 KO cells were seeded at a density of 50,000 cells/well in 6-well plates (Corning Costar). Cells were cultured in growth media for 48 hours before switching to differentiation media ...
-
bioRxiv - Molecular Biology 2020Quote: C2C12 WT and miR-206 KO myoblasts were seeded at a density of 50,000 cells/well in 6-well plates (Corning Costar), cultured in growth media for 48 hours (Day 0) ...
-
bioRxiv - Cell Biology 2020Quote: ... were set up in 96-well black-bottomed plates (Corning), and fluorescence decay was measured at 30°C.
-
bioRxiv - Developmental Biology 2024Quote: ... set on top of a 5 mL FACS tube (Corning) and collected into the same tube ...
-
bioRxiv - Cancer Biology 2020Quote: Control or miR-1236-KO (miR-1236−/−) KGN cells (5 × 106) were suspended in 0.1 mL Matrigel (1: 1, v/v, Corning, Tewksbury, MA) and injected subcutaneously into 7-week-old BALB/c nu/nu immunodeficient mice (weights ranged between 18 and 20 g ...
-
bioRxiv - Cell Biology 2020Quote: ... two sets of four T225 flasks (Corning, Cat No. 14-826-80) were seeded with 15 × 106 cells per flask and then incubated for 48 hours ...
-
bioRxiv - Biochemistry 2023Quote: FP experiments were set up in 384-well black flat bottom plates (Corning) using sample volumes of 20 μl ...
-
bioRxiv - Biochemistry 2022Quote: ... RT in black 384 well plates (Corning 3575 plates), followed by addition of 50 nM of fluorescein labeled ADP-ribosylated peptide [5Flu-ARTKQTARK(Aoa-RADP)S] ...
-
bioRxiv - Pathology 2023Quote: ... The insert was set on a 12-well plate (3401, Corning Inc., Corning, NY, USA) and cultured at 37℃ in a humidified incubator with 5% CO2 for 7 days.
-
bioRxiv - Pathology 2023Quote: ... The insert was set on a 12-well plate (3401, Corning Inc., Corning, NY, USA) and cultured at 37℃ in a humidified incubator with 5% CO2 for 7 days.
-
bioRxiv - Microbiology 2024Quote: Bioassay experiments were set up in 96-well microtiter plates (Corning Costar Assay Plate 3904), and sealed with air-permeable membranes (Breathe-Easy ...
-
bioRxiv - Biochemistry 2021Quote: ... Reactions were set up in 96 well clear plastic flat bottom corning plates (Corning, New York) with a 100μl final reaction volume ...
-
bioRxiv - Molecular Biology 2023Quote: ... an identical 96-well plate was set up for infection in white cell culture plates (Corning #C3610). At the required time intervals ...
-
bioRxiv - Biochemistry 2020Quote: ... + SAM was set up as 2 µl crystallization drops in (1µl protein:1µl reservoir solution) in 96-well plates (Corning) and equilibrated using commercially available Classics II ...
-
bioRxiv - Microbiology 2021Quote: Purified OXA-14 or OXA-935 proteins were set up as 2 µl crystallization drops (1µl protein:1µl reservoir solution) in 96-well plates (Corning) using commercially available Classics II ...
-
bioRxiv - Immunology 2019Quote: ... then combined triplicates and cleaned the PCR products with Axygen AxyPrep Mag PCR cleanup beads (Corning, #MAG-PCR-CL-50) using 1.8X volumes of beads diluted to 62.5% in water (v/v ...
-
bioRxiv - Molecular Biology 2019Quote: ... PCR purification was carried out using AxyPrep™ Mag PCR beads (Corning) and 25 μL of indexed sample at an 8:1 bead-to PCR ratio ...
-
bioRxiv - Microbiology 2023Quote: ... PCR products were purified once with AxyPrep Magnetic PCR beads (Axygen; Corning). DNA was then quantified by Qubit with the dsDNA HS Assay kit (RNA HS Assay kit was used previously for the quantification of the RNA samples ...
