bioRxiv - Neuroscience 2019Quote: ... 3 months old wild type mice were anesthetized with 5% isoflurane and mounted in a stereotaxic apparatus (Harvard Apparatus). 100 nl of retrobeads were injected unilaterally using a glass micropipette at 50 nl/minute with a Quintessential Stereotaxic Injector (Stoelting) ...
-
bioRxiv - Neuroscience 2022Quote: ... wild-type mice were anesthetized with 5% isoflurane and mounted in a stereotaxic apparatus (Harvard Apparatus). 50 nL of retrobeads were injected at 100 nL/minute unilaterally using a glass micropipette with a Quintessential Stereotaxic Injector (Stoelting) ...
-
bioRxiv - Developmental Biology 2021Quote: ... Tweezer-type electrodes (Harvard Apparatus, BTX ...
-
bioRxiv - Neuroscience 2019Quote: ... Mechanical ventilation (Harvard Apparatus, Minivent type 845) was controlled through a cannulation of the trachea ...
-
bioRxiv - Neuroscience 2022Quote: ... measured with a capnograph (Type 340, Harvard Apparatus), to result in 5.0 ± 0.5 kPa blood pCO2 before administration of control or drug solutions ...
-
bioRxiv - Neuroscience 2019Quote: ... and end expiratory CO2 (Capnograph type 340; Harvard Apparatus) were monitored continuously and two arterial blood samples were drawn to assess blood gases (pO2 ...
-
bioRxiv - Neuroscience 2020Quote: ... platinum plated forceps-type electrodes (5mm Tweezertrodes -BTX Harvard Apparatus) connected to the negative pole were used to gently grab both sides of the embryo’s head and the third electrode connected to the positive pole was placed slightly below lambda50 ...
-
bioRxiv - Neuroscience 2022Quote: ... were delivered five times at 950-ms intervals by using 3-mm tweezer-type electrodes and an electroporator (BTX ECM 830, Harvard Apparatus). Embryos were returned to their dam and allowed to develop until they were harvested for analysis.
-
bioRxiv - Neuroscience 2019Quote: ... we continuously monitored end-expiratory CO2 (Capnograph type 340; Harvard Apparatus) and blood pressure (Pressure Monitor BP-1 ...
-
bioRxiv - Neuroscience 2021Quote: ... and mechanically ventilated using a MiniVent type 845 ventilator (Harvard Apparatus). During surgery ...
-
bioRxiv - Neuroscience 2020Quote: ... Rats were placed supine onto a stereotaxic apparatus (Type 1760; Harvard Apparatus) on a heating pad and core body temperature was maintained at a minimum of 36.5°C via a thermocouple ...
-
bioRxiv - Neuroscience 2022Quote: ... we monitored end-tidal respiratory CO2 levels (Type 340 capnograph; Harvard Apparatus) and arterial blood pressure via a femoral artery catheter (BP-1 Monitor ...
-
bioRxiv - Neuroscience 2019Quote: ... a tracheotomy was performed for mechanical respiration (MiniVent Type 845, Harvard Apparatus) and to monitor exhaled CO2 (MicroCapstar End-tidal CO2 Analyzer ...
-
bioRxiv - Neuroscience 2022Quote: ... embedded asteroids were placed into submersion-type recording chamber (Harvard Apparatus, Holliston, MA, USA) mounted on the stage of a customized uMs-Nikon FN1 infrared-differential interference contrast (IR-DIC ...
-
bioRxiv - Neuroscience 2023Quote: ... acute slices were placed into submersion-type recording chambers (Harvard Apparatus, Holliston, MA, USA) and visualized under Nikon E600 infrared-differential interference contrast (IR-DIC ...
-
bioRxiv - Neuroscience 2023Quote: ... Ventilation settings were optimized for each animal using a capnograph (Type 340, Harvard Apparatus) and a pulse oximeter (MouseOx® Plus ...
-
bioRxiv - Neuroscience 2021Quote: ... The ventilation settings were optimized for each animal using a capnograph (Type 340, Harvard Apparatus) and a pulse oximeter (MouseOx® Plus ...
-
bioRxiv - Neuroscience 2022Quote: ... The ventilation settings were optimized for each animal using a capnograph (Type 340, Harvard Apparatus) and a pulse oximeter (MouseOx® Plus ...
-
bioRxiv - Neuroscience 2022Quote: The percentage of exhaled CO2 was monitored in real-time (Capnograph Type 340, Harvard Apparatus), and the respiration volume and stroke frequency were adjusted when necessary ...
-
bioRxiv - Neuroscience 2020Quote: ... before transferral to an interface-type recording chamber (BSC-BU, Harvard Apparatus Inc, March-Hugstetten, USA) perfused with artificial cerebrospinal fluid (ACSF ...
-
bioRxiv - Neuroscience 2019Quote: Individual slices were then transferred and placed on a Haas-type tissue chamber (Warner Instruments, Harvard Apparatus) on a custom mesh (Warner Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... slices were individually transferred from the incubation chamber to submersion-type recording chambers (Harvard Apparatus, Holliston, MA) affixed to the stages of Nikon E600 infrared-differential interference contrast (IR-DIC ...
-
bioRxiv - Neuroscience 2023Quote: ... The slices were then transferred to a Zbicz-type BSC-PC submerged slice chamber (Harvard Apparatus, USA) filled with artificial cerebrospinal fluid (ACSF ...
-
bioRxiv - Neuroscience 2022Quote: ... 190–240 strokes/min) with O2-supplemented air (1.5–2 mL/min, MiniVent Type 845 ventilator, Harvard Apparatus). The left femoral vein and artery were then cannulated ...
