Labshake search
Citations for Illumina :
1 - 50 of 2140 citations for 8 Benzyloxy 5 R 2 bromo 1 hydroxyethyl 1H quinolinone since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... The purified PCR products were then processed and sequenced using the NextSeq 75 – High Output (82 cycles in read 1, 8 cycles in index 1, and 8 cycles in index 2 SE reads) (Illumina). The sequencing data was analyzed using the Model-Based Analysis of Genome-wide CRISPR/Cas9 Knockout (MAGeCK ...
-
bioRxiv - Neuroscience 2023Quote: ... Libraries were sequenced Paired-End 151 bases (in addition: 8 bases for index 1 and 8 bases for index 2) setup using the NovaSeq 6000 instrument (Illumina) and the S1 Flow-Cell loaded at a final concentration in Flow-Lane loaded of 340pM and including 1% PhiX.
-
bioRxiv - Neuroscience 2024Quote: ... Libraries were sequenced Paired-End 51 bases (in addition: 8 bases for index 1 and 8 bases for index 2) setup using the NovaSeq 6000 instrument (Illumina). SP Flow-Cell was loaded at a final concentration in Flow-Lane loaded of 400pM and including 1% PhiX ...
-
bioRxiv - Neuroscience 2024Quote: ... Libraries were sequenced Single-reads 76 bases (in addition: 8 bases for index 1 and 8 bases for index 2) on NextSeq 500 (Illumina) using the NextSeq 500 High Output Kit 75-cycles (Illumina ...
-
bioRxiv - Neuroscience 2019Quote: ... Index 2: 8 cycles) across 2 runs on a NextSeq 500 (Illumina) with an average read depth across biological replicates of 8,815 reads per cell.
-
bioRxiv - Genomics 2019Quote: ... and three mate-pair libraries (insert sizes of 2 kb, 5 kb, and 8 kb) were constructed using the TruSeq PCR-free Kit (Illumina) and Mate-pair Kit (Illumina) ...
-
bioRxiv - Cell Biology 2021Quote: ... 8 bases for index 1 and 8 bases for index 2) using the NextSeq 500 High Output Kit 75-cycles (#FC-404-1005, Illumina) loaded at 1.8pM and including 1 % PhiX ...
-
bioRxiv - Cancer Biology 2021Quote: ... Libraries were sequenced 2 * 50+8+16 bp on a HiSeq2500 sequencer (Illumina). RNA-seq data were processed according to Doyle et al ...
-
bioRxiv - Genetics 2020Quote: ... Pooled and denatured library (8 pM) containing 5% volume of PhiX (control library; Illumina) was sequenced using the Illumina MiSeq system with MiSeq Reagent Kit V3 (300-bp paired-end reads ...
-
bioRxiv - Developmental Biology 2022Quote: ... Extracted DNA was PCR-amplified (F 5’ – GTGCCTTCTCCGTCAGTCTC – 3’, R 5’ – GCAGGCACAAATCCAAGTTT – 3’, and subsequently subjected to next-generation sequencing in an Illumina MiSeq platform 116 ...
-
bioRxiv - Systems Biology 2020Quote: ... i7 index 8 cycles and Read 2 56 cycles on a NextSeq500 instrument (Illumina) using High Output v2.1 chemistry ...
-
bioRxiv - Microbiology 2021Quote: ... 5 in treatment d28_0 and 5 from d28_100 (Illumina HiSeq, 2×150bp, GenoScreen, France). Reads corresponding to animal sequences were identified by aligning each dataset against Oryzias latipes available at the NCBI ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... sample 2 was treated with 20 U RNase R (Epicentre/Illumina, Cat. No. RNR07250) for 1 h at 37°C to degrade linear RNAs ...
-
bioRxiv - Microbiology 2023Quote: ... for each sample 2 μl of 5’ adapter (Illumina) (total 12 μl ...
-
bioRxiv - Immunology 2023Quote: ... 8 bp Index 1 on a NextSeq 550 sequencer (Illumina). Primers used for sample indexing PCR are listed in Extended Data Table 5.
-
bioRxiv - Cell Biology 2024Quote: ... 8 bases for index 1 and 8 bases for index 2) on NextSeq 500 using the NextSeq 500 High Output Kit 75-cycles (Illumina, Cat# FC-404-1005). Flow lanes were loaded at 1.8pM ...
