Labshake search
Citations for World Precision Instruments :
1 - 50 of 468 citations for 6H 1 3 5 Trioxepino 6 7 f benzimidazole 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Developmental Biology 2021Quote: ... Cells were patched using fire-polished 3–7 MΩ resistant borosilicate pipettes (World Precision Instruments, USA) and membrane currents and voltages were recorded in the whole-cell conFIGuration by a Digidata 1440A and a MultiClamp 700A amplifier ...
-
bioRxiv - Neuroscience 2023Quote: Patch electrodes of 5-7 MΩ resistance (thin wall, filament, 1.5 mm, WPI, Florida, USA) were pulled on DMZ Zeitz-Puller (Zeitz-Instruments Vertriebs GmbH ...
-
bioRxiv - Neuroscience 2020Quote: ... Electrodes of 4-6 MOhm resistance (borosilicate glass, World Precision Instruments, no. TW150F-3) were prepared on Narishige (PP-830 ...
-
bioRxiv - Neuroscience 2019Quote: ... Electrophysiological recordings were performed at room temperature (25 °C) with glass pipettes with open tip resistance of 3-6 MΩ (TW150F-3, World Precision Instruments, & 100µL calibrated pipettes #534332-921,VWR International) ...
-
bioRxiv - Neuroscience 2022Quote: ... A 3×5 mm2 craniotomy was drilled (Omnidrill35, World Precision Instruments) over an area covering the monocular and binocular primary visual (V1m and V1b ...
-
bioRxiv - Neuroscience 2020Quote: ... Recording patch pipettes (3-7 MΩ) were fabricated from standard-wall borosilicate glass capillary with filament (World Precision Instruments). Intracellular solution for DA PSC recording was (in mM) ...
-
bioRxiv - Developmental Biology 2023Quote: ... Ventral longitudinal muscle 6 in abdominal segments 3 or 4 was impaled with two intracellular electrodes (1 mm outer diameter borosilicate capillaries; World Precision Instruments, 1B100F-4) of ∼15 MΩ resistance (3M KCl) ...
-
bioRxiv - Physiology 2021Quote: ... juncea leaves with 100 nL ultra pure water containing 100 ng of dsIMPI or each 100 ng of dsPaGTR5/6/7/8 using a Nanoliter 2010 Injector (World Precision Instruments). A subset of the dsRNA-injected beetles were fed with detached leaves of Arabidopsis plants in plastic containers with moistened tissue for gene expression analysis (n = 6 replicates ...
-
bioRxiv - Neuroscience 2022Quote: ... Whole-cell recordings were performed using borosilicate glass patch electrodes (3-6 MΩ; World Precision Instruments, Florida) pulled on a Narishige PC-10 pipette puller (Narishige ...
-
bioRxiv - Neuroscience 2021Quote: For GBA quantification (n=5 for 4 WPI, n=3 for 8 WPI), the surface function of the Imaris software was used to select only GFP-positive cells by appropriately adjusting the number of voxels as well as the intensity of the GFP channel in the threshold tab ...
-
bioRxiv - Neuroscience 2021Quote: For GBA quantification (n=5 for 4 WPI, n=3 for 8 WPI), the surface function of the Imaris software was used to select only GFP-positive cells by appropriately adjusting the number of voxels as well as the intensity of the GFP channel in the threshold tab ...
-
bioRxiv - Neuroscience 2023Quote: ... gap-free LFP recordings (15 minute duration) were obtained from the optic tectum using a single-glass microelectrode (WPI glass #TW150 F-3) with approximately 1 μM tip diameter backfilled with 2 mM NaCl internal solution as described previously 29,37–40 ...
-
bioRxiv - Neuroscience 2020Quote: ... Viral injections were performed using a 32-gauge syringe (Hamilton Syringes Neuros, #65458) at 5-7 nl/min rate using a microsyringe pump (micro4, WPI). For multiple injections ...
-
bioRxiv - Neuroscience 2019Quote: ... 7 s ON/7 s OFF for 80 cycles) with a current controller (WPI). PHA-L (Vector Laboratories ...
-
Clemizole and Trazodone are Effective Antiseizure Treatments in a Zebrafish Model of STXBP1 DisorderbioRxiv - Neuroscience 2022Quote: ... gap-free local field potential recordings (LFP; 60 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3) filled with 2 mM NaCl internal solution (~1 μm tip diameter ...
-
bioRxiv - Neuroscience 2021Quote: ... gap-free local field potential recordings (LFP; 15 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3); ~ 1 μm tip diameter ...
-
bioRxiv - Physiology 2019Quote: ... Filamented borosilicate glass capillaries (1 mm diameter; 1B100-F-4, World Precision Instruments, Sarasota, Florida, USA) were pulled to low tip resistance (5-7 MΩ ...
-
bioRxiv - Neuroscience 2021Quote: ... we pulled 6 to 10 M-Ohm glass pipettes made of thick-walled glass (World Precision Instruments 1B150F-3) using a Sutter Instruments P-1000 puller ...
-
bioRxiv - Neuroscience 2023Quote: ... Animals were injected into their foot with 3-5 µL of 10-5 M ELH using a 10 µL Nanofil syringe (World Precision Instruments) equipped with a 35-gauge needle ...
-
bioRxiv - Neuroscience 2022Quote: ... was injected iontophoretically (0.8—1.0 μA positive current pulses with a 7 s-on/off cycle for 5 min using A365, World Precision Instruments). The coordinates of the injection were [AP −2.9 ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes with a resistance between 3-5 MΩ were pulled from borosilicate glass (WPI) with a Sutter-87 puller (Sutter) ...
