Labshake search
Citations for Diagenode :
1 - 50 of 303 citations for Zika Virus Vero Cell Lysate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2020Quote: ... Zirconium beads were removed from the cell lysate by centrifugation and the entire cell lysate was subject to sonication using the Bioruptor-Pico (Diagenode) for 3×10 cycles of 30 seconds ON/OFF each resulting in a final median size of chromatin fragments of 200 bp ...
-
REEP4 is recruited to the inner nuclear membrane by ELYS and promotes nuclear pore complex formationbioRxiv - Cell Biology 2020Quote: ... cell lysates were sonicated in a BioRuptur (Diagenode) for 10 intervals of 30 seconds high power ...
-
bioRxiv - Molecular Biology 2021Quote: ... The cell lysate was sheared with Biorupter (Diagenode) with 3 cycles of 30 seconds ON/OFF for 10 min each at high power ...
-
bioRxiv - Molecular Biology 2024Quote: ... Cell lysate was sonicated in a Bioruptor (Diagenode) on high setting ...
-
bioRxiv - Neuroscience 2019Quote: Tissue and cell lysates were prepared using Bioruptor (Diagenode) in RIPA buffer (10 mM Tris-HCl ...
-
bioRxiv - Microbiology 2023Quote: ... cell lysates were sonicated in a Bioruptor Pico (Diagenode) with 10 cycles of 30 s sonication pulses ...
-
bioRxiv - Cancer Biology 2020Quote: ... The cell lysates were sonicated with a Bioruptor Plus (Diagenode) for 25 cycles (30 seconds ON and 30 seconds OFF) ...
-
bioRxiv - Cell Biology 2022Quote: ... Cell lysates were sonicated for 12 rounds of 5s (Bioruptor, Diagenode) and spun down at 14,000 rpm for 10 minutes ...
-
bioRxiv - Cancer Biology 2023Quote: ... Cell lysates were sonicated for 10 cycles with Bioruptor Pico (Diagenode) until chromatin was sheared to an average length of 200 bp ...
-
bioRxiv - Immunology 2022Quote: ... Cell lysate was transferred to 1.5 ml Bioruptor Plus TPX microtube (Diagenode) and was sonicated for 4 rounds of 15 cycles of 30 seconds on/30 seconds off on high power (Diagenode Biorupter plus) ...
-
bioRxiv - Cell Biology 2023Quote: ... Crude cell lysate was harvested and sonicated by using Bioruptor Pico (Diagenode) for 13 cycles (30 seconds on and 30 seconds off) ...
-
bioRxiv - Cancer Biology 2021Quote: ... Cell lysate was sonicated with a water-bath sonicator (Diagenode Bioruptor Pico, Belgium, Germany) with cycles of 10 s on and 10 s off for five cycles ...
-
bioRxiv - Cell Biology 2020Quote: ... Lysates were sonicated (Bioruptor, Diagenode) and then quantified using Pierce BCA assay (Thermo Fisher) ...
-
bioRxiv - Immunology 2021Quote: ... Lysate was sonicated (Diagenode Biorupter) until DNA appeared with a fragment size between 100 and 500 bp on agarose gels ...
-
bioRxiv - Cancer Biology 2023Quote: ... Lysates were sonicated (Bioruptor, Diagenode) and then quantified using Pierce BCA assay (Thermo Fisher) ...
-
bioRxiv - Cancer Biology 2022Quote: ... Lysates were sonicated (Bioruptor, Diagenode) and then quantified using Pierce BCA assay (Thermo Fisher) ...
-
bioRxiv - Cell Biology 2023Quote: ... Cell lysates were sonicated for 15 min at high power with the Bioruptor sonicator (Diagenode). Protein quantification was performed using the Bradford reagent (Biorad #5000001) ...
-
bioRxiv - Genetics 2024Quote: ... Cell lysates were transferred to Diagenode 15 ml sonication tubes and sonicated (Bioruptor pico, Diagenode) 30 sec ON/ 45 sec OFF at 4°C for 60 cycles (6x10) ...
-
bioRxiv - Biochemistry 2019Quote: ... Whole-cell lysates were prepared for immunoblotting by sonicating with a Bioruptor (Diagenode, Inc., Denville, NJ) for 3 min and boiling for 15 min.
-
bioRxiv - Cancer Biology 2022Quote: ... Centrifuged cell lysates were resuspended in shearing buffer and sonicated using the Pico Bioruptor device (Diagenode) for 15 minutes (30s ON/30s OFF) ...
-
bioRxiv - Genomics 2022Quote: ... Cell lysates were then sonicated 20 times at 4°C (Bioruptor Plus, Diagenode, 30/30 cycles) and centrifuged at 14000 rpm for 1 minute at 4°C to remove cellular debris ...
-
bioRxiv - Molecular Biology 2024Quote: ... cells lysates were sonicated (15 cycles: 10 sec. on/10 sec. off) using sonicator (Bioruptor, Diagenode) and centrifuged at 12,000 g for 10 min at 4°C ...
-
bioRxiv - Cell Biology 2021Quote: ... Cell lysates were sonicated 18 cycles of 30 s on and 30 s off (Bioruptor Pico, Diagenode) and insoluble material was discarded by centrifugation at 13000rpm for 20 minutes at 4°C ...
-
bioRxiv - Neuroscience 2022Quote: ... lysates were sonicated (Bioruptor® Standard, Diagenode) on ice for 20 min in 30 s pulses and centrifuged 10.000 g for 20 min.
