Labshake search
Citations for Illumina :
1 - 50 of 9139 citations for Mouse 60S ribosomal protein L22 like 1 RPL22L1 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2020Quote: ... with ribosomal depletion using Human/Mouse/Rat Ribo-Zero kit (Epicentre/Illumina). All samples were sequenced using a 100 base-pair (bp ...
-
bioRxiv - Genomics 2022Quote: ... ribosomal RNA was removed using the Ribo-Zero Human/Mouse/Rat kit (Illumina). Sequencing libraries were generated according to the TruSeq stranded total RNA (Illumina ...
-
bioRxiv - Molecular Biology 2019Quote: ... Ribosomal RNA was depleted using the Ribo-Zero Gold rRNA Removal Kit (Human/Mouse/Rat) (Illumina) and the RNA-seq library was prepared using TruSeq Stranded mRNA Library Prep Kit (Illumina ...
-
bioRxiv - Zoology 2021Quote: ... the ribosomal RNA was removed using the Ribo-Zero-Gold (Human–Mouse–Rat) Kit (Illumina, USA) and the Ribo-Zero-Gold (Epidemiology ...
-
bioRxiv - Pathology 2021Quote: ... Ribosomal RNA depletion was carried out solely using the RiboZero Gold Human/Mouse/Rat kit (Illumina). Adapter sequences were based on the TruSeq small RNA sequences (Illumina ...
-
bioRxiv - Molecular Biology 2021Quote: ... ribosomal RNAs were removed by a Ribo-Zero Gold rRNA Removal Kit (Human/Mouse/Rat) (Illumina, RZG1224). Then ...
-
bioRxiv - Genomics 2020Quote: ... Total RNA was depleted from ribosomal RNA using Ribo-Zero rRNA Removal Kit (Human/Mouse/Rat, Illumina) followed by cDNA library preparation as described below.
-
bioRxiv - Neuroscience 2022Quote: ... All samples were depleted of ribosomal RNA using the Ribo-Zero Gold (Human/Mouse/Rat) Kit (Illumina) (replicates 1-3 and cycloheximide treated ...
-
bioRxiv - Microbiology 2021Quote: ... Host ribosomal depletion was performed using a Ribo-Zero Gold rRNA Removal Kit (Human/Mouse/Rat) (Illumina). Paired-end transcriptome sequencing was generated on the HiSeq2500 platform (Illumina).
-
bioRxiv - Developmental Biology 2019Quote: ... Ribosomal RNA was depleted from 1 µg of total RNA using Ribozero (Illumina Kit). Sequencing libraries were prepared using the NEXTflex Rapid Directional RNA-Seq Kit ...
-
bioRxiv - Molecular Biology 2019Quote: ... Total RNA was depleted of ribosomal RNA using Ribo-Zero rRNA Removal Kit (Epicentre/Illumina, Human/Mouse/Rat) and library preparation was completed using NEBNext® Ultra Directional RNA Library Prep Kit for Illumina® (New England Biolabs) ...
-
bioRxiv - Microbiology 2022Quote: ... Ribosomal RNA was removed from total RNA using the Ribo Zero Gold for human/mouse/rat kit (Illumina). Using the TruSeq RNA Sample Library Preparation v.2 kit (Illumina) ...
-
bioRxiv - Microbiology 2019Quote: ... Ribosomal RNA was removed using the RiboZero kit (Illumina). RNA-seq libraries were prepared using the ScriptSeq 2.0 Kit (Illumina) ...
-
bioRxiv - Microbiology 2023Quote: ... Ribosomal RNA was removed using the RiboZero kit (Illumina), and ribosomal RNA depletion and overall RNA quality was analysed by Bioanalyser (Agilent) ...
-
bioRxiv - Genomics 2019Quote: ... followed by the removal of ribosomal RNA using a Ribo-Zero Gold rRNA Removal Kit (Human/Mouse/Rat) (Illumina). Strand-specific sequencing libraries were prepared using a NEBNext Ultra II Directional RNA Library Prep Kit for Illumina (NEB) ...
