Labshake search
Citations for Bio-Rad :
1 - 50 of 556 citations for Ion Exchange Chromatography since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2023Quote: ... or by ion exchange chromatography (Bio-scaleTM Mini Macro-Prep HighQ, BIORAD) for GAPd ...
-
bioRxiv - Cell Biology 2023Quote: ... cation exchange chromatography (BioRad, NGC QuestTM 10 Chromatography System #7880001 ...
-
bioRxiv - Neuroscience 2021Quote: ... The newly synthesised [14C]-MVA was purified by ion exchange chromatography (AG1-X8 resin; BioRad Laboratories, Hercules, CA, USA) and its radioactivity was measured by a liquid scintillation counter (Perkin Elmer 2100TR) ...
-
bioRxiv - Bioengineering 2022Quote: ... using: ion exchange column Aminex HPX-87H (Bio-RAD) at 60 °C ...
-
bioRxiv - Biochemistry 2023Quote: ... mixed with 40 μL ion exchange resin (Bio-RAD), and left at room temperature for 30 min to remove salts ...
-
bioRxiv - Biochemistry 2023Quote: ... Fractions containing ADDoCoV were pooled and further purified by ion exchange chromatography (IEX) using a 5 ml Bio-Scale Mini Macro Prep High Q (Bio-Rad) equilibrated in Buffer A (50 mM Tris pH 7.5 ...
-
bioRxiv - Synthetic Biology 2023Quote: ... Fractions containing Chimera were pooled and further purified by ion exchange chromatography (IEX) using a 5 ml Bio-Scale Mini Macro Prep High Q (Bio-Rad) equilibrated in Buffer A (50 mM Tris pH 7.5 ...
-
bioRxiv - Biophysics 2020Quote: ... and separated by anion-exchange chromatography (UnoQ, BioRad) with buffer A (10 mM Tris [pH 8.0] ...
-
bioRxiv - Systems Biology 2022Quote: ... broth samples were centrifuged for 5 min at 13,000 g and the supernatant was collected for analysis with a Waters alliance 2695 HPLC (Waters Chromatography B.V., Etten-Leur, The Netherlands) with an Aminex HPX-87H ion exchange column (Biorad, Hercules, CA, USA). The HPLC was operated at 60°C and 5 mM of H2SO4 was used as mobile phase at a rate of 0.6 mL/min ...
-
bioRxiv - Biochemistry 2019Quote: ... This was passed over a Macroprep HighQ ion-exchange column (BioRad), equilibrated in 8 M Urea ...
-
bioRxiv - Biophysics 2019Quote: ... The SUMO tag was cleaved by Ulp-1 as described above and the protein was further purified using ion-exchange chromatography (Bio-Rad, Hercules, California). In all purification steps ...
-
bioRxiv - Systems Biology 2022Quote: ... broth samples were centrifuged for 5 min at 13.000 g and the supernatant was collected for subjection to a Waters alliance 2695 HPLC (Waters Chromatography B.V., Etten-Leur, The Netherlands) with an Animex HPX-87H ion exchange column (Bio-Rad, Hercules, CA, USA). The HPLC was operated at 60°C and 5 mM of H2SO4 was used as mobile phase at a rate of 0.6 mL·min-1 ...
-
bioRxiv - Microbiology 2021Quote: Supernatant glucose and arabinose concentrations were analyzed by high-performance liquid chromatography (Waters Acquity UPLC® H-Class System) using an ion-exchange Aminex HPX-87H column (7.8 × 300 mm, Bio-Rad Laboratories N.V.). The analysis was carried out with an isocratic flow rate of 0.6 mL min−1 for 25 min at 50°C ...
-
bioRxiv - Biochemistry 2023Quote: ... The neutralized sample was then loaded onto a packed ion exchange resin (DOWEX H+) in a poly-prep chromatography column (Bio-Rad, 731-1550). The column was then washed with 5% acetic acid ...
-
bioRxiv - Biochemistry 2019Quote: ... coli and purified following the procedure similar to that described for CYP2B6 [22] followed by ion-exchange chromatography on Macro-Prep CM Support resin (Bio-Rad Laboratories, Hercules, CA).
-
bioRxiv - Microbiology 2021Quote: ... with an Aminex HPX-87H ion-exchange column (BioRad, Veenendaal, The Netherlands) operated at 60°C with 5 mM H2SO4 as mobile phase at a flow rate of 0.6 mL min−1 ...
