Labshake search
Citations for Illumina :
1 - 50 of 1869 citations for 6 Chloro N 5 ethoxy 1H pyrazol 3 yl 3 nitropyridin 2 amine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2023Quote: ... for 1[h at 60°C and was subsequently PCR amplified using the primers 5′-AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTC-3′ and 5′-CAAGCAGAAGACGGCATACGAGATJJJJJJGTGACTGGAGTTCAGACGTGTG-3′(where Js indicates the 6-mer index sequence for Illumina sequencing).
-
bioRxiv - Physiology 2021Quote: ... 3’ and 5’ adaptors (Illumina) were ligated and the resulting product was reverse transcribed to generate cDNA by PCR ...
-
bioRxiv - Biochemistry 2024Quote: Forward Illumina Adapter: 5’-ACACTCTTTCCCTACACGACGCTCTTCCGATCTXXXX-3’ Reverse Illumina Adapter: 5’-GACTGGAGTTCAGACGTGTGCTCTTCCGATCTXXXX-3’ Next generation (Illumina) sequencing was performed by Azenta (Amplicon-EZ) ...
-
bioRxiv - Genomics 2020Quote: ... Each pool (2nM per library; Agilent SureSelect XT HS, n=6; Agilent SureSelect XT RNA Direct, n=6; Illumina TruSeq RNA Exome, n=5) was sequenced on one lane on the Illumina HiSeq 3000 platform in the Technology Center for Genomics and Bioinformatics at UCLA ...
-
bioRxiv - Cancer Biology 2024Quote: ... 5’-AATGATACGGCGACCACCGAGATCTACACTCTTT CCCTACACGACGCTCTTCCGATCTTGGAAC TGCTGTTTCCCACTT-3’ for bait 2 (Illumina prefix appended to downstream primer). The bait sequences for the IRX3 proximal promoter were ...
-
bioRxiv - Cancer Biology 2024Quote: ... 5’-AATGATACGGCGACCACCGAGATCTACACTCTTT CCCTACACGACGCTCTTCCGATCTTGCAGGA GCCCGAAGCA-3’ for bait 2 (Illumina prefix appended to downstream primer) and ...
-
Microplastic consumption induces inflammatory signatures in the colon and prolongs a viral arthritisbioRxiv - Immunology 2021Quote: ... for RNA extraction and 16S sequencing using V3-V4 region primers (Forward 5’- CCTAYGGGRBGCASCAG -3’ and Reverse 5’- GGACTACNNGGGTATCTAAT -3’. Sequencing was performed on an Illumina MiSeq platform.
-
bioRxiv - Developmental Biology 2022Quote: ... Extracted DNA was PCR-amplified (F 5’ – GTGCCTTCTCCGTCAGTCTC – 3’, R 5’ – GCAGGCACAAATCCAAGTTT – 3’, and subsequently subjected to next-generation sequencing in an Illumina MiSeq platform 116 ...
-
bioRxiv - Microbiology 2019Quote: ... the 16S rRNA sequences covering the V6-V7-V8 variable regions (5’ ACACTGACGACATGGTTCTACA 3’ and 5’ TACGGTAGCAGAGACTTGGTCT 3’) were PCR amplified and sequenced by Illumina MiSeq PE250 (paired-end) ...
-
bioRxiv - Microbiology 2020Quote: ... Microbiome communities in ligatures were characterized by sequencing of the 16S rRNA V1-V2 region using primers 8F 5’- AGAGTTTGATCMTGGCTCAG-3’ and 361R 5’- CYIACTGCTGCCTCCCGTAG-3’ which included the adapter for MiSeq sequencing (Illumina) and single end barcodes (4) ...
-
bioRxiv - Microbiology 2023Quote: The V3/V4 variable region of the 16S rRNA gene was amplified using primers 341F 5’CCTACGGGNGGCWGCAG′3 and 785R 5′GACTACHVGGGTATCTAATCC′3 (Klindworth et al., 2013 with Illumina Nextera XT overhang adapters for a dual-barcoding PCR library preparation approach ...
-
bioRxiv - Microbiology 2019Quote: 16S amplicon sequencing targeting the V3 and V4 variable regions of the 16S rRNA (341F: 5’-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAGCCTACGGGNGGCWGCAG-3’ and 805R: 5’- GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAGGACTACHVGGGTATCTAATC C-3’) was performed on the Illumina MiSeq platform (Illumina, California, USA) according to manufacturer’s guidelines and generated paired-end reads of 300bp in each direction ...
