1 - 50 of 218 citations for 6 Fluoro 4 hydroxy 1 7 naphthyridine 3 carbonitrile since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: ... Electrodes (3-6 MΩ, borosilicate glass Harvard Apparatus) were filled with a solution containing (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch electrodes (4-7 MΩ resistance) were pulled from borosilicate glass capillaries (Harvard Apparatus) using a PC-87 Micropipette puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2023Quote: ... Borosilicate glass patch pipettes (3-6 MΩ resistance) (Harvard apparatus/Science products GmbH) were filled with intracellular solution ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes (4-6 MΩ) were pulled from borosilicate glass capillaries (Harvard Apparatus) using a horizontal P-97 Flaming/Brown type micropipette puller (Sutter Instrument Co) ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4-6 MΩ) were pulled from borosilicate glass capillaries (Harvard Apparatus) using the vertical PC-100 puller (Narishige International Ltd ...
-
bioRxiv - Neuroscience 2023Quote: ... These guide cannulas were then used to insert the microdialysis probes (6 kDa MW cut-off, CMA 7, Harvard Apparatus) into the target sites ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch electrodes (3–6 MΩ) were pulled from borosilicate class (1.5 mm OD, Harvard Apparatus). For all recordings patch pipettes were filled with an internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch electrodes (3–6 MΩ) were pulled from borosilicate glass (1.5 mm OD, Harvard Apparatus). For all recordings patch pipettes were filled with an internal solution containing ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording electrodes (3–6 MΩ) were pulled from borosilicate glass (1.5 mm OD, Harvard Apparatus) with a horizontal P-1000 Flaming Micropipette Puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch electrodes (3–6 MΩ) were pulled from borosilicate glass (1.5 mm OD, Harvard Apparatus). For all recordings patch pipettes were filled with an internal solution containing 130 K-Gluconate ...
-
bioRxiv - Neuroscience 2023Quote: We used a standard rotarod (rod diameter 3 cm, fall height 20 cm, start speed 4 rpm, acceleration rate 1 rpm/ 8 s, Touchscreen RotaRod, Harvard Apparatus) in several consecutive testing trials performed over 7 days while blinded to genotype and simultaneously testing control littermate mice ...
-
bioRxiv - Neuroscience 2020Quote: ... Micropipettes were prepared (tip resistance between 3 and 7 MΩ) from borosilicate glass capillaries (outer diameter 1.2 mm, inner diameter 0.69 mm) (Harvard Apparatus Ltd) using a horizontal puller (Sutter) ...
-
bioRxiv - Neuroscience 2023Quote: ... Micropipettes were prepared (tip resistance between 3 and 7 MΩ) from borosilicate glass capillaries (outer diameter 1.2 mm, inner diameter 0.69 mm, Harvard Apparatus Ltd) using a horizontal puller (Sutter) ...
-
bioRxiv - Cell Biology 2020Quote: ... Pipettes (resistance 3–4 MΩ) were pulled from borosilicate glass capillaries (Harvard Apparatus, UK) using a custom-made microelectrode puller ...
-
bioRxiv - Animal Behavior and Cognition 2019Quote: ... Patch-clamp pipettes (4–6 Mohm resistance) were prepared from borosilicate glass (BF150-86-10; Harvard Apparatus) with a DMZ pipette puller (Zeitz) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch-clamp electrodes (4-6 MΩ) were prepared from filamented borosilicate glass capillaries (PG150T-7.5, Harvard Apparatus) using a micropipette puller (PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch-clamp pipettes (4-6 Mohm resistance) were prepared from borosilicate glass (BF150-86-10; Harvard Apparatus) using a DMZ pipette puller (Zeitz) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch electrodes (4-7 MΩ resistance) were pulled using a PC-10 puller (Narishige) from borosilicate glass capillaries (GC150F10, Harvard Apparatus). Slices were transferred to a submerged recording chamber and continuously perfused with oxygenated ACSF (3 mL/min ...
