Labshake search
Citations for Harvard Apparatus :
1 - 50 of 173 citations for Rat Oxidation resistance protein 1 Oxr1 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Physiology 2022Quote: ... Borosilicate glass pipettes (resistance: 2-5 MΩ.; GC150F-7.5, Harvard Apparatus, USA) were prepared with a P-97 horizontal micropipette puller (Sutter Instrument ...
-
bioRxiv - Biophysics 2022Quote: ... Currents were recorded using borosilicate microelectrodes (Harvard Apparatus, resistance of 0.3-2 MΩ), backfilled with 3 M KCl ...
-
bioRxiv - Microbiology 2020Quote: ... and no resistance using an ECM 630 electro cell manipulator (BTX Harvard Apparatus) into ≈50% confluent T75 flasks of BHK21 cells ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes (resistance 7-8 MOhm, PG-150T-10; Harvard Apparatus, Holliston, Massachusetts) were pulled with a Brown Flaming Puller (Model P-87 ...
-
bioRxiv - Neuroscience 2023Quote: ... with 3-5 MΩ resistance glass pipette (ID: 0.69mm, OD: 1.2mm, Harvard Apparatus) filled with aCSF ...
-
bioRxiv - Neuroscience 2023Quote: ... Borosilicate glass patch pipettes (3-6 MΩ resistance) (Harvard apparatus/Science products GmbH) were filled with intracellular solution ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch electrodes (4-7 MΩ resistance) were pulled from borosilicate glass capillaries (Harvard Apparatus) using a PC-87 Micropipette puller (Sutter Instrument) ...
-
bioRxiv - Cell Biology 2020Quote: ... Pipettes (resistance 3–4 MΩ) were pulled from borosilicate glass capillaries (Harvard Apparatus, UK) using a custom-made microelectrode puller ...
-
bioRxiv - Neuroscience 2024Quote: ... Open pipette resistances were 2-5 MΩ (borosilicate glass pipette; Harvard Apparatus #30-0057). Recordings were performed using a Multiclamp 700B amplifier (Molecular Devices) ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (resistance 7–10MΩ) were fashioned from thick-walled borosilicate glass capillaries (Harvard Apparatus) pulled using a two-stage micropipette puller (PB-10 ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (resistance 7–10MΩ) were fashioned from thick-walled borosilicate glass capillaries (Harvard Apparatus) pulled using a two-stage micropipette puller (PB-10) ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (resistance 7-10MΩ) were fashioned from thick-walled borosilicate glass capillaries (Harvard Apparatus) pulled using a two-stage micropipette puller (PB-10 ...
-
bioRxiv - Neuroscience 2020Quote: ... Recording microelectrodes with resistances around 0.2–1.0 MΩ were pulled from borosilicate glass capillaries (Harvard Apparatus) using a P-1000 Flaming/Brown Micropipette Puller System (Sutter Instrument ...
-
bioRxiv - Animal Behavior and Cognition 2019Quote: ... Patch-clamp pipettes (4–6 Mohm resistance) were prepared from borosilicate glass (BF150-86-10; Harvard Apparatus) with a DMZ pipette puller (Zeitz) ...
-
bioRxiv - Neuroscience 2020Quote: ... Recording microelectrodes with resistances around 0.2 to 1.0 MΩ were pulled from borosilicate glass capillaries (Harvard Apparatus) using a P-1000 Flaming/Brown Micropipette Puller System (Sutter Instrument ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch-clamp pipettes (4-6 Mohm resistance) were prepared from borosilicate glass (BF150-86-10; Harvard Apparatus) using a DMZ pipette puller (Zeitz) ...
-
bioRxiv - Biophysics 2023Quote: ... Patch pipettes of ∼1.5 MΩ resistance were pulled from borosilicate glass capillaries (GC150TF-7.5, Harvard Apparatus Ltd.) and filled with intracellular (pipette ...
