Labshake search
Citations for Illumina :
1 - 50 of 591 citations for 7 BENZYLOXY 3 METHYL 5 NITROINDOLE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Physiology 2021Quote: ... 3’ and 5’ adaptors (Illumina) were ligated and the resulting product was reverse transcribed to generate cDNA by PCR ...
-
bioRxiv - Biochemistry 2024Quote: Forward Illumina Adapter: 5’-ACACTCTTTCCCTACACGACGCTCTTCCGATCTXXXX-3’ Reverse Illumina Adapter: 5’-GACTGGAGTTCAGACGTGTGCTCTTCCGATCTXXXX-3’ Next generation (Illumina) sequencing was performed by Azenta (Amplicon-EZ) ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... we added four mate pair libraries (3 kb, 5 kb, 7 kb, 8 kb) prepared using a Nextera Mate Pair Library Prep kit (Illumina, San Diego, CA, USA). Each library was sequenced on an Illumina HiSeq 2500 sequencer by Novogene (Sacramento ...
-
Microplastic consumption induces inflammatory signatures in the colon and prolongs a viral arthritisbioRxiv - Immunology 2021Quote: ... for RNA extraction and 16S sequencing using V3-V4 region primers (Forward 5’- CCTAYGGGRBGCASCAG -3’ and Reverse 5’- GGACTACNNGGGTATCTAAT -3’. Sequencing was performed on an Illumina MiSeq platform.
-
bioRxiv - Developmental Biology 2022Quote: ... Extracted DNA was PCR-amplified (F 5’ – GTGCCTTCTCCGTCAGTCTC – 3’, R 5’ – GCAGGCACAAATCCAAGTTT – 3’, and subsequently subjected to next-generation sequencing in an Illumina MiSeq platform 116 ...
-
bioRxiv - Microbiology 2019Quote: ... the 16S rRNA sequences covering the V6-V7-V8 variable regions (5’ ACACTGACGACATGGTTCTACA 3’ and 5’ TACGGTAGCAGAGACTTGGTCT 3’) were PCR amplified and sequenced by Illumina MiSeq PE250 (paired-end) ...
-
bioRxiv - Microbiology 2020Quote: ... Microbiome communities in ligatures were characterized by sequencing of the 16S rRNA V1-V2 region using primers 8F 5’- AGAGTTTGATCMTGGCTCAG-3’ and 361R 5’- CYIACTGCTGCCTCCCGTAG-3’ which included the adapter for MiSeq sequencing (Illumina) and single end barcodes (4) ...
-
bioRxiv - Microbiology 2023Quote: The V3/V4 variable region of the 16S rRNA gene was amplified using primers 341F 5’CCTACGGGNGGCWGCAG′3 and 785R 5′GACTACHVGGGTATCTAATCC′3 (Klindworth et al., 2013 with Illumina Nextera XT overhang adapters for a dual-barcoding PCR library preparation approach ...
-
bioRxiv - Molecular Biology 2023Quote: ... for 1[h at 60°C and was subsequently PCR amplified using the primers 5′-AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTC-3′ and 5′-CAAGCAGAAGACGGCATACGAGATJJJJJJGTGACTGGAGTTCAGACGTGTG-3′(where Js indicates the 6-mer index sequence for Illumina sequencing).
-
bioRxiv - Microbiology 2019Quote: 16S amplicon sequencing targeting the V3 and V4 variable regions of the 16S rRNA (341F: 5’-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAGCCTACGGGNGGCWGCAG-3’ and 805R: 5’- GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAGGACTACHVGGGTATCTAATC C-3’) was performed on the Illumina MiSeq platform (Illumina, California, USA) according to manufacturer’s guidelines and generated paired-end reads of 300bp in each direction ...
-
bioRxiv - Microbiology 2023Quote: ... The V3-V4 region of the 16S ribosomal RNA gene was amplified by PCR with universal bacterial primer sets (5’-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAGCCTACGGGNGGCWGCAG-3’ and 5’-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAGGACTACHVGGGTATCTAATCC-3’) and was sequenced using MiSeq Reagent kit v3 (600 cycle) (Illumina Inc., California, US). The sequence data were analyzed using QIIME2 (https://qiime2.org/ ...
-
bioRxiv - Molecular Biology 2022Quote: ... and reverse primers 5’-CAAGCAGAAGACGGCATACGAGAT-NNNNNNNN-GTGACTGGAGTTCAGACGTG-3’ (compatible to Illumina i7), with both containing 8N barcodes for multiplexing.
-
bioRxiv - Cancer Biology 2022Quote: ... All of the 3′ and 5′ flowcells were demultiplexed with bcl2fastq (Illumina). FASTQ files were processed with Cell Ranger v7.0.1 (10x Genomics) ...
-
bioRxiv - Microbiology 2021Quote: ... The library was diluted to a final concentration of 7 pM and 5% of PhiX DNA (Illumina, USA) was added ...