-
bioRxiv - Neuroscience 2021Quote: ... Recordings were made using borosilicate glass pipettes (3-6 MΩ; 0.6 mm inner diameter; 1.2 mm outer diameter; Harvard Apparatus). All signals were amplified using Multiclamp 700B (Molecular Devices ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording electrodes (3–6 MΩ) were pulled from borosilicate glass capillaries (outer diameter, 1.5 mm; 0.32 mm wall thickness; Harvard Apparatus). The glass microelectrodes were filled with a low Cl- internal solution containing the following (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... Recordings were made using borosilicate glass pipettes (3-6 MΩ; 0.6 mm inner diameter; 1.2 mm outer diameter; Harvard Apparatus). All signals were amplified using Multiclamp 700B (Molecular Devices) ...
-
A combinatory genetic strategy for targeting neurogliaform neurons in the mouse basolateral amygdalabioRxiv - Neuroscience 2024Quote: ... Recording electrodes (3–6 MΩ) were pulled from borosilicate glasses (outer diameter, 1.5 mm; 0.32 mm wall thickness; Harvard Apparatus) and filled with internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2019Quote: ... Micropipettes of 4-6 MΩ resistance were prepared from borosilicate glass capillaries (GC150-10; Harvard Apparatus, Cambridge, MA) using a horizontal puller (P-1000 ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole cell and cell attached recordings of layer five neurons within neocortex were made using 4–7 MΩ pipettes (GC150F-10, Harvard apparatus, Kent) pulled using micropipette puller (Model-P87 ...
-
bioRxiv - Neuroscience 2022Quote: ... DA neurons containing red retrobeads were recorded using borosilicate pipettes (3-4 MOhm, GC150TF, Harvard Apparatus) filled with internal solution (135 mM K-gluconate ...
-
bioRxiv - Neuroscience 2019Quote: ... Micropipettes of 4-6 MΩ resistance were prepared from borosilicate glass capillaries (GC150-10; Harvard Apparatus, Cambridge, MA, USA) using a horizontal puller (P-1000 ...
-
bioRxiv - Neuroscience 2020Quote: Electrodes with 3-6 MΩ tip resistance were pulled from borosilicate glass capillaries (1.7 mm outer/1mm inner diameter, Harvard Apparatus, UK) horizontal electrode puller (P-97 ...
-
bioRxiv - Neuroscience 2023Quote: ... Presynaptic patch pipette with open tip diameters 4-6 MΩ resistance were pulled from 1.5 mm thin-walled borosilicate glass (Harvard apparatus) and were filled with following internal solution (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... patch pipettes at 4-6 MΩ were pulled from borosilicate glass capillaries (1.5mm OD, 0.86 mm ID, Harvard Apparatus, #GC150F-10) and filled with intracellular solution containing (in mM ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes were pulled to a tip resistance of 4–6 MΩ (Narishige PC-10) from borosilicate glass (GC150F, 1.5 mm, Harvard Apparatus, UK). For all the recordings except I-V relationship recordings ...
-
bioRxiv - Molecular Biology 2023Quote: ... fabricated from a borosilicate glass capillary (1–3 MΩ, GC100T-10, Harvard Apparatus, USA), was placed in stratum radiatum of hippocampal CA1 ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes (resistance 7-8 MOhm, PG-150T-10; Harvard Apparatus, Holliston, Massachusetts) were pulled with a Brown Flaming Puller (Model P-87 ...
-
bioRxiv - Physiology 2024Quote: ... All solutions continuously superfused the cultured cells with a gravitational-driven 6-channel perfusion system through a miniature manifold (MM-6; Harvard Apparatus) at a rate of ∼0.75 ml/min ...
-
bioRxiv - Neuroscience 2021Quote: ... The craniotomy was sealed by implanting a 3 mm diameter round glass coverslip (#1, Harvard Apparatus, USA) to create a chronic cranial window.