-
bioRxiv - Neuroscience 2019Quote: ... Micropipettes of 4-6 MΩ resistance were prepared from borosilicate glass capillaries (GC150-10; Harvard Apparatus, Cambridge, MA) using a horizontal puller (P-1000 ...
-
bioRxiv - Developmental Biology 2022Quote: ... Glass micropipettes with resistances of 1.5 – 4 MΩ were pulled from glass capillaries (Harvard Apparatus, #BS4 64-0792) using a Sutter P-1000 Micropipette Puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2019Quote: ... Micropipettes of 4-6 MΩ resistance were prepared from borosilicate glass capillaries (GC150-10; Harvard Apparatus, Cambridge, MA, USA) using a horizontal puller (P-1000 ...
-
bioRxiv - Neuroscience 2021Quote: Patch clamp recording pipettes (resistance:4-9 MΩ) were made from borosilicate glass capillaries (1.5 outer diameter x 0.86 inner diameter; Harvard Apparatus) and back-filled with internal solution of the following composition ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes of 4-6 MΩ resistance were pulled from standard-wall borosilicate capillaries (G150F-4, 1.5 mm outer diameter, 0.86 inner diameter, Harvard Apparatus) with a P-1000 electrode puller (Sutter Instruments) ...
-
bioRxiv - Microbiology 2023Quote: ... The mixture was then electroporated at 2 kV and 50 ohm resistance using a BTX Gemini X2 (Harvard Apparatus). Next ...
-
bioRxiv - Neuroscience 2022Quote: Extracellular single-unit recordings were made with borosilicate glass electrodes (tip diameter 1.0 – 1.5 μm, in situ resistance 10 – 25 MΩ; GC120F-10, Harvard Apparatus) filled with saline solution (0.5 M NaCl ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (resistance: 2-8 MΩ) were prepared from borosilicate glass capillaries (1.5 outer diameter x 0.86 inner diameter; Harvard Apparatus) using a Flaming/Brown micropipette puller (P-97 ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes with a resistance range of 5-6 MΩ were made from borosilicate glass capillaries (GC150T-10, Harvard Apparatus) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2021Quote: ... patch pipettes with a resistance of 1.5-3.5 MΩ were pulled from glass capillaries (Borosilicate glass, catalog #64-0792, Harvard Apparatus, USA) using a micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... Presynaptic patch pipette with open tip diameters 4-6 MΩ resistance were pulled from 1.5 mm thin-walled borosilicate glass (Harvard apparatus) and were filled with following internal solution (in mM) ...
-
bioRxiv - Microbiology 2019Quote: ... Transepithelial electrical resistance measurements was performed using Harvard/Navicyte electrodes on the EC-800 Epithelial Voltage Clamp (Harvard Apparatus, Cambridge, UK) over 24h.
-
bioRxiv - Neuroscience 2020Quote: ... were applied locally by pressure ejection from patch pipettes (resistance ∼10 MΩ; capillary inner diameter 0.86 mm, outer diameter 1.5 mm - Harvard Apparatus 30-0057) coupled to a Picospritzer III (Parker ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch recording electrodes (4-8 MΩ resistance) were pulled using a PC-10 puller (Narishige) from borosilicate glass capillaries (GC150F-10, Harvard Apparatus) and filled with a filtered voltage clamp intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: Electrodes with 3-6 MΩ tip resistance were pulled from borosilicate glass capillaries (1.7 mm outer/1mm inner diameter, Harvard Apparatus, UK) horizontal electrode puller (P-97 ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch electrodes (4-7 MΩ resistance) were pulled using a PC-10 puller (Narishige) from borosilicate glass capillaries (GC150F10, Harvard Apparatus). Slices were transferred to a submerged recording chamber and continuously perfused with oxygenated ACSF (3 mL/min ...
