bioRxiv - Biochemistry 2021Quote: ... The sucrose loaded heavy MLVs were centrifuged at 180,000 x g for 30 min at 4°C using Optima TL benchtop Ultracentrifuge (Beckman Coulter). The resulting pellets were buffer exchanged by resuspension into the assay buffer comprising 50 mM HEPES pH 7.5 ...
-
bioRxiv - Molecular Biology 2021Quote: ... Insoluble material was removed by centrifugation (100,000 x g; 30 min; 4°C; 45 Ti rotor; Optima XPN-80; Beckman Coulter). The cell lysate supernatant was passed through a Ni+2-NTA resin column (Qiagen) ...
-
bioRxiv - Molecular Biology 2021Quote: ... The membrane fraction was pelleted down by high-speed centrifugation (100,000 x g; 4°C; 30 min; 45Ti rotor; Optima XPN-80, Beckman Coulter). The membrane pellet was resuspended in solubilization buffer ...
-
bioRxiv - Molecular Biology 2021Quote: ... Ultra-centrifugation was performed (160,000 x g; 16 hours; 4°C; SW 32 Ti rotor; Optima XPN-80, Beckman Coulter) and 1mL fractions were collected and analyzed by BN-PAGE ...
-
bioRxiv - Microbiology 2021Quote: ... Concentrated supernatants were then subjected to ultracentrifugation at 160,000 x g for 2 hours at 4°C using a Beckman Ti 45 rotor (Beckman, Germany). Supernatants were completely removed and the pellet containing the crude MV fraction was resuspended in 400 μL of chilled PBS ...
-
bioRxiv - Neuroscience 2022Quote: ... The gradient was subjected to high-speed centrifugation at 100,000 x g for 2 h at 4° C using a SW41Ti rotor (Beckman Coulter). 12 fractions of 1ml each were collected from the top of the gradient ...
-
bioRxiv - Neuroscience 2022Quote: ... Lentiviral supernatant was collected 48 hours after transfection and centrifuged for 2 hours by ultracentrifugation at 25,000 RPM at 4°C (Beckman Coulter). Pellets were resuspended in DPBS and frozen in -80°C until used ...
-
bioRxiv - Neuroscience 2022Quote: ... 10 mM Tris-HCl) and centrifugated at 24,000 rpm for 1 h at 4°C in a SW41Ti Swinging-Bucket Rotor (Beckman Coulter). Supernatant was discarded and nuclei pellets were re-suspended in 800 µL of PBS ...
-
bioRxiv - Microbiology 2022Quote: ... was added before ultracentrifugation at 20,000 × g for 2 hours at 10°C in an Optima L-90K Ultracentrifuge with the SW32Ti rotor (Beckman Coulter). Supernatants were carefully discarded by aspiration and the 6 phage pellets were resuspended with 0.1 ml of TM buffer (50 mM Tris-HCl ...
-
bioRxiv - Microbiology 2020Quote: VLPs were collected after removal of cells from the enrichment culture (7,000 rpm, 20 min, Sorvall 1500 rotor) and concentrated by ultracentrifugation (40,000 rpm, 2h, 10°C, Beckman SW41 rotor). The particles were resuspended in buffer A ...
-
bioRxiv - Molecular Biology 2019Quote: ... followed by ultracentrifugation at 100,000 g for 2h in polyallomer tubes at 4 °C in a SW40 rotor (Beckman Coulter). Pelleted material was washed two times in filtered PBS at 100,000 g for 2h and re-suspended in PBS ...
-
bioRxiv - Cell Biology 2019Quote: ... and spun down at 4° C for 10 minutes at 12096×g using an Avanti J-25 centrifuge (Beckman Coulter). The sonicated lysate was incubated for 2 hours at 4 ° C with beads (Glutathione High Capacity Magnetic Agarose Beads ...
-
bioRxiv - Biochemistry 2019Quote: ... The supernatant was then slowly mixed with an equal volume of 4 M ammonium sulphate (2 M final concentration) at 4°C for 1 hour and spun at 10 K rpm using a JA-17 rotor (Beckman). Pellets containing RAD51 were suspended in 25 ml of resuspension buffer (0.5 M KCl ...
-
bioRxiv - Molecular Biology 2019Quote: ... and then centrifuged for 150 min at 39,000 rpm and 4°C in an Optima L-100XP Ultracentrifuge (Beckman-Coulter) using a SW41Ti rotor without brake ...
-
bioRxiv - Biochemistry 2019Quote: ... The supernatant from 2,000 × g was transferred to 30mL conical tube and then centrifuged at 10,000 × g for 10 min at 4°C (# Avanti J-E JA25-50 Beckman Coulter). The supernatant from this spin was filtered through a 0.22-μm mesh filter (# SLGP033RS EMD Millipore ...
-
bioRxiv - Biochemistry 2019Quote: ... The V and VI fractions were then diluted separately to a total volume of 12mL with dfPBS and centrifuged at 100,000 × g for 70 min at 4°C (# Optima-XE SW41 Beckman Coulter). The final pellet from each fraction was resuspended in 30 μL of dfPBS ...