-
bioRxiv - Microbiology 2022Quote: ... The reaction crude was purified by anion exchange chromatography (BioRad, AG1X8 ...
-
bioRxiv - Cell Biology 2020Quote: ... The protein was load onto an ion exchange column (Bio-Rad, Hercules, CA) and eluted with a salt gradient from 50 mM to 1 M NaCl ...
-
bioRxiv - Systems Biology 2021Quote: ... equipped with an Aminex HPX-87H ion-exchange column (BioRad, Veenendaal, The Netherlands), operated with 5 mM H2SO4 as the mobile phase at a flow rate of 0.6 mL min−1 and at 60 °C ...
-
bioRxiv - Microbiology 2021Quote: ... Ethanol and glycerol were analysed with an HPX-87H ion-exchange column (BioRad) at 60 ºC with sulphuric acid (5 mM ...
-
bioRxiv - Biophysics 2021Quote: ... we then purified using cation exchange chromatography (BioRad UNOsphere Rapid S column) with an NaCl gradient ...
-
bioRxiv - Biochemistry 2021Quote: ... Pol II peak fractions after anion-exchange chromatography (UNO Q, Bio-Rad) were pooled before buffer exchange to Pol II buffer (25 mM Na-HEPES pH 7.5 ...
-
bioRxiv - Bioengineering 2020Quote: ... and analyzed using an Aminex HPX-87H ion-exchange column (Bio-Rad, Hercules, CA USA). The column was eluted with a mobile phase of 5 mM sulfuric acid at 55°C and with a flow rate of 0.6 mL/min for 50 min ...
-
bioRxiv - Microbiology 2020Quote: ... followed by anion-exchange chromatography (Bio-Scale Mini Macro-Prep High Q; BioRad). Fractions containing the recombinant proteins were pooled and injected into a size-exclusion chromatography column (Superose12 10/300 GL ...
-
bioRxiv - Synthetic Biology 2020Quote: ... samples were analyzed using an Aminex HPX-87H ion-exchange column (Bio-Rad, Richmond, CA, USA). The column was eluted with a mobile phase of 5 mM sulfuric acid at 55°C and a flow rate of 0.6 ml/min ...
-
bioRxiv - Biochemistry 2020Quote: ... The second purification step was an ion exchange purification where a Macro-Prep High S resin (BioRad) was used ...
-
bioRxiv - Microbiology 2022Quote: Iron was removed from has samples using Chelex® 100 Chelating Ion Exchange Resin (Bio-Rad, Hercules, CA, USA) following the manufacturer’s instructions ...
-
bioRxiv - Biophysics 2021Quote: ... Urea solutions were purified by passage of the stock solution through an AG501-X8(D) ion-exchange resin (Biorad) before use74.
-
bioRxiv - Cancer Biology 2021Quote: ... The α-aminobutyrate was then derivatized by addition of TMS groups and the samples were purified by applying to an ion exchange column (AG 50W-X4, Bio-Rad), washed with water ...
-
bioRxiv - Microbiology 2021Quote: ... and glucose in samples from cultivations with molasses were separated with an Aminex® HPX-87C ion-exchange column (Bio-Rad) at 85 °C ...
-
bioRxiv - Microbiology 2020Quote: ... ethanol and 2,3-butanediol were quantified by a HPLC method using an Aminex HPX-87H 300 × 7.8 mm ion-exchange column (BioRad, Munich, Germany) heated to 60°C ...
-
bioRxiv - Physiology 2020Quote: ... Total muscle phenylalanine was isolated using cation exchange chromatography (50W-8X, 200–400 mesh H+ form; Bio-Rad Laboratories). Amino acids were eluted in 8 mL of 2N ammonium hydroxide and dried under vacuum ...
-
bioRxiv - Cell Biology 2023Quote: ... IgM-containing Capto L fractions were pooled and subjected to cation exchange chromatography using Nuvia HR-S (Bio-Rad) with an equilibrating and wash buffer (20 mM acetate ...
-
bioRxiv - Microbiology 2023Quote: ... Concentrated supernatants were flowed into anion Resource Q column (Cytiva) for anion exchange chromatography on NGC FPLC (Bio-Rad) running with pH8.0 ...
-
bioRxiv - Plant Biology 2022Quote: ... The supernatant of untagged OscobB was loaded onto an ion-exchange column (Bio-scale Mini Macro-Prep High Q Cartridge (BIORAD #732-4122) and the protein was eluted by using a NaCl gradient ...
