Labshake search
Citations for Illumina :
1 - 50 of 1464 citations for 6 BROMO 2 METHYL QUINOLINE 4 CARBOXYLIC ACID METHYL ESTER since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genomics 2021Quote: Methyl-seq-captured libraries were sequenced using a Hiseq2500 device (Illumina), by applying paired-end 125bp reads ...
-
bioRxiv - Genomics 2021Quote: The TruSeq Methyl Capture Epic kit was a gift from Illumina. Sequencing libraries were prepared according to the manufacturer’s instructions ...
-
bioRxiv - Systems Biology 2024Quote: ... according to the Ovation RRBS Methyl-Seq System 1-16 protocol for the first read and the Read 2 primer (Illumina) for the second read ...
-
bioRxiv - Genetics 2024Quote: ... libraries were prepared using EpiGnome™ Methyl-Seq reagents (Illumina, Inc, San Diego, CA), index-tagged for multiplexing ...
-
bioRxiv - Genetics 2023Quote: ... The Illumina TruSeq Methyl Capture EPIC library prep kit (Illumina, Santa Clara, CA, USA) was used following the manufacturer’s instructions ...
-
bioRxiv - Genomics 2021Quote: ... All DNA methylation data was generated using the TruSeq Methyl Capture EPIC kit (FC-151-1003, Illumina) according to manufacturer’s protocol [62] ...
-
bioRxiv - Molecular Biology 2020Quote: ... 10 ng of ssDNA was used as input for the Epicenter EpiGnome™ Methyl-Seq Kit (Illumina, EGMK81312 ...
-
bioRxiv - Molecular Biology 2022Quote: Equimolar amounts of libraries for Enzymatic Methyl-seq were first sequenced on the iSeq 100 instrument (Illumina) using paired-end sequencing of 2x151 to assess both library and pooling qualities ...
-
bioRxiv - Genetics 2020Quote: ... Libraries were prepared with the Accel-NGS Methyl-Seq DNA Library Kit from Illumina (Cat No. 30096, Swift) and the sequencing was performed at Novogene (Hongkong ...
-
bioRxiv - Genetics 2020Quote: Whole genome bisulfite sequencing libraries were generated with the Accel-NGS Methyl-seq DNA Library Kit (Swift Biosciences) and sequenced on a HiSeq X10 (Illumina) in 150bp PE mode with PhiX spike-in to counteract low sequence diversity ...
-
bioRxiv - Cancer Biology 2022Quote: ... resistant and P12 cells of cell lines #3 and #9 was performed at the Genomics and Proteomics Core Facility of the German Cancer Research Center (GPCF DKFZ, Heidelberg) using the TruSeq DNA PCR-free Methyl protocol (Illumina) for library preparation ...
-
bioRxiv - Genomics 2023Quote: ... xGen Methyl-Seq Library kit was purchased from Integrated DNA Technologies and Nextera XT library prep kit was from Illumina, Inc.
-
bioRxiv - Cancer Biology 2020Quote: ... Samples were cleaned using Sample Purification Beads from the TruSeq Methyl Capture EPIC LT Library Prep Kit (Illumina, #FC-151-1002) according to the manufacturer’s instructions with modifications ...
-
bioRxiv - Genomics 2022Quote: ... Whole genome bisulfite sequencing libraries were prepared (according to Accel-NGS Methyl-Seq DNA library Kit for Illumina protocol, Swift Biosciences) and sequenced in 150 bp paired-end reads by Novogene company.
-
bioRxiv - Cancer Biology 2022Quote: ... Post-ligation cleanup proceeded according to Illumina’s instructions with 110 µL Sample Purification Mix from the TruSeq Methyl Capture EPIC LT Library Prep Kit (Illumina catalog # FC-151-1002). After purification ...
-
bioRxiv - Microbiology 2023Quote: ... The prepared library was sequenced using a MiSeq sequencing system with a V3 reagent kit (300 × 2 bp; Illumina, 4–6 samples). Lake Biwa viral contigs/genomes (LBVs ...