-
bioRxiv - Microbiology 2021Quote: ... The unbound Fn was removed by a flow of PBS (6 ml hour-1) using a syringe pump (Harvard Apparatus, USA) for 15 minutes ...
-
bioRxiv - Neuroscience 2022Quote: ... was injected into V1 iontophoretically by pulses of positive DC-current (6 s on/off alterations, 6 μA, 10 min) using glass micropipettes (20 μm tip, Harvard apparatus, 30-0044). After the injection was completed ...
-
bioRxiv - Neuroscience 2022Quote: ... Tower Optical) bonded (Norland Optical Adhesive 61, Norland) to a 4 mm #1 round coverslip (Harvard Apparatus), glued in place first with tissue glue (VetBond ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (resistance 7–10MΩ) were fashioned from thick-walled borosilicate glass capillaries (Harvard Apparatus) pulled using a two-stage micropipette puller (PB-10 ...
-
bioRxiv - Neuroscience 2020Quote: ... a platelet electrode of 7 mm diameter (Tweezertrodes Model #520, BTX Instrument Division, Harvard Apparatus) was placed collaterally to the head of the embryo ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (resistance 7–10MΩ) were fashioned from thick-walled borosilicate glass capillaries (Harvard Apparatus) pulled using a two-stage micropipette puller (PB-10) ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (resistance 7-10MΩ) were fashioned from thick-walled borosilicate glass capillaries (Harvard Apparatus) pulled using a two-stage micropipette puller (PB-10 ...
-
bioRxiv - Neuroscience 2023Quote: ... at a flow rate of 0.1 μl/min for 3 min (0.25-0.3 μl total volume per side) using a syringe pump (Harvard Apparatus). Mice were subsequently maintained in individual housing for at least 2 weeks prior to CNO treatment and/or locomotor activity recording ...
-
bioRxiv - Neuroscience 2020Quote: Electroporation was with six square pulses of 7 V for 25 ms using ECM830 (Harvard Apparatus) after immersing electrodes with Hanks’ balanced salt solution supplemented with 50µg/ml kanamycin ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell current-clamp synaptic responses were recorded using glass electrodes (7-10MΩ; Harvard apparatus, UK), filled with internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: Surgery was carried out under isoflurane anesthesia (3 % induction, 1-1.5 % maintenance) while maintaining body temperature at 37°C with a heating pad (Harvard Apparatus). We delivered a subcutaneous injection of 0.1 mL Marcaine (bupivacaine 0.25% m/V in sterile water ...
-
bioRxiv - Neuroscience 2023Quote: ... A CSF tracer (6 µl) was infused at a constant rate of 1 µl/minute with a syringe pump (Harvard Apparatus, Holliston, MA, USA). During the experiment ...
-
bioRxiv - Neuroscience 2020Quote: ... Anesthesia was induced with 3% isoflurane (vol/vol) and maintained between 0.5 and 1% throughout the entire surgical procedure (Harvard Apparatus, USA). Mice were mounted on a custom-built frame with rigid earbars ...
-
bioRxiv - Neuroscience 2022Quote: ... via ear bars and a jaw bar and maintained with 1–3 % (v/v) isoflurane on a homeothermic blanket (Harvard Apparatus). Ocular lubricant was applied to the eyes ...
-
bioRxiv - Neuroscience 2022Quote: Surgery was carried out under isoflurane anesthesia (3 % induction, 1 % maintenance) while maintaining body temperature at 37°C with a heating pad (Harvard Apparatus). We delivered a subcutaneous injection of 0.1 mL Marcaine (bupivacaine 0.25 % m/V in sterile water ...
-
bioRxiv - Neuroscience 2022Quote: ... of C57Bl/6 mice using a glass pipette attached to tubing and a 1 μl Hamilton syringe in a syringe pump (Harvard apparatus; rate: 100 μl/min). The injection pipette was slowly withdrawn 5 minutes after the end of the infusion ...