-
bioRxiv - Molecular Biology 2020Quote: RT-QuiC reactions were performed in black 96-well plates (COSTAR, Corning Incorporated) in which 100 μl of the reaction mixtures were loaded ...
-
bioRxiv - Biophysics 2020Quote: RT-QuiC reactions were performed in black 96-well plates (COSTAR, Corning Incorporated) in which 100 μl of the reaction mixtures were loaded ...
-
bioRxiv - Immunology 2022Quote: Replicate cultures of total PBMCs were set at different cell densities (10,000-30,000 cells/culture) in 96 U-bottom plates (Corning, 3799). Cells were cultured at 37°C in RPMI 10% Hyclone ...
-
bioRxiv - Cancer Biology 2023Quote: ... purification with Axygen® AxyPrep MAG PCR Clean-Up beads (Corning, MAG-PCR-CL), and DNA concentration quantification as above ...
-
bioRxiv - Biochemistry 2021Quote: ... Serial dilutions of binding reactions were set up in a 384-well plate (Cat No: 3575, Corning Inc., Corning, NY). Control wells with only binding buffer were also included in each experiment ...
-
bioRxiv - Biochemistry 2021Quote: ... Serial dilutions of binding reactions were set up in a 384-well plate (Cat No: 3575, Corning Inc., Corning, NY). Control wells with only binding buffer were also included in each experiment ...
-
bioRxiv - Genomics 2020Quote: ... HUVECs + si-Harbi1 NC and HUVECs+si-Harbi1 were set and 30 pmol si-Harbi1 per well in the 24-well plates (Corning-Costa) were transferred using 9 μl Lipofectamine RNAi MAX Reagent (Invitrogen ...
-
bioRxiv - Bioengineering 2022Quote: ... The mix for the tumour mass was then set into 96-well plates (Corning® Costar®, Sigma-Aldrich, Dorset, UK) and incubated in 37°C for 15 min to allow crosslinking ...
-
bioRxiv - Cancer Biology 2023Quote: Single cell experiments were set up with floating cells in an ultra-low adhesion 96-well plate (cat. no. 3474; Corning, Inc.) with one or two cells distributed into each well ...
-
bioRxiv - Bioengineering 2023Quote: ... Briefly, for monoculture models (dataset ID 2, 5 and training and test sets) Matrigel-precoated Transwell inserts (Corning Life Sciences, US) were seeded with either HGSOC cells (Table 2 ...
-
bioRxiv - Genomics 2023Quote: A reverse transcription (RT) solution was then made in molbio grade water (Corning, 46-000-CV) over ice to a final concentration of 1x RevertAid RT Buffer (comes with enzyme) ...
-
bioRxiv - Physiology 2019Quote: ... and plasma collected and transferred to pre-chilled PCR tubes (Thermowell®, Gold PCR, Corning, NY, USA) and stored at −20C° ...
-
bioRxiv - Genomics 2021Quote: ... Pooled PCR products were cleaned of excess PCR reagents via Axygen® AxyPrep FragmentSelect-I Kit (Corning, Tewksbury ...
-
bioRxiv - Microbiology 2022Quote: ... Synchronous ring-stage parasites cultured in varying concentrations of ATc (50, 3, 1, and 0 nM) were set up in triplicate in a 96-well U-bottom plate (Corning, cat. 62406-121). Dihydroartemisinin treatment (DHA ...
-
bioRxiv - Genomics 2023Quote: ... following manufacturer’s protocol. Resulting DNA was cleaned using Axygen AxyPrep MAG PCR Clean-Up Kit (cat. MAG-PCR-CL-50) (Corning, Glendale, AZ). DNA was incubated with 2X volume of magnetic bead solution on a shaker for 5 minutes ...