-
bioRxiv - Cell Biology 2020Quote: ... The supernatant of MNase treated chromatin were overlaid onto the sucrose gradient and spun at 32000 rpm (124,436 rcf) for 13 h at 4 °C using SW55Ti rotor (Beckman Coulter) in Beckman Optima L80.
-
bioRxiv - Cell Biology 2020Quote: ... 1 mM EGTA) and spun at 32000 rpm (124,436 rcf) and 4 °C for 13 h using SW55Ti rotor (Beckman Coulter) in Beckman Optima L80 ...
-
bioRxiv - Synthetic Biology 2019Quote: ... then centrifuged at 5000 x g and 10°C for 10 minutes (Avanti□ J-E Centrifuge, Beckman Coulter, Indianapolis, IN). After disposing the supernatant ...
-
bioRxiv - Cell Biology 2021Quote: ... The samples were centrifuged at 4°C for 3 h at 100,000 g by using Avanti J-30XP (Beckman, USA), and the fractions were collected using a Brandel Fractionation System (USA ...
-
bioRxiv - Microbiology 2021Quote: ... The treated cells were pelleted by centrifugation at 12,000×g at 4 °C for 20 min (Beckman Allegra X-15R) and the supernatant was discarded ...
-
bioRxiv - Molecular Biology 2021Quote: ... cell lysates were cleared by centrifugation at 4 °C for 5 minutes at 16000 x g and loaded onto ice-cold 15-50 % sucrose-CHX gradients and ultracentrifuged at 4 °C for 2 hours at 274 000 x g in a SW-41Ti rotor (Beckman). Gradients were fractionated and monitored at an absorbance of 254 nm with a fraction collector (BioComp Instruments ...
-
bioRxiv - Plant Biology 2020Quote: ... The insoluble cell debris was removed via centrifugation for 30 min at 4°C and 20,000 rpm (JA-25.50, Beckman Coulter®). The supernatant was incubated for 1 h with low agitation and with 1.2 ml Glutathione-sepharose (GE-Healthcare ...
-
bioRxiv - Plant Biology 2020Quote: ... the cells were harvested by centrifuging for 30 min at 4°C and 6,000 rpm (JA-10, Beckman Coulter®). The cells were resuspended in 1x PBS (pH 7.3 ...
-
bioRxiv - Immunology 2020Quote: ... Then the concentrated supernatant was ultracentrifuged at 110,000 g for 1 hour at 4°C (Beckman Coulter L100k, company name) to sediment the vesicular fraction into a pellet ...
-
bioRxiv - Microbiology 2020Quote: ... pH 7.5) at 45,000 RPM for 45 minutes at 11 °C in a Beckman 70.1 Ti rotor (Beckman Coulter, Brea, California). The pellet was resuspended in 10 mM Tris-HCl ...
-
bioRxiv - Neuroscience 2019Quote: ... The supernatant was layered onto a 20% sucrose cushion prepared in the same lysis buffer and then centrifuged at 186,000 x g for 2 h at 4 °C in a TLA-55 rotor ultracentrifuge (Beckman Coulter). RNA was isolated from the ribosome-enriched pellet using TRIzol LS reagent according to manufacturer’s instructions (Invitrogen).
-
bioRxiv - Molecular Biology 2020Quote: ... Centrifugation was conducted at 40,000 rpm for 2 hours at 4°C in a SW-41 Ti rotor (Beckman Coulter), and fractions were collected from the top of the gradient (#1 to #20) ...
-
bioRxiv - Genomics 2021Quote: ... The tubes were then balanced and centrifuged in a Beckman Coulter L7-65 Ultracentrifuge at 25,000rpm at 4°C for 2hr using a Beckman Coulter SW28 swing bucket rotor (Beckman Coulter). The supernatant was carefully removed via aspiration ...
-
bioRxiv - Biochemistry 2019Quote: ... Ribosomes were pelleted via centrifugation at 63,000 x g for 16-18 hours at 4°C using a Type 80 Ti rotor (Beckman Coulter). Ribosome pellets were dissolved in resuspension buffer (20 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Biochemistry 2019Quote: ... Fractions containing 40S and 60S ribosomal subunits as identified via absorption at 254 nM were pelleted via centrifugation at 63,000 x g for 20 hours at 4°C using a Type 80 Ti rotor (Beckman Coulter). Ribosomal subunits were resuspended in storage buffer (30 mM HEPES-KOH pH 7.4 ...
-
bioRxiv - Biochemistry 2019Quote: ... The homogenate was centrifuged for 10 min at 10,000×g at 4°C in a Ti-70 rotor and Optima XPN-90 ultracentrifuge (Beckman Coulter) and the supernatant was removed ...
-
bioRxiv - Molecular Biology 2020Quote: ... by centrifuging at 63,000 x g for 18 hrs at 4°C using a Type 80 Ti rotor (Beckman Coulter). Pellets were resuspended and these samples were analysed by mass spectrometry.