-
bioRxiv - Neuroscience 2020Quote: ... Forceps-type electrodes (Nepagene) with 5 mm pads were used for electroporation using the ECM830 electroporation system (Harvard Apparatus). Embryos were collected and fixed at E15.5 ...
-
bioRxiv - Physiology 2021Quote: ... and lungs ventilated with room air or pure nitrogen via a rodent ventilator (Minivent type 845, Harvard Apparatus, USA). Respiratory rate was maintained at 200 breaths/min and tidal volume was 10 mL/kg (~250 μL) ...
-
bioRxiv - Neuroscience 2022Quote: ... to ascertain optimal blood oxygenation and for real-time monitoring of end-tidal exhaled CO2 (Capnograph Type 340, Harvard Apparatus) during the surgery and experiments ...
-
bioRxiv - Neuroscience 2020Quote: ... A tracheotomy was performed for mechanical respiration (180–220 μL volume at 190–240 strokes/min; MiniVent Type 845, Harvard Apparatus) with O2-supplemented air (1.5–2 mL/min) ...
-
bioRxiv - Neuroscience 2020Quote: ... This was achieved using a large opened tip (approximately 20μm) glass capillary (pulled from glass of the type GC100TF-10; Harvard Apparatus, UK) and gentle massage of the superficial glia with mouth suction to render the underling cell bodies accessible for the recording electrode with minimum disruption of the neuronal circuits ...
-
bioRxiv - Neuroscience 2020Quote: ... five electrical square pulses of 45V with a duration of 50 ms per pulse and 150 ms inter-pulse interval were delivered using tweezer-type electrodes connected to a pulse generator (ECM 830, BTX Harvard Apparatus). The positive pole was placed to target the developing somatosensory cortex ...
-
bioRxiv - Neuroscience 2022Quote: ... All mice underwent a tracheotomy for mechanical respiration (180-220 μl volume; 190-240 strokes/min; MiniVent Type 845 ventilator, Harvard Apparatus) to ascertain optimal blood oxygenation and for real-time monitoring of end-tidal exhaled CO2 (Capnograph Type 340 ...
-
bioRxiv - Neuroscience 2021Quote: ... Two types of recording chambers were used in the current study: a “classic” submerged-style chamber (classic chamber, RC-26GLP, Harvard Apparatus, Figure 1B) and an “interface-like” submerged-style chamber (interface-like chamber ...
-
bioRxiv - Cancer Biology 2022Quote: Particle solutions were incubated in artificial cerebrospinal fluid (aCSF, Harvard Apparatus) at 37 °C and measured by DLS at designated time points.
-
bioRxiv - Neuroscience 2020Quote: ... Viral particles were injected (750 nl) bilaterally using a syringe pump (Pump 11 Elite, Harvard Apparatus) targeted to AC (coordinates relative to bregma ...
-
bioRxiv - Microbiology 2021Quote: ... Then the whole system was sterilized overnight with 3% H2O2 at 3 ml/h using a syringe pump (Harvard Apparatus). After sterilization ...
-
bioRxiv - Neuroscience 2021Quote: ... Electrodes (3-6 MΩ, borosilicate glass Harvard Apparatus) were filled with a solution containing (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes of 3-5 MΩ (Harvard Apparatus) were made using a puller (P-1000 ...
-
bioRxiv - Bioengineering 2022Quote: DEs were generated using 3 syringe pumps (PicoPump Elite, Harvard Apparatus) for the inner ...
-
bioRxiv - Bioengineering 2019Quote: Double emulsions were generated using 3 syringe pumps (Pi-coPump Elite, Harvard Apparatus) for the inner ...
-
bioRxiv - Genomics 2022Quote: ... pH 3] and loaded onto a cation exchange Macro SpinColumn™ (Harvard Apparatus). The peptides were eluted at a gradient of buffer A for 10 minutes at room temperature ...
-
bioRxiv - Neuroscience 2023Quote: ... with 3-5 MΩ resistance glass pipette (ID: 0.69mm, OD: 1.2mm, Harvard Apparatus) filled with aCSF ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording electrodes (3-5 MΩ) were pulled from borosilicate glass tubing (Harvard Apparatus) and filled with ACSF ...
-
bioRxiv - Neuroscience 2023Quote: ... Borosilicate glass patch pipettes (3-6 MΩ resistance) (Harvard apparatus/Science products GmbH) were filled with intracellular solution ...
-
bioRxiv - Cell Biology 2020Quote: ... Pipettes (resistance 3–4 MΩ) were pulled from borosilicate glass capillaries (Harvard Apparatus, UK) using a custom-made microelectrode puller ...
-
bioRxiv - Molecular Biology 2023Quote: ... fabricated from a borosilicate glass capillary (1–3 MΩ, GC100T-10, Harvard Apparatus, USA), was placed in stratum radiatum of hippocampal CA1 ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch electrodes (3–6 MΩ) were pulled from borosilicate class (1.5 mm OD, Harvard Apparatus). For all recordings patch pipettes were filled with an internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch electrodes (3–6 MΩ) were pulled from borosilicate glass (1.5 mm OD, Harvard Apparatus). For all recordings patch pipettes were filled with an internal solution containing ...
-
bioRxiv - Neuroscience 2022Quote: ... Videos were recorded and analyzed by using FreezeFrame 3 software (Harvard Apparatus, Holliston, MA, USA).
-
bioRxiv - Neuroscience 2024Quote: ... Recording electrodes (3–6 MΩ) were pulled from borosilicate glass (1.5 mm OD, Harvard Apparatus) with a horizontal P-1000 Flaming Micropipette Puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch electrodes (3–6 MΩ) were pulled from borosilicate glass (1.5 mm OD, Harvard Apparatus). For all recordings patch pipettes were filled with an internal solution containing 130 K-Gluconate ...