-
bioRxiv - Genomics 2023Quote: ... 3) carried no SNP or indel within 50 bp in their 5’ or 3’ flanking regions (Illumina probe design requirement); and 4 ...
-
bioRxiv - Genomics 2021Quote: Methyl-seq-captured libraries were sequenced using a Hiseq2500 device (Illumina), by applying paired-end 125bp reads ...
-
bioRxiv - Genomics 2021Quote: The TruSeq Methyl Capture Epic kit was a gift from Illumina. Sequencing libraries were prepared according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2021Quote: ... 7) DC3000 − A (Illumina only), 8 ...
-
bioRxiv - Cancer Biology 2024Quote: ... 5’-AATGATACGGCGACCACCGAGATCTACACTCTTT CCCTACACGACGCTCTTCCGATCTTGGAAC TGCTGTTTCCCACTT-3’ for bait 2 (Illumina prefix appended to downstream primer). The bait sequences for the IRX3 proximal promoter were ...
-
bioRxiv - Cancer Biology 2024Quote: ... 5’-AATGATACGGCGACCACCGAGATCTACACTCTTT CCCTACACGACGCTCTTCCGATCTTGCAGGA GCCCGAAGCA-3’ for bait 2 (Illumina prefix appended to downstream primer) and ...
-
bioRxiv - Neuroscience 2023Quote: ... using the combination of primer Ad1_noMX (5’ AATGATACGGCGACCACCGAGATCTACACTCGTCGGCAGCGTCAGATGTG 3’) and the Nextera Index Kit (Illumina) primer N701-N706 ...
-
bioRxiv - Microbiology 2019Quote: ... and the primers V3F - 5’-CCTACGGGNGGCWGCAG-3’ and V4R – 5’-GACTACHVGGGTATCTAATCC-3’ [28] with the addition of the appropriate Illumina Nextera XT overhang adapter sequences (Illumina, San Diego, CA, USA). Following purification using a magnetic bead capture kit (Ampure ...
-
bioRxiv - Genetics 2019Quote: ... The coding and splice-site regions of genes susceptible to hereditary arrhythmia and cardiomyopathies(10) were sequenced for probands II:3 and III-7 using Illumina HiSeq2500 Analyzer (Illumina, San Diego, CA, USA)(11) ...
-
bioRxiv - Genomics 2020Quote: ... using 5% PhiX without dark cycles (n = 11) or 10-20% PhiX with 7 dark cycles (protocol provided by Illumina, n = 49). A maximum of 12 samples were pooled in one sequencing run resulting in 19.05 million [17.05 – 21.72] single-end reads per sample on average (supplementary table 3).
-
bioRxiv - Genetics 2024Quote: ... libraries were prepared using EpiGnome™ Methyl-Seq reagents (Illumina, Inc, San Diego, CA), index-tagged for multiplexing ...
-
bioRxiv - Genetics 2023Quote: ... The Illumina TruSeq Methyl Capture EPIC library prep kit (Illumina, Santa Clara, CA, USA) was used following the manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2021Quote: ... Libraries from 7 independent SCL-exo experiments were sequenced on 7 lanes of a HiSeq 1500 (Illumina) by the GEH facility (Rennes ...
-
bioRxiv - Microbiology 2023Quote: ... 4 μl of the 3’-5’-adapter-ligated RNA was mixed with barcoded RT primers (Illumina) and cDNA synthesis was performed using SuperScript™ II Reverse Transcriptase (Invitrogen ...
-
bioRxiv - Genomics 2019Quote: ... and reverse transcribed using 25 pmol RT primer (5’-AATGATACGGCGACCACCGAGATCTACACGTTCAGAGTTCTACAGTCCGA-3’) for TRU-seq barcodes (RP1 primer, Illumina). A portion of the RT product was removed and used for trial amplifications to determine the optimal number of PCR cycles ...
-
bioRxiv - Bioengineering 2021Quote: ... Additional adapters at 5’-end (P5 and SP1) and 3’-end (P7 and SP2) were designed by Illumina for sequencing purpose ...
-
bioRxiv - Genomics 2021Quote: ... All DNA methylation data was generated using the TruSeq Methyl Capture EPIC kit (FC-151-1003, Illumina) according to manufacturer’s protocol [62] ...
-
bioRxiv - Molecular Biology 2020Quote: ... 10 ng of ssDNA was used as input for the Epicenter EpiGnome™ Methyl-Seq Kit (Illumina, EGMK81312 ...
-
bioRxiv - Molecular Biology 2022Quote: Equimolar amounts of libraries for Enzymatic Methyl-seq were first sequenced on the iSeq 100 instrument (Illumina) using paired-end sequencing of 2x151 to assess both library and pooling qualities ...