-
bioRxiv - Cell Biology 2019Quote: ... were incubated with the indicated concentrations of polyP300 for 10 min at RT in a clear 96-well plate (Corning). The samples were either used directly or spun down at 20,000 × g for 20 minutes at RT to remove any unbound polyP ...
-
bioRxiv - Microbiology 2021Quote: ... and pelleted by centrifugation (300 rcf, 3 min, room temperature (RT) in 15-mL or 50-mL conical tubes (Corning); then 21,000 rcf ...
-
bioRxiv - Cell Biology 2020Quote: ... The final solution was centrifuged at 100xg for 5 minutes at room temperature (RT) and the pellet containing crypts was resuspended in 1:1 Matrigel (Corning): ENR* and seeded in drops of 50 µL in 24 well plates ...
-
bioRxiv - Molecular Biology 2020Quote: ... then the aqueous post-RT material (top layer) was separated from the bottom oil layer and transferred to a nucleic acid purification column (Corning Costar Spin-X column ...
-
bioRxiv - Cell Biology 2023Quote: ... 0.2-mL Thermowell® Gold PCR Tube (Corning, Inc.) on ice ...
-
bioRxiv - Cell Biology 2023Quote: ... 0.2-mL Thermowell® Gold PCR Tube (Corning, Inc.): 2 µL purified DNA ...
-
bioRxiv - Molecular Biology 2023Quote: ... 0.2 mL polymerase chain reaction (PCR) tubes (Corning, USA) were pretreated by overnight incubation at 37°C with a 10 µL mixture of 5 ng/µL dodecyl-beta-D-maltoside (DDM ...
-
bioRxiv - Developmental Biology 2021Quote: ... for each replicate and incubated for 20 minutes at RT in a well of 96-well plate coated with Matrigel (Corning, 35248). During incubation ...
-
bioRxiv - Biochemistry 2024Quote: ... Samples and buffer blanks were filtered using 0.22 μm syringe filters and loaded into an Axygen 96-well polypropylene PCR Microplate (Corning product# PCR-96-FS-C), which was then sealed with an AxyMat Sealing Mat (product# AM-96-PCR-RD ...
-
bioRxiv - Biochemistry 2022Quote: ... Samples were prepared on a 96-well PCR plates (Corning, Thermowell gold PCR plates ...
-
bioRxiv - Cell Biology 2022Quote: ... 150 mM NaCl was added to Thermowell PCR tubes (Corning) and placed onto an ice-cold metal block ...
-
bioRxiv - Immunology 2023Quote: ... 5 μl was run on an agarose gel to confirm amplification and the remaining volume was cleaned up using Axygen AxyPrep MAG PCR cleanup beads (Corning, cat# MAG-PCR-CL-50) diluted to 62.5% in water to efficiently remove any primer dimer that would be preferentially sequenced ...
-
bioRxiv - Molecular Biology 2023Quote: ... which can be either a 384-well PCR plate (PCR384C, Corning) or an Edge-less 384-well Plate™ (1825-384E-110 ...
-
bioRxiv - Molecular Biology 2023Quote: ... and briefly dissociated by incubation with 300 µL 0.05-0.25% Trypsin-EDTA for 10 minutes at 37°C (Corning, Ref. 25-052-CI RT). Day 25 orbital shaker-cultured HLOs underwent an additional DBPS (-/- ...
-
bioRxiv - Biophysics 2020Quote: ... 32 Following development of the moulds, feature heights were verified by profilometer (Dektak, Bruker) and PDMS (Dow Corning, primer and base mixed in 1:10 ratio) applied and degassed before baking at 65 °C overnight ...
-
bioRxiv - Systems Biology 2019Quote: ... Bead-suspensions were divided into 50µl aliquots and placed into PCR tubes (Corning) followed by incubation at 25°C for 30 min and at 42°C for 90 min in a thermocycler ...
-
bioRxiv - Molecular Biology 2023Quote: ... The eluate was transferred to a new 384-well PCR plate (PCR384C, Corning) using a 16-channel pipette (INTEGRA Biosciences ...