-
bioRxiv - Microbiology 2021Quote: ... Ribosomal reduction libraries were prepared with the Ribo-Zero Gold rRNA removal kit (human/mouse/rat) MRZG12324 (Illumina, USA) and sequenced at the Yale University Center of Genome Analysis (YCGA ...
-
bioRxiv - Molecular Biology 2021Quote: ... Depletion of ribosomal RNA was carried out solely by use of the RiboZero Gold Human/Mouse/Rat kit (Illumina). Adapter sequences were based on the TruSeq small RNA sequences (Illumina) ...
-
bioRxiv - Cell Biology 2021Quote: ... Ribosomal RNA was removed with the RiboZero Gold kit (Illumina). Sequencing libraries were then prepared as previously described 108 ...
-
bioRxiv - Microbiology 2019Quote: ... and depleted of ribosomal RNA with the riboZero kit (Illumina). RNA (total ...
-
bioRxiv - Genetics 2019Quote: ... ribosomal RNAs were removed using the Ribo-Zero kit (Illumina), RNA was fragmented into 250-300bp fragments ...
-
bioRxiv - Genomics 2019Quote: ... The Agilent 2100 Bioanalyzer was used to assess RNA quality and only high quality RNA (RIN > 8) was further processed for removal of ribosomal RNA with the Ribo-Zero Magnetic Gold Kit (Human/Mouse/Rat; Illumina). Ribosomal-depleted RNA was used as input for library preparation with Illumina TruSeq V2 RNA prep kit and processed according to the manufacturer’s instruction ...
-
bioRxiv - Molecular Biology 2021Quote: ... 10 μg chromatin-associated RNAs were depleted of ribosomal RNA depletion using Ribo-Zero Magnetic Gold Kit (human/mouse/rat; Illumina), according to the manufacturer’s instruction ...
-
bioRxiv - Molecular Biology 2021Quote: ... 10 μg chromatin-associated RNAs were depleted of ribosomal RNA depletion using Ribo-Zero Magnetic Gold Kit (human/mouse/rat; Illumina), according to the manufacturer’s instruction ...
-
bioRxiv - Microbiology 2020Quote: ... ribosomal RNA (rRNA) was depleted from the total RNA extracts using the Ribo-Zero Gold (human-mouse-rat) kit (Illumina) following the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2022Quote: ... Both samples (footprints and total mRNA) went through a ribosomal RNA removal step using the Ribo-Zero Gold (Human/Mouse/Rat) Kit (Illumina). The footprint samples were then purified on a 15% TBE-Urea polyacrylamide gel (ThermoFisher Scientific ...
-
bioRxiv - Genomics 2023Quote: ... 1 µg RNA was converted to ribosomal depleted cDNA libraries ready for sequencing using the TruSeq Stranded Total RNA Library Prep Human/Mouse/Rat kit (Illumina) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2024Quote: ... total RNA from mouse gut or human donors was subjected to ribosomal RNA depletion by Ribo-Zero Plus Microbiome rRNA Depletion Kit (Illumina) and cDNA libraries were generated by using Illumina Stranded Total RNA Prep (Illumina ...
-
bioRxiv - Physiology 2021Quote: ... Ribosomal RNA was removed using Ribo-Zero rRNA removal kit (Illumina) and the purity and integrity assessed using Bioanalyzer 2000 (Agilent Technologies ...
-
bioRxiv - Microbiology 2020Quote: ... followed by ribosomal RNA depletion using a bacterial ribozero kit (Illumina) prior to library preparation for ribosome profiling ...
-
bioRxiv - Neuroscience 2022Quote: ... Ribosomal RNA was depleted with the Gold Ribo-Zero kit (Illumina). Resulted RNA samples were resolved by electrophoresis in a 15% NOVEX TBE-Urea gel (Thermo Fisher) ...
-
bioRxiv - Neuroscience 2022Quote: ... Ribosomal RNA was depleted with the Gold Ribo-Zero kit (Illumina). After depletion 80 ng of each RNA sample was used to synthesized cDNA and make a library using the NEBNext Ultra Directional RNA library kit for Illumina (NEB).