-
bioRxiv - Microbiology 2023Quote: ... The V3-V4 region of the 16S ribosomal RNA gene was amplified by PCR with universal bacterial primer sets (5’-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAGCCTACGGGNGGCWGCAG-3’ and 5’-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAGGACTACHVGGGTATCTAATCC-3’) and was sequenced using MiSeq Reagent kit v3 (600 cycle) (Illumina Inc., California, US). The sequence data were analyzed using QIIME2 (https://qiime2.org/ ...
-
bioRxiv - Microbiology 2023Quote: ... 2 μl of the v1.5 sRNA 3’ adapter (Illumina) was mixed with the 14 μl eluate of the previous step in a 200 μl nuclease-free ...
-
bioRxiv - Genomics 2019Quote: ... 1 μg DNA aliquots (n=3) were processed for 850K Infinium MethylationEPIC Array (Illumina) as previously described43 ...
-
bioRxiv - Genomics 2020Quote: RNA from a subset of human fetal (n = 3) and mouse (n = 8) cortex tissue samples was prepared with TruSeq Stranded mRNA Sample Prep Kit (Illumina) and subjected to 125bp paired-end sequencing using a HiSeq2500 (Illumina) ...
-
bioRxiv - Genomics 2023Quote: ... 3) carried no SNP or indel within 50 bp in their 5’ or 3’ flanking regions (Illumina probe design requirement); and 4 ...
-
bioRxiv - Immunology 2023Quote: ... 3 (Illumina).
-
bioRxiv - Molecular Biology 2022Quote: ... and reverse primers 5’-CAAGCAGAAGACGGCATACGAGAT-NNNNNNNN-GTGACTGGAGTTCAGACGTG-3’ (compatible to Illumina i7), with both containing 8N barcodes for multiplexing.
-
bioRxiv - Cancer Biology 2022Quote: ... All of the 3′ and 5′ flowcells were demultiplexed with bcl2fastq (Illumina). FASTQ files were processed with Cell Ranger v7.0.1 (10x Genomics) ...
-
bioRxiv - Microbiology 2019Quote: ... 5’-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAGGACTACHVGGGTATCTAATC C-3’) were sequenced using the Illumina MiSeq 2 × 300 bp platform with MiSeq Reagent Kit v3 (Illumina Co.) according to the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2022Quote: ... 1.5 μl of PCR 1 were used as template for PCR 2 (14 cycles) and used forward primers 5’-AATGATACGGCGACCACCGAGATCTACAC-NNNNNNNN-ACACTCTTTCCCTACACGAC-3’ (compatible to Illumina i5) and reverse primers 5’-CAAGCAGAAGACGGCATACGAGAT-NNNNNNNN-GTGACTGGAGTTCAGACGTG-3’ (compatible to Illumina i7) ...
-
bioRxiv - Cancer Biology 2019Quote: ... The 3’ preadenylated linker (NEBNext 3’SR adaptor for Illumina; /5rApp/AGA TCG GAA GAG CAC ACG TCT /3AmMO/ ...
-
bioRxiv - Cell Biology 2021Quote: ... The 3’ preadenylated linker (NEBNext 3’SR adaptor for Illumina; /5rApp/AGA TCG GAA GAG CAC ACG TCT /3AmMO/ ...
-
bioRxiv - Cell Biology 2024Quote: ... 3’ poly(A) tail and the 3’ adapter from Illumina were trimmed with the TrimGalore 0.06.10 tool (Babraham Bioinformatics ...
-
bioRxiv - Microbiology 2020Quote: ... 3’-adapter (Illumina) ligation was performed ...
-
bioRxiv - Immunology 2023Quote: ... 3’ adapters (Illumina Universal Adapter ...
-
bioRxiv - Microbiology 2020Quote: ... NGS sequencing was accomplished using MiSeq v.3 2×75 chemistry (Illumina). Raw sequencing files were demultiplexed using IlluminaBasecallsToFasq procedure from PICARD package and mapped to NC_055512.2 SARS-CoV-2 reference sequence with BwaAndMarkDuplicatesPipelineSpark procedure from GATK v.4.1.5.0 package (Broad Institute ...
-
bioRxiv - Microbiology 2023Quote: ... version 3 (2×300 bp read length; Illumina, San Diego, CA, USA).
-
bioRxiv - Microbiology 2019Quote: ... and the primers V3F - 5’-CCTACGGGNGGCWGCAG-3’ and V4R – 5’-GACTACHVGGGTATCTAATCC-3’ [28] with the addition of the appropriate Illumina Nextera XT overhang adapter sequences (Illumina, San Diego, CA, USA). Following purification using a magnetic bead capture kit (Ampure ...
