Labshake search
Citations for Beckman :
1 - 22 of 22 citations for Bordetella Pertussis Toxin Glycerol since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... The sample was than applied on a glycerol step gradient (30-12% glycerol) and centrifuged for 15 h at 25,000 rpm (SW 32 rotor, Beckman). The separation and distribution of proteins was confirmed by SDS-PAGE gel (4–20% Mini-PROTEAN® TGX™ Precast Protein Gels ...
-
bioRxiv - Molecular Biology 2023Quote: ... 50% Glycerol) in an Ultra Clear 13.2 mL tube (Beckman Coulter, 344059), and mixed using a Gradient Master 107 IP (Biocomp) ...
-
bioRxiv - Biochemistry 2020Quote: ... Crosslinking reactions were loaded on 600µl 5∼35% glycerol gradients (Beckman 344090 tubes) in BC300N buffer and centrifuged for 4hr at 55,000rpm at 4°C in a TLS-55 rotor (with Beckman 356860 adaptors) ...
-
bioRxiv - Cell Biology 2019Quote: ... 30% 40% (v/v) glycerol solutions in 14×89 mm tubes (Beckman Instruments). The glycerol solutions were prepared in 20 mM Hepes pH 7.4 ...
-
bioRxiv - Biophysics 2020Quote: ... The sample solution was centrifuged on a 60% glycerol cushion at 100,000 rpm (Beckman TLA-100 rotor) for 15 min at 30°C to precipitate the MTs ...
-
bioRxiv - Microbiology 2020Quote: ... and separated in potassium tartrate-glycerol gradient 10–35% for 2 hrs at 175,000 ×g (Beckman SW41 Ti rotor). Purified viral particles were suspended in 10 µg/ml BSA solution or 10 µg/ml CbAE-1 solution and incubated for 1 hr at room temperature ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Linear 10–30% glycerol gradients were prepared in 11□mm□×□34□mm polyallomer centrifuge tubes (Beckman Coulter, Brea, CA) with HEM buffer [25 mM HEPES (pH 7.5) ...
-
bioRxiv - Biochemistry 2021Quote: ... 500 μl M2 eluate was added to the top of a 12 ml 15 - 35 % glycerol gradient and centrifuged in an SW40Ti rotor (Beckman) at 40 ...
-
bioRxiv - Cell Biology 2021Quote: Microtubules were sedimented onto poly-L-lysine coated coverslips by centrifuging through 20% glycerol BRB80 cushion at 4700 rpm for 2 h in S6096 rotor (Beckman). Coverslips were subsequently fixed with 20°C methanol ...
-
bioRxiv - Microbiology 2021Quote: ... and 1.3 mL of 5% (v/v) glycerol in TNE buffer) in 5 mL thin-walled Ultraclear centrifuge tubes (Beckman Coulter). Viral nucleocapsids were pelleted by centrifugation at 23,000 rpm in an SW 55 Ti rotor for 1 h at 4°C ...
-
bioRxiv - Biophysics 2022Quote: T1ST3SC12-(Ndc80)x modules were separated from Ndc80 on a 15-50% glycerol gradient of approximately 12 ml in a SW40 rotor (Beckman) for 16 hrs at 4 °C ...
-
bioRxiv - Molecular Biology 2019Quote: ... The lysate was cleared at 14,000g for 10 min and loaded on a linear 10-40% (w/v) glycerol gradient formed in SW32.1Ti ultracentrifugation tubes (Beckman Coulter) from the light (50 mM Tris-HCl ...
-
bioRxiv - Biochemistry 2021Quote: ... 1x BRB80 solution supplemented with 60 % v/v glycerol and 0.5 mM GMPCPP in a 230 μL thick-walled centrifuge tube (Beckman-Coulter). Care was taken to maintain the two distinct liquid phases ...
-
bioRxiv - Biochemistry 2020Quote: ... glycerol gradient prepared in lysis buffer (without triton) with respective amounts of glycerol using SG15 Hoefer Gradient Maker and centrifuged using SW50 (Beckman Coulter) rotor at 45,000 rpm for either 13 hours or for 14 hours 48 minutes at 4°C ...
-
bioRxiv - Microbiology 2021Quote: ... triplicate spore preparations were made in 3 ml of 20% glycerol and suspended in Isoton II (Beckman Coulter, Brea, CA, USA). The particle volume was then measured for a minimum of 100 000 particles per sample using a Multisizer 4e Coulter counter (Beckman Coulter ...
-
bioRxiv - Biochemistry 2022Quote: 1 mg of nuclear extract supplemented with protease inhibitors was carefully overlaid onto a 10 ml 10-30% glycerol gradient prepared in a polyallomer centrifuge tube (Beckman Coulter). Tubes were placed in a SW-41 swing bucket rotor and centrifuged at 4°C for 16 hours at 40,000 rpm ...
-
bioRxiv - Synthetic Biology 2021Quote: ... The complete NanoTrap was purified using rate-zonal centrifugation33 through a 1545% glycerol gradient in 1×TE + 10 mM MgCl2 in an SW 55 rotor (Beckman Coulter). Fractions were collected after a 1 hr centrifugation at 50 k rpm ...
-
bioRxiv - Molecular Biology 2023Quote: ... A 10-30% gradient of glycerol in HEMG buffer was poured into 14 x 89 mm polyallomer centrifuge tubes (Beckman #331372). The resuspended nuclear extract was carefully layered on top of the gradient and centrifuged in an SW41 rotor at 40,000 rpm for 16 hours at 4°C ...
-
bioRxiv - Biochemistry 2019Quote: ... in iso-osmolar RB150/Mg2+ (containing a reduced level (2%) of glycerol) and 80µl were transferred to 7 × 20 mm polycarbonate tubes (Beckman Coulter, Brea CA), overlaid with 80µl of 35% ...
-
bioRxiv - Microbiology 2019Quote: ... the extracts were added on top of layers in LCM buffer with 45% and 5% glycerol and ultracentrifuged at 77 000 x g for 1 h at +4°C (Beckman Coulter SW41Ti rotor). Viral nucleocapsids were recovered from the bottom of the ultracentrifuge tube ...
-
bioRxiv - Physiology 2022Quote: ... and specific kits for free fatty acids (Wako Chemicals, Neuss, Germany), glycerol (Randox Laboratories, Crumlin, UK) as well as all other parameters covered by the present study (Beckman Coulter, Brea, CA, US) 90 ...
-
bioRxiv - Cancer Biology 2022Quote: ... 1 mg of nuclear extract was deposited over a 14-mL 10-30% glycerol gradient prepared with HK buffer in a 14× 95-mm centrifuge tube (Beckman Coulter, Brea, CA Cat. # 344060) by using the Biocomp Gradient Station (Fredericton ...