-
bioRxiv - Genetics 2020Quote: ... Lysates were sonicated using a BioruptorPlus (Diagenode) at 4 °C (set at 25 cycles of 25 seconds) ...
-
bioRxiv - Developmental Biology 2021Quote: ... Lysates were sonicated on a Bioruptor (Diagenode), and diluted 10x in Immunoprecipitation Dilution Buffer (Tris-HCl pH 8.1 20mM ...
-
bioRxiv - Biochemistry 2021Quote: ... Lysates were sonicated with a Bioruptor (Diagenode) at high intensity with 4 cycles of 30 s ON and 30 s OFF ...
-
bioRxiv - Neuroscience 2022Quote: ... Lysate was sonicated using a Bioruptor (Diagenode) and centrifuges at 2500 g for 10 min at 4 °C ...
-
bioRxiv - Molecular Biology 2022Quote: ... Lysates were sonicated in a Bioruptor (Diagenode) sonicator for 3 cycles (each cycle ...
-
bioRxiv - Cancer Biology 2023Quote: ... The lysates were sonicated by Bioruptor (Diagenode) at 4°C on the highest setting for 10 min (30s on and 30s off cycles ...
-
bioRxiv - Developmental Biology 2023Quote: ... The lysate was sonicated in Bioruptor (Diagenode) and centrifuged ...
-
bioRxiv - Developmental Biology 2023Quote: ... The lysate was sonicated in Bioruptor (Diagenode) and centrifuged ...
-
bioRxiv - Cancer Biology 2022Quote: ... sonicated until the lysates were clear of long DNA and other visible cell debris (Diagenode Bioruptor Plus sonicator). Lysates were processed by the Multi-Enzyme Digestion Filter Aided Sample Preparation (MED FASP ...
-
bioRxiv - Cell Biology 2020Quote: ... Lysates were immediately sonicated in a Bioruptor (Diagenode) at 4°C using highest settings with 30 seconds ON and 45 seconds OFF for 3:45 hours ...
-
bioRxiv - Cancer Biology 2019Quote: ... Nuclear lysates were prepared by sonication (Bioruptor (Diagenode), low amplitude ...
-
bioRxiv - Biochemistry 2021Quote: ... Lysates were sonicated using a Bioruptor Pico (Diagenode) for 30 minutes at 4°C ...
-
bioRxiv - Biochemistry 2021Quote: ... Lysate was sonicated using a Bioruptor Pico (Diagenode) for 30 minutes and then centrifuged at maximum speed (20000×g ...
-
bioRxiv - Cell Biology 2022Quote: ... The lysates were sonicated on a Bioruptor (Diagenode) for 30 min ...
-
bioRxiv - Genetics 2022Quote: ... Lysates were sonicated using Bioruptor (Bioruptor Standard Diagenode) for 7 minutes (15 sec ON ...
-
bioRxiv - Molecular Biology 2022Quote: ... Lysates were sonicated using a BioRuptor instrument (Diagenode) as follows ...
-
bioRxiv - Genomics 2022Quote: ... Lysates were sonicated by ultrasound homogenizer (Bioruptor, Diagenode) for 10 min at 4°C ...
-
bioRxiv - Developmental Biology 2023Quote: ... The lysate was sonicated with Bioruptor Pico (Diagenode) to shear the chromatin ...
-
bioRxiv - Neuroscience 2023Quote: ... Lysates were sheared by using a Bioruptor (Diagenode) with 10x 30s on/30s off cycles at 4°C and centrifuged at 16,000 g for 20 min ...
-
bioRxiv - Cell Biology 2023Quote: ... The lysates were sonicated in a BioRuptor (Diagenode) for 5 min (30 s on/30 s off cycle) ...
-
bioRxiv - Cancer Biology 2023Quote: ... Lysates were sonicated on a biorupter pico (Diagenode). Chromatin was diluted 4-5x using IP dilution buffer containing 1.1% Triton X-100 ...
-
bioRxiv - Cell Biology 2022Quote: ... The cell lysate was transferred to 15 mL Bioruptor Pico tubes along with ~200μL of the corresponding sonication beads (Diagenode C010200031) and sonicated using a Bioruptor Pico (Diagenode B01060010 ...
-
Pancreatic progenitor epigenome maps prioritize type 2 diabetes risk genes with roles in developmentbioRxiv - Genomics 2020Quote: ... Cells were lysed and homogenized using a Dounce homogenizer and the lysate was sonicated in a Bioruptor® Plus (Diagenode), on high for 3 × 5 min (30 sec on ...
-
bioRxiv - Genomics 2020Quote: ... Cells were lysed and homogenized using a Dounce homogenizer and the lysate was sonicated in a Bioruptor® Plus (Diagenode), on high for 3 x 5 min (30 sec on ...
-
bioRxiv - Developmental Biology 2019Quote: ... Cells were lysed and homogenised using a Dounce homogeniser and the lysate was sonicated in a Bioruptor® Plus (Diagenode), on high for 3 × 5 min (30 sec on ...
-
bioRxiv - Molecular Biology 2022Quote: ... Cross-linked cell lysates were solubilized using a multi-beads shocker (Yasui Kikai) and sonicated using a Bioruptor UCD-200 system (Diagenode). The sheared samples were centrifuged at 20,000 g for 10 min at 4°C ...