-
bioRxiv - Molecular Biology 2021Quote: ... The V4 region was amplified using 0.5 ng of DNA extracted from F and LL and the universal primer pairs 515F and 806R (underlined nucleotides in the following sequences) designed to contain from 5′ to 3′ ends the transposon Nextera’s sequences (Nextera DNA sample preparation guide, Illumina): 515F ...
-
bioRxiv - Cancer Biology 2022Quote: ... a third PCR was performed with a generic forward PCR primer (P5_generic, 5’ – AATGATACGGCGACCACCGAGATCTACAC – 3’) to retain the CB and UMI together with an RPI-x primer (Illumina) to complete the P7 end of the library and add a sample index (6 PCR cycles).Gene expression ...
-
bioRxiv - Cancer Biology 2022Quote: ... a third PCR was performed with a generic forward PCR primer (P5_generic, 5’ – AATGATACGGCGACCACCGAGATCTACAC – 3’) to retain the CB and UMI together with an RPI-x primer (Illumina) to complete the P7 end of the library and add a sample index (6 cycles) ...
-
bioRxiv - Cancer Biology 2021Quote: ... libraries were pooled equimolarly in two separate 5’ and 3’ pools and sequenced on a MiSeq Desktop Sequencer (Illumina).
-
bioRxiv - Cancer Biology 2022Quote: ... using primers DCF01 5’-CTTGTGGAAAGGACGAAACACCG-3’ and DCR03 5’-CCTAGGAACAGCGGTTTAAAAAAGC-3’ and subjected to single-end 75 bp (SE75) high-throughput sequencing using a NextSeq550 (Illumina).
-
bioRxiv - Developmental Biology 2020Quote: ... and two different mate-pair libraries (3 kb and 5 kb) were prepared with a Nextera Mate Pair Library Prep Kit (Illumina). Sequencing libraries were run on the Illumina Hiseq 2500 sequencer with a read length of 150 bp ...
-
bioRxiv - Biochemistry 2019Quote: ... double indexed libraries (Nextera XT indices) were prepared from recovered library DNA from rounds 3–5 and sequenced on a MiSeq platform (Illumina) using a v3 chip as single 151 cycle reads37 ...
-
A tale of two transcriptomic responses in agricultural pests via host defenses and viral replicationbioRxiv - Genomics 2020Quote: ... The rRNA-depleted samples were used for TruSeq Stranded RNA Sample Prep kit to produce 5′ to 3′ strand-specific cDNA libraries (Illumina). A TruSeq SBS sequencing kit version 3 (Illumina ...
-
bioRxiv - Microbiology 2023Quote: ... 3-5 µg of each sample was treated with Ribozero® rRNA Removal Kit according to the manufacturer’s instructions (Illumina, USA ...
-
bioRxiv - Microbiology 2023Quote: ... The RNA was dephosphorylated in 3’ and then phosphorylated in 5’ to generate cDNA libraries using the NebNext Small RNA Sample Prep kit with 3’ sRNA Adapter (Illumina) according to the manufacturer’s protocol with 12 cycles of PCR amplification in the last step followed by DNA purification with Monarch PCR DNA cleanup kit (NEB) ...
-
bioRxiv - Cell Biology 2023Quote: ... Illumina sequencing libraries were indexed with unique 5’ and 3’ barcode combinations (up to 384 cells) using the Nextera XT DNA library preparation kit (Illumina). Libraries were pooled and size-selected with 0.9X AmpPure XP beads ...
-
bioRxiv - Microbiology 2023Quote: ... The transposon-specific primer was designed to include (from 5’ to 3’): (i) the “P5” or “P7” flow-cell annealing sequence (Illumina), (ii ...
-
bioRxiv - Immunology 2023Quote: ... ADT and 3’ Gexp libraries were mixed at the ratio of 1:5 and sequenced on NovaSeq 6000 sequencer (Illumina) with a configuration of 28/8/0/91-bp for cell barcode ...
-
bioRxiv - Genetics 2020Quote: ... Libraries were prepared with the Accel-NGS Methyl-Seq DNA Library Kit from Illumina (Cat No. 30096, Swift) and the sequencing was performed at Novogene (Hongkong ...
-
bioRxiv - Immunology 2023Quote: ... 3 (Illumina).
-
bioRxiv - Microbiology 2020Quote: ... Shotgun metagenomic libraries were then constructed from a subset of these animals (LDC N = 15, DDC N = 7, CZMD N = 7) using the Nextera XT kit (Illumina, San Diego, CA USA) and sequenced on and Illumina HiSeq 3000 using a 150bp PE sequencing kit (Illumina).
-
bioRxiv - Microbiology 2021Quote: ... by 7 cycles PCR (16S Metagenomic Sequencing Library Preparation, Illumina). The amplicon libraries were purified using Agencourtusing the Agencourt AMPure XP system (Beckman) ...