-
bioRxiv - Neuroscience 2023Quote: ... Current clamp and voltage clamp recordings were performed with pipettes (5- to 7-MΩ resistance) prepared from borosilicate glass (BF150-86-10; Harvard Apparatus) using a DMZ pipette puller (Zeitz) ...
-
bioRxiv - Neuroscience 2024Quote: ... bubbled with 95% O2 – 5% CO2. Patch micropipettes (open tip resistance of approx. 6 MΩ) were pulled from borosilicate glass capillaries (Harvard Apparatus), using the Sutter Instruments P97 puller and filled with the solution containing (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes were pulled to a tip resistance of 4–6 MΩ (Narishige PC-10) from borosilicate glass (GC150F, 1.5 mm, Harvard Apparatus, UK). For all the recordings except I-V relationship recordings ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch-pipettes with a resistance of 5-7 MΩ were made from borosilicate glass capillary tubes (0.86mm internal diameter; Harvard Apparatus, Cambridge, UK) using an electrode puller (P-87 ...
-
bioRxiv - Neuroscience 2024Quote: The rotarod task was used to assess motor performance and fatigue resistance in rodents using the Panlab Rota Rod model LE8205 (Harvard Apparatus, Holliston, MA). The rod was initiated to rotate at a constant initial speed of 4 RPM ...
-
bioRxiv - Neuroscience 2022Quote: ... Rats were positioned in a stereotaxic frame (Harvard Apparatus) and the skull exposed with a midline incision ...
-
bioRxiv - Neuroscience 2020Quote: ... rats were placed in a rodent restrainer (Harvard Apparatus) for 15 minutes ...
-
bioRxiv - Neuroscience 2023Quote: ... and the rats’ body temperature was maintained at a constant level of 37±1°C using a servo-controlled heating pad (Harvard Apparatus, MA, USA).
-
bioRxiv - Neuroscience 2020Quote: ... Rats were placed supine onto a stereotaxic apparatus (Type 1760; Harvard Apparatus) on a heating pad and core body temperature was maintained at a minimum of 36.5°C via a thermocouple ...
-
bioRxiv - Neuroscience 2021Quote: Anaesthetized and ventilated rats were placed in a stereotaxic frame (Harvard Apparatus) in a prone position ...
-
bioRxiv - Neuroscience 2022Quote: ... rats were tracheostomized and mechanically ventilated with the VentElite system (Harvard Apparatus), inhaling 0.9 l min-1 humidified air mixed with 0.1 l min-1 O2 ...
-
bioRxiv - Bioengineering 2021Quote: ... Rats were then hooked up to a mechanical respirator (Harvard Apparatus, 55-7040) with 1 – 2% isoflurane and 1% oxygen to allow for mechanical ventilation (∼2 - 3 mL push volume ...
-
bioRxiv - Neuroscience 2019Quote: ... rats were additionally implanted with a guide cannula (CMA 12, Harvard Apparatus, Holliston, MA), counterbalanced in the left or right NAcS (from bregma ...
-
bioRxiv - Neuroscience 2021Quote: Rats were individually placed into the center of an elevated plus maze (Harvard Apparatus) with two arms enclosed by 50 cm high walls and two open arms with no walls (each 50 cm × 10 cm ...
-
bioRxiv - Neuroscience 2019Quote: ... Rats were bilaterally infused with 0.3 µl using an infusion pump (PHD 2000; Harvard Apparatus) at a constant rate of 0.1 µl/min ...
-
bioRxiv - Neuroscience 2019Quote: ... Rats were ventilated with 3% isoflurane in 70% N2 and 30% O2 (Inspira ASV, Harvard Apparatus, Holliston, USA). Through the entire surgical procedure physiologic parameters (oxygen saturation (SpO2) ...
-
bioRxiv - Neuroscience 2021Quote: ... Rats were positioned supine and a rectal temperature probe inserted and connected to a homeothermic blanket (Harvard Apparatus) to maintain a constant body temperature of approximately 36°C ...