-
bioRxiv - Microbiology 2023Quote: ... as well as 6 PCR negative control and 3 extraction negatives on a NovaSeq 6000 (Illumina), with 2 Gb requested per sample.
-
bioRxiv - Neuroscience 2023Quote: ... using the combination of primer Ad1_noMX (5’ AATGATACGGCGACCACCGAGATCTACACTCGTCGGCAGCGTCAGATGTG 3’) and the Nextera Index Kit (Illumina) primer N701-N706 ...
-
bioRxiv - Cancer Biology 2020Quote: The RNA-seq libraries (n=3 per experimental group) were prepared using the NEBNext Ultra II RNA library prep kit from Illumina (New England Biolabs Inc. ...
-
bioRxiv - Molecular Biology 2023Quote: ... RNA-seq libraries for yeast (n = 3 per tested condition) and neuroblastoma cells (n = 3 per tested condition) were prepared according to the TruSeq stranded mRNA protocol (Illumina) and 101-bp single-end reads produced on an Illumina NovaSeq 6000 instrument ...
-
bioRxiv - Microbiology 2021Quote: ... 3) DC3000 + A (Illumina only), 4 ...
-
bioRxiv - Immunology 2021Quote: ... Group 3 (North America, Illumina), Group 4 (French European ...
-
bioRxiv - Genetics 2019Quote: Genotype information was available for 21,001 NTR participants from 6 different genotyping arrays (Affymetrix 6.0 [N = 8,640], Perlegen-Affymetrix [N = 1,238], Illumina Human Quad Bead 660 [N = 1,439] ...
-
bioRxiv - Microbiology 2023Quote: ... 4 μl of the 3’-5’-adapter-ligated RNA was mixed with barcoded RT primers (Illumina) and cDNA synthesis was performed using SuperScript™ II Reverse Transcriptase (Invitrogen ...
-
bioRxiv - Genomics 2020Quote: ... Pre-capture libraries with less than 100 ng of double-stranded cDNA (n=5; PT0017_Qiagen_20ng_XTHS, PT0017_Covaris_20ng_XTHS, PT0017_Qiagen_20ng_Illumina, PT0017_Covaris_20ng_Illumina, Agilent_UHR_20ng_Illumina ...
-
bioRxiv - Microbiology 2020Quote: ... The MiSeq Reagent Kit v.3 (2 x 300 bp) (Illumina Inc., San Diego, California USA) was used for sequencing according to manufacturer’s recommendations.
-
bioRxiv - Molecular Biology 2023Quote: ... 2-3 ng of DNA was used as input for TruSeq ChIP Library Preparation Kit (Illumina) with following modifications ...
-
bioRxiv - Neuroscience 2023Quote: ... DNA methylation profiling for cohorts 2 and 3 were performed using the Infinium HumanMethylationEPIC BeadChip (Illumina). Sample processing steps and detailed methodology have been described previously [8,14] ...
-
bioRxiv - Microbiology 2023Quote: ... Small RNA Seq 3’ adapters (Illumina) were ligated using T4 RNA ligase (NEB ...
-
bioRxiv - Immunology 2023Quote: ... 3’ adapters (Illumina Universal Adapter, Illumina Multiplexing Adapter ...
-
bioRxiv - Genomics 2022Quote: ... n = 5 Illumina-sequenced datasets and n = 1 WGS of normal DNA (PBMC, Illumina sequencing). Variants were identified in all datasets using lofreq67 (without filtering ...
-
bioRxiv - Genomics 2019Quote: ... and reverse transcribed using 25 pmol RT primer (5’-AATGATACGGCGACCACCGAGATCTACACGTTCAGAGTTCTACAGTCCGA-3’) for TRU-seq barcodes (RP1 primer, Illumina). A portion of the RT product was removed and used for trial amplifications to determine the optimal number of PCR cycles ...
-
bioRxiv - Bioengineering 2021Quote: ... Additional adapters at 5’-end (P5 and SP1) and 3’-end (P7 and SP2) were designed by Illumina for sequencing purpose ...
-
bioRxiv - Neuroscience 2021Quote: ... and TruSeq SBS Kit 3-HS (Illumina) according to the manufacturer’s instructions.
-
bioRxiv - Genomics 2023Quote: ... and reverse oligos (3’ P7 Illumina adapter). The GRB2-SH3 bPCA library was single-indexed using a constant forward oligo (3’ P7 Illumina adapter ...
-
bioRxiv - Genomics 2023Quote: ... RNA was extracted from similar pooled-samples (N = 3) using the ZYMO (Irvine, CA, USA) direct-zol miniprep kit (Cat. # R2050) and sequenced using NovaSeq (Illumina, San Diego, CA, USA) paired-end (150 bp ...