-
bioRxiv - Cell Biology 2024Quote: ... 8 bases for index 1 and 8 bases for index 2) on NextSeq 500 using the NextSeq 500 High Output Kit 75-cycles (Illumina, Cat# FC-404-1005). Flow lanes were loaded at 1.8pM ...
-
bioRxiv - Genomics 2019Quote: ... and with short reads using Pilon (two runs; Illumina library; Figure 1h).
-
bioRxiv - Systems Biology 2020Quote: ... Cohort 2 gene expression data were measured using a Human Ref-8 BeadChip array (Illumina, Inc) with ∼22k probes ...
-
bioRxiv - Immunology 2022Quote: ... Index read 1:8 cycles or on a HiSeq X (Illumina), using a 150 cycle flowcell with the read configuration ...
-
bioRxiv - Genomics 2022Quote: ... 5 μl of Index primer (both provided in NEBNext Multiplex Oligos for Illumina Index Primers Sets 1 and 2), and 25 μl NEBNext Ultra II Q5 Master Mix (PCR cycling conditions ...
-
bioRxiv - Genomics 2023Quote: ... The transposition reaction was incubated for 30 min or 1h at 37◦C (Illumina Tagment DNA Enzyme and Buffer kit ...
-
bioRxiv - Genomics 2021Quote: ... Libraries were generated from 2-5 μg of genomic DNA using the TruSeq 2 library preparation kit (Illumina, USA). Two types of libraries were prepared ...
-
bioRxiv - Neuroscience 2020Quote: ... and sequenced them using PE100 reads and 2 × 8 bp index reads on a Novaseq 6000 Sequencing System (Illumina) aiming for 1 million reads per cell.
-
bioRxiv - Genomics 2021Quote: ... The cell pellets were then resuspended in 20 μl, 10 μl, and 8 μl of transposition mix (25 μl 2×TD buffer, 2.5 μl Tn5 (Illumina), 16.5 μl PBS (Invitrogen) ...
-
bioRxiv - Genomics 2021Quote: ... The samples were amplified for 5-8 cycles as determined by qPCR for Illumina sequencing using Nextera library preparation kit (Illumina) and samples were paired-end sequenced on HiSeq4000 ...
-
bioRxiv - Genomics 2023Quote: ... We used 15 mins incubation on ice in the nuclei preparation step and the Tn5 reaction was performed in 50 μl of custom transposition buffer (10 mM Tris pH 8, 5 mM MgCl2 and 10% dimethylformamide) with 2.5 μl Tn5 transposase (Illumina, 20034197) at 37°C while mixing at 1000 rpm for 30 mins ...
-
bioRxiv - Immunology 2020Quote: ... The enriched B cell libraries were sequenced in NextSeq or MiSeq sequencer using NextSeq Mid Output v2.5 sequencing reagent kit (read length: 2 × 150 bp) or MiSeq Reagent Kit v2 (read length: 2 × 150 bp) (Illumina) respectively.
-
bioRxiv - Bioengineering 2024Quote: ... with 2 × 151 bp paired-end dual indexed (2 × 8 bp) reads or using the Nextera DNA Flex Library Preparation Kit (20018705; Illumina) on the NovaSeq6000 sequencer (Illumina ...
-
bioRxiv - Molecular Biology 2020Quote: ... 12 times 8 Nextera (Illumina) based primer combinations were used ...
-
bioRxiv - Microbiology 2021Quote: ... 8) DC3000 − B (Illumina only), 9 ...
-
bioRxiv - Cancer Biology 2024Quote: ... 5’-AATGATACGGCGACCACCGAGATCTACACTCTTT CCCTACACGACGCTCTTCCGATCTTGGAAC TGCTGTTTCCCACTT-3’ for bait 2 (Illumina prefix appended to downstream primer). The bait sequences for the IRX3 proximal promoter were ...
-
bioRxiv - Cancer Biology 2024Quote: ... 5’-AATGATACGGCGACCACCGAGATCTACACTCTTT CCCTACACGACGCTCTTCCGATCTTGCAGGA GCCCGAAGCA-3’ for bait 2 (Illumina prefix appended to downstream primer) and ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... we added four mate pair libraries (3 kb, 5 kb, 7 kb, 8 kb) prepared using a Nextera Mate Pair Library Prep kit (Illumina, San Diego, CA, USA). Each library was sequenced on an Illumina HiSeq 2500 sequencer by Novogene (Sacramento ...