-
bioRxiv - Epidemiology 2019Quote: Genomic DNA was individually extracted using the modified Chelex resin 10% extraction protocol (Resin Chelex100 ®, Chelating Ion Exchange Resin, Bio-Rad, France) described in [40–42] ...
-
bioRxiv - Microbiology 2020Quote: ... Maltose-1-phosphate was separated from orthophosphate by anion exchange chromatography using Dowex 1 × 8 100-200 mesh (Bio-Rad, 28 x 1.6 cm ...
-
bioRxiv - Developmental Biology 2019Quote: ... pH 8.0) prior to affinity purification by immobilized metal ion affinity chromatography (IMAC) using Chelex 100 Resin (Bio-Rad). Purified protein in PBS was mixed 1:1 with Freund’s complete adjuvant for immunization or with Freund’s incomplete adjuvant for booster injections ...
-
bioRxiv - Biochemistry 2021Quote: ... Glycosylated products were separated from unincorporated UDP-[14C]-GalNAc by anion exchange chromatography using AG1-X8 resin columns (Bio-Rad #1401454), and product incorporation was determined by liquid scintillation counting (Beckman Coulter LS6500) ...
-
bioRxiv - Cancer Biology 2024Quote: ... equipped with a 5-mL Foresight Nuvia HPQ anion-exchange column prepacked with CHT ceramic hydroxyapatite XT mixed-mode chromatography media (Bio-Rad) or 25-mL column in-house packed with the same CHT media ...
-
bioRxiv - Plant Biology 2021Quote: ... Two mL of juice was gently pushed through a one mL column packed with ion exchange resin (Bio-Rad; Mixed bed resin 272 AG501-X8) and then freeze-dried ...
-
bioRxiv - Biophysics 2021Quote: ... We centrifuged the dialysis contents to remove any insoluble protein and then purified using cation exchange chromatography (BioRad UNOsphere Rapid S column) with an NaCl gradient ...
-
bioRxiv - Physiology 2020Quote: ... Blood amino acids were extracted from 500 uL of supernatant by cation exchange chromatography (Dowex AG 50W-8X, 100–200 mesh H+ form; Bio-Rad Laboratories). Phenylalanine enrichments were determined by gas chromatography–mass spectrometry (GC-MS ...
-
bioRxiv - Microbiology 2020Quote: ... Supernatants which were recovered after enzymatic hydrolysis of the pretreated wheat straw were analyzed by high-performance liquid chromatography equipped with Aminex HPX-87H anion exchange column (Bio-Rad, USA) and a refractive index detector to analyze released monosaccharides (glucose and xylose ...
-
Actin binding domain of Rng2 sparsely bound on F-actin strongly inhibits actin movement on myosin IIbioRxiv - Biophysics 2022Quote: ... except that the protein was further purified by anion exchange chromatography with an Econo-pac High Q cartridge (BIO-RAD, Hercules, CA) before it was concentrated.
-
bioRxiv - Microbiology 2022Quote: ... The amount of glucose released was measured by high-performance liquid chromatography (HPLC) with an Aminex HPX-87H anion-exchange column (Bio-Rad, USA) and a refractive index (RI ...
-
bioRxiv - Cell Biology 2023Quote: ... Hydrolysates were analysed for their sugar content by high-performance liquid chromatography equipped with an Aminex HPX-87H anion exchange column (Bio-Rad, USA) and a refractive index detector and the percentage release was calculated citing the theoretical yield.
-
bioRxiv - Physiology 2024Quote: ... T3 was extracted from supernatants and purified through solid-phase chromatography using 200 – 400 anion exchange chloride resin (Bio-Rad, 140-1251) in Poly-Prep chromatography columns (Bio-Rad ...
-
bioRxiv - Microbiology 2021Quote: ... Excreted metabolites in the aqueous phase were measured using a high-performance liquid chromatography (HPLC) system (Waters Corporation, USA) equipped with an Aminex Ion Exclusion HPX-87H column (Bio-Rad, USA) as described previously 72.
-
bioRxiv - Immunology 2022Quote: ... cell debris was removed by centrifugation and clear supernatants were diluted 10-fold and subjected to anion exchange chromatography on gravity fed columns using AG-1 9 8 resin (formate form, 100–200 mesh size, Bio-Rad Laboratories, Hercules, CA). Fractions containing inositol mono ...