-
bioRxiv - Neuroscience 2023Quote: ... Borosilicate glass pipettes were used with a resistance of 3-5 MΩ (1B150F-4; WPI). Patch clamp recordings were acquired and filtered at 10 kHz with the internal Bessel filter using a Multiclamp 700B (Molecular Devices ...
-
bioRxiv - Bioengineering 2022Quote: ... The needle was allowed to sit in place for approximately 5 min and 3-5 μL of viral vector was injected using a microsyringe pump (World Precision Instruments, UMP3) and pump controller (World Precision Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... 0.84-mm ID borosilicate glass (WPI-1B150-F) to a resistance of 2–4 MΩ using a horizontal puller (Sutter Instrument P97) ...
-
bioRxiv - Neuroscience 2020Quote: ... A 3 mm round cover glass (#1, World Precision Instruments) was placed over the exposed ...
-
bioRxiv - Neuroscience 2019Quote: ... A 3 mm glass coverslip (#1 thickness, World Precision Instruments) was glued onto the tube to seal the end that was inserted into the craniotomy ...
-
bioRxiv - Neuroscience 2022Quote: ... A 3 mm glass coverslip (#1 thickness, World Precision Instruments) was glued onto the tube to seal the end that was inserted into the craniotomy ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: Micropipettes with a tip resistance of 3–6 MΩ were prepared from 1.2/0.69-mm OD/ID borosilicate glass capillaries (World Precision Instruments, GC-120F-10) using a pipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... The recording electrodes were typically 3-5 MΩ size and were pulled from borosilicate glass (World Precision Instruments). The intracellular solution used had the following composition (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... Mice were anesthetized using 4% isoflurane (Piramal) in 100% O2 for 3 to 5 min (World Precision Instruments, Small Animal Anesthesia System ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (3-6 MΩ) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings were obtained from NAc shell MSNs using borosilicate glass pipettes (3-5 ΩM; WPI) filled with intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... patch pipettes with a resistance of 3~5 MΩ were made from borosilicate glass (World Precision Instruments, Sarasota, FL) with a Sutter Instrument P-97 micropipette puller (Novato ...
-
bioRxiv - Biophysics 2019Quote: ... Pipettes were pulled from borosilicate glass (TW150-F, World Precision Instruments); their tip diameter was adjusted within a range of 5‒10 μm ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: ... was left in place for 3 and 5 min after the first and second injections (100-nl/min, UMP3 electrical pump, WPI) to prevent backflow of the injected virus solution ...
-
bioRxiv - Neuroscience 2023Quote: ... 0.84 mm ID borosilicate glass (1B150-F; World Precision Instruments, Sarasota, FL) to a resistance of 2–4 MΩ using a horizontal puller (P-97 or P-1000 ...
-
bioRxiv - Neuroscience 2019Quote: A glass micropipette (1–3 MΩ impedance; 2-μm tip; World Precision Instruments) was connected to a pneumatic injector (3–20 PSI ...
-
bioRxiv - Neuroscience 2022Quote: ... A 3 mm round cover glass (#1, World Precision Instruments, Sarasota, FL, USA) was placed over the exposed ...
-
bioRxiv - Cell Biology 2023Quote: TEER was measured at 7-day intervals from 7-28 days in ALI cultures using an Epithelial Tissue Voltohmmeter (EVOM2) and STX2 electrodes (World Precision Instruments, Sarasota, USA). The STX2 electrodes were equilibrated in D-PBS prior to measurement ...
-
bioRxiv - Neuroscience 2020Quote: ... connected to an air pressure injector (holding pressure: < 1 PSI, injection pressure: 7 to 10 PSI; PV820 Pneumatic Picopump, WPI, USA) (Zerimech et al. ...
-
bioRxiv - Cell Biology 2023Quote: ... thin wall glass capillaries (1 mm outer diameter, 0.78 mm inner diameter; World Precision Instruments, TW100F-6) were pulled using a P-97 micropipette puller (Sutter Instruments ...
-
bioRxiv - Microbiology 2021Quote: ... cRNA was micro-injected into stage 5 or 6 oocytes using a Micro4TM micro-syringe pump controller and A203XVY nanoliter injector (World Precision Instruments, Sarasota, FLA, U.S.A.). Oocytes were maintained in oocyte Ringer’s buffer with added gentamycin (50 μg/ml ...
-
bioRxiv - Neuroscience 2022Quote: ... glass pipettes (3-8 MΩ, 1B150F-3, World Precision Instruments) were pulled using a horizontal puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... was injected into PR at 0.5 µl/min using G33 needle (Hamilton) connected to a 10 µl micro-syringe controlled by a micro-pump (WPI, UltraMicroPump 3). AM cells were recorded both before and 30 min after injection.
-
bioRxiv - Neuroscience 2020Quote: Electrical stimulation was applied through ACSF filled glass pipette (tip diameter 3–5 µm) connected to a linear stimulus isolator (A395, World Precision Instruments) was used to deliver monopolar electrical stimulation (10–90 µA ...
-
bioRxiv - Neuroscience 2021Quote: ... The patch electrodes (3-4 MΩ, World Precision Instruments; 1B150F-3) were filled with intracellular solution containing ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Freshly isolated PAs were cannulated with glass micropipettes (6 in, 1.2 mm OD; 1B120-6, World Precision Instruments) bathed with 37 °C PSS (PSS0Caplus 1.6 mM CaCl2 and without EDTA ...