-
Heatrich-BS enables efficient CpG enrichment and highly scalable cell-free DNA methylation profilingbioRxiv - Genomics 2021Quote: ... the sample was incubated at 25°C for 1 hour and then cleaned up by performing two rounds of 1.2x SPRI Select (Beckman Coulter). The sample was then subject to bisulfite conversion following the recommended protocol of Zymo EZ DNA Methylation kit (Zymo Research) ...
-
bioRxiv - Immunology 2021Quote: ... Ultracentrifugation in a Beckman L7-65 ultracentrifuge at 25,000 rpm for two hours at 4°C using a Beckman SW28 rotor (Beckman Coulter) was performed to pellet the viruses through the sucrose cushion while soluble egg proteins were removed ...
-
bioRxiv - Cell Biology 2020Quote: ... The ultracentrifugation (UC) steps were performed in refrigerated conditions (4°C) with rotors 50.4Ti or 70Ti (Beckman-Coulter, California, US).
-
bioRxiv - Biochemistry 2020Quote: ... Protein-liposome complexes were separated from unbound protein by centrifugation (2 h at 45.000 rpm, 4 °C, MLS50 rotor -Beckman Coulter) in the density gradient ...
-
bioRxiv - Physiology 2021Quote: ... the supernatant was ultracentrifuged at 100,000 g for 70 min at 4°C using an MLA-55 rotor (Beckman Coulter) and an Optima MAX-TL Ultracentrifuge (Beckman Coulter) ...
-
bioRxiv - Biochemistry 2021Quote: ... Samples were ultracentrifuged at 120,000 × g for 90 minutes at 4 °C in an Optima XPN-80 ultracentrifuge (Beckman Coulter) using a SW55 Ti swinging-bucket rotor (Beckman Coulter) ...
-
bioRxiv - Biochemistry 2021Quote: ... and cellular debris was removed by centrifugation at 90 000 x g for 20 min at 4°C (45 Ti rotor, Beckman). Membranes were collected by ultracentrifugation at 220 000 x g for 90 min at 4°C (45Ti rotor ...
-
bioRxiv - Cell Biology 2020Quote: ... This crude mitochondrial pellet was further purified on a discontinuous percoll gradient (buffer composition 15/23/40% sucrose) by centrifugation (40,000 x g, 1hr, 4°C) in an SW41 rotor (Beckman Coulter) and enriched mitochondria were collected from the 23-40% interface (adapted from [76]) ...
-
bioRxiv - Cell Biology 2020Quote: ... Tubes were centrifuged twice at 100,000 x g for 70 min at 4°C with a Beckman ultracentrifuge (32Ti rotor from Beckman Coulter). Supernatants were removed and the pellets resuspended in phosphate-buffered saline (PBS ...
-
bioRxiv - Microbiology 2020Quote: ... Microbial cells were collected from to 2-3 L of water samples by centrifugation at 12,000 × g and 4°C for 20 min in a high-speed centrifuge (Beckman, USA). Total genomic DNA was extracted using AxyPrep™ Genomic DNA Miniprep Kit (Axygen ...
-
bioRxiv - Microbiology 2020Quote: ... Two distinct fractions were collected from the first CsCl density gradient centrifugation (17,000 × g, 60 min, 4°C in a fixed angle MLA-55 rotor, Beckman Coulter), each were sedimented (4000 × g ...
-
bioRxiv - Molecular Biology 2021Quote: ... lysates were spun for 24 h at 4°C at 50000 rpm in a Type 70 Ti rotor (Beckman Coulter) through a 40 % (w/v ...
-
bioRxiv - Microbiology 2021Quote: ... purified by ultracentrifugation through a sucrose cushion (25% weight/volume in Tris-NaCl-EDTA buffer) for 75 min at 4°C and 28,000 rpm using a SW 32 TI rotor (Beckman Coulter), resuspended in serum-free RPMI 1640 or DMEM medium and stored in small aliquots at −80°C ...
-
bioRxiv - Immunology 2020Quote: ... all CCMV CP preparations were purified two times using an ultracentrifuge and 30% sucrose cushion – first with additional 0.5% Triton X-100 and the second time without Triton X-100 (4 h, 50 000 rmp, 4°C; Type 70Ti rotor, Beckman) and the pellet was then dissolved in buffer A ...
-
bioRxiv - Microbiology 2021Quote: ... The resting supernatants were filtered through 0.45µm syringe filters and ultracentrifuged at 100,000 x g for 1h at 4°C (SW41 Ti swinging-bucket rotor, Beckman Coulter). The supernatant was discarded and the pellet suspended in 0.22 µm-pore filtered or 0.02 µm-pore filtered (for Flow Cytometry analysis ...
-
bioRxiv - Immunology 2021Quote: ... 1×106 thawed PBMCs were centrifuged (750×g for 5 minutes at 4°C) using a swinging bucket rotor (Beckman Coulter Avanti J-15RIVD with JS4.750 swinging bucket ...
-
bioRxiv - Biochemistry 2020Quote: ... incubated under constant shaking at 37°C taken at various time points (24, 72, 168 h) were centrifuged (TL-100, Beckman) at 50k RPM (100,000 ×g ...