-
bioRxiv - Molecular Biology 2020Quote: ... the NEBNext Ultra II DNA Library Preparation kit was used to generate libraries using 5-10 ng of input or immunoprecipitated DNA and barcode adaptors (NEBNext Multiplex Oligos for Illumina (Set 1, E7335 and Set 2, E7500)) ...
-
bioRxiv - Genetics 2021Quote: ... 1 µg of high quality total RNA sample (RIN >8) was processed using TruSeq Stranded mRNA kit (Illumina) according to manufacturer instructions ...
-
A New Gene Set Identifies Senescent Cells and Predicts Senescence-Associated Pathways Across TissuesbioRxiv - Cell Biology 2021Quote: ... and 2-5 cm inferior to the navel.24,38 Sequencing was performed on a HiSeq2000 (Illumina®), fastq files were mapped to the human reference genome hg19 ...
-
bioRxiv - Immunology 2022Quote: ... 5,000-50.000 cells per experiment were centrifuged 5 minutes at 8°C, and resuspended in 25 µl transposase mixture (12.5 µl Tagmentation DNA buffer, 1 µl Tn5 transposase (Illumina), 10.75 µl nuclease-free water ...
-
bioRxiv - Cancer Biology 2022Quote: ... The cell pellet was then mixed and incubated at 37°C for 1h min with the transposition reaction mix prepared using Illumina Tagment DNA Enzyme and Buffer kits (Illumina, 20034197). DNA was then purified using DNA Clean and Concentrator kit (Zymo ...
-
bioRxiv - Microbiology 2023Quote: ESC-R-Ec isolates were sequenced by Illumina NovaSeq 6000 or Illumina MiSeq as previously described (33) ...
-
bioRxiv - Genomics 2020Quote: ... Other libraries were sequenced on NextSeq 500 (1x 28 / 1×91 cycles plus 8 base index cycle) using the v2 150 cycle High Output kit (Illumina) as per the manufacturer’s instructions ...
-
bioRxiv - Genomics 2021Quote: ... Lab 1 and 2 sequenced DNA with a NovaSeq 6000 (Illumina,
-
bioRxiv - Cancer Biology 2021Quote: ... on Thermo Fisher Scientific’s Quantstudio 5 before multiplex pooling and sequencing a 2×100 flow cell on the NovaSeq platform (Illumina) at the Collaborative Sequencing Center.
-
bioRxiv - Genetics 2024Quote: ... we aligned the corresponding short reads to the human reference GRCh38 using bwa mem23 (v 0.7.17-r1188; -t 48 -R “@RG\tID:1\tLB:lib1\tPL:ILLUMINA\tSM:
\tPU:unit1”). Next ... -
bioRxiv - Genomics 2020Quote: ... Genotyping was performed using Infinium Omni2.5-8 arrays (Illumina) at the UCSD Institute for Genomic Medicine ...
-
bioRxiv - Genomics 2020Quote: ... Genotyping was performed using Infinium Omni2.5-8 arrays (Illumina) at the UCSD Institute for Genomic Medicine ...
-
bioRxiv - Molecular Biology 2023Quote: Ribo-Zero Magnetic Kit H/M/R (Epicentre/Illumina) was used to remove ribosomal RNAs and to enrich mRNAs ...
-
bioRxiv - Microbiology 2019Quote: ... The resulting amplicon library pool was diluted to 2 nM with sodium hydroxide and 5 mL were transferred into 995mL HT1 (Illumina) to give a final concentration of 10 pM ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... The ~2 kb jumping library was prepared using the 2-to-5-kb insert Illumina Mate-pair library prep kit (V2; Illumina) as previously described [79] ...
-
bioRxiv - Microbiology 2022Quote: ... A 2.5 kb jumping library was prepared using the 2-to-5-kb insert Illumina Mate-pair library prep kit (V2; Illumina). These libraries were sequenced at the Broad Institute Genomics Platform on an Illumina HiSeq 2000 system to generate paired 101-base reads ...