-
bioRxiv - Microbiology 2021Quote: ... Ribosomal RNA was depleted with Ribo-Zero rRNA Removal Kit (Illumina). Then ...
-
bioRxiv - Microbiology 2019Quote: ... Ribosomal RNA depletion was performed using the Ribo-Zero kit (Illumina) for all libraries with the modifications prescribed by (12) ...
-
bioRxiv - Genomics 2019Quote: ... Ribosomal RNAs were depleted using Ribo-Zero Magnetic Gold Kit (Illumina). Samples were sequenced in an Illumina NextSeq 500 instrument.
-
bioRxiv - Genomics 2020Quote: ... ribosomal RNA was removed by the KAPA RNA HyperPrep Kit (Illumina). The resulting RNA was subjected to strand-specific library preparation using the SENSE mRNA-Seq Library Prep Kit V2 (Lexogen) ...
-
bioRxiv - Microbiology 2020Quote: ... ribosomal RNA was further depleted using the RiboZero Bacteria Kit (Illumina). Library preparation was done with the KAPA Stranded Total RNA Kit (Kapa Biosystems) ...
-
bioRxiv - Microbiology 2021Quote: ... Ribosomal RNA depletion was performed using the Bacteria RiboZero kit (Illumina). From rRNA-depleted RNA ...
-
bioRxiv - Microbiology 2022Quote: Ribosomal RNA was removed with the Ribo-Zero Bacteria kit (Illumina). The RNA-seq libraries were prepared using a TruSeq Stranded mRNAseq Sample Prep kit with each sample individually ligated with unique adapters (Illumina) ...
-
bioRxiv - Plant Biology 2022Quote: ... ribosomal RNA was removed by Ribo-Zero™ Magnetic Kit (Illumina) and rRNA free residue was cleaned up by ethanol precipitation ...
-
bioRxiv - Microbiology 2023Quote: ... Ribosomal RNA depletion was performed using the Bacteria RiboZero kit (Illumina). From rRNA-depleted RNA ...
-
bioRxiv - Microbiology 2023Quote: ... Ribosomal RNA depletion was performed using the Bacteria RiboZero kit (Illumina). From rRNA-depleted RNA ...
-
bioRxiv - Physiology 2023Quote: ... Ribosomal RNA was removed with the Ribozero HMR Gold kit (Illumina).
-
bioRxiv - Cancer Biology 2023Quote: ... and depleted from ribosomal rRNA using Ribo-zero Removal kit (Illumina). RNA quality and quantity were assessed by SS RNA kit on Fragment Analyzer (Agilent ...
-
bioRxiv - Microbiology 2023Quote: ... Ribosomal RNA was removed with Ribo-Zero rRNA depletion kit (Illumina) prior to cDNA synthesis using random hexamer primers ...
-
bioRxiv - Molecular Biology 2023Quote: ... Ribosomal RNA was removed with the Ribo-Zero Magnetic Kit (Illumina). Clean reads (Q30 > 94% ...
-
bioRxiv - Molecular Biology 2023Quote: ... Ribosomal RNA depletion was performed with the RiboZero Gold kit (Illumina), and libraries were constructed using the SmarterStranded V2 kit (Takara Bio) ...
-
bioRxiv - Microbiology 2024Quote: ... Ribosomal RNA was removed using Ribo-Zero rRNA Depletion Kit (Illumina) and paired-end sequencing (2×150 bp ...
-
bioRxiv - Molecular Biology 2020Quote: Ribosomal RNA was depleted from the total RNA using the Ribo-Zero Gold rRNA removal kit (Human/Mouse/Rat) (Illumina, USA). The ribo-depleted RNA was used to create an ssRNA-Seq library ...
-
bioRxiv - Genetics 2019Quote: ... including ribosomal depletion (Illumina). Samples were sequenced on NovaSeq6000 (NovaSeq Control Software 1.4.0/RTA v3.3.3 ...
-
bioRxiv - Genomics 2020Quote: ... Ribosomal RNA was depleted and purified using Ribo-Zero rRNARemoval Kit (Illumina) and RNA Clean and Concentrator-5 (Zymo Research) ...