-
bioRxiv - Immunology 2019Quote: ... The indexed samples were multiplexed per 4 or 6 and sequenced on a HiSeq2500 sequencer (Illumina) to produce single-ends 65 bases reads ...
-
bioRxiv - Cancer Biology 2019Quote: ... Libraries were 6-plexed and sequenced with 2×100bp reads on a HiSeq-4000 (Illumina). The data were mapped using BWA ...
-
bioRxiv - Physiology 2022Quote: ... Samples were sequenced on the HiSeq 2500 (Figure 2) or NovaSeq 6000 (Figure 6; Illumina) using a 2×100 kit to a read depth >45 million reads/sample ...
-
bioRxiv - Molecular Biology 2023Quote: ... 2 or 4 nM concentration and run on NextSeq 550 sequencer (Illumina) with NextSeq 500/550 High Output v2.5 (75 cycles PE ...
-
bioRxiv - Cancer Biology 2020Quote: ... in paired-end mode on Illumina (2×101 bp) using TrueSeq DNA exome kit (v.6) (Illumina Inc.). Paired-end reads were aligned to the human reference genome sequence GRCh38 using BWA–MEM (V0.715-r1140 ...
-
bioRxiv - Genomics 2019Quote: ... RNAseq libraries were pooled and sequenced via single end 50 bp reads on a HiSeq 2500 (4 libraries per lane) or HiSeq 4000 (6 libraries per lane)(Illumina).
-
bioRxiv - Cell Biology 2019Quote: ... Libraries were run over 4 lanes (2 × 100 bp) on a HiSeq 2500 (Illumina Inc.) resulting in an average of 34.4 million reads per sample.
-
bioRxiv - Physiology 2020Quote: ... Libraries were run over 4 lanes (2 × 100 bp) on a HiSeq 2500 (Illumina Inc.) resulting in an average of 34.4 million reads per sample ...
-
bioRxiv - Molecular Biology 2020Quote: ... Small RNA-seq libraries for 2–4 biological samples were sequenced together using a NextSeq 500 (Illumina) to obtain 75 nt ...
-
bioRxiv - Developmental Biology 2022Quote: ... 75bp single end sequencing was carried out on 4-6 libraries / genotype using Illumina NextSeq500 High output mode and v2.5 chemistry (Illumina Protocol 15046563 v02, Mar 2016) to collect >25M reads per sample.
-
bioRxiv - Genomics 2019Quote: ... and 800 bp) and four mate-pair libraries (2, 6, 10, and 20 Kb) following the standard protocols provided by Illumina (San Diego, USA). Subsequently ...
-
bioRxiv - Microbiology 2019Quote: ... RNA from cultures grown on PM-4-HBA and PM-syringic acid was processed and sequenced at the University of Wisconsin-Madison Biotechnology Center (Illumina HiSeq2500, 1×100 bp, single end). RNA from cultures grown on PM-succinate was processed and sequenced at the U.S ...
-
bioRxiv - Systems Biology 2024Quote: ... in two growth media conditions (CMAF and Basal)—were profiled by Illumina BeadArrays (mouse WG-6 v2, Illumina). Poor quality profiles were removed ...
-
bioRxiv - Systems Biology 2024Quote: ... Illumina BeadArrays (mouse WG-6, Illumina) were used to profile the transcriptome of 33 independent EpiSC samples ...
-
bioRxiv - Microbiology 2021Quote: ... Libraries were sequenced using 2 x 150 nt paired-end sequencing runs (4 lanes on separate runs) on NextSeq Genome Sequencer (Illumina) with a NextSeq 500/550 High Output Kit v2.5 at Core Facility for Scientific Research – University of Sao Paulo (CEFAP-USP).
-
bioRxiv - Genomics 2023Quote: ... all samples were pooled at 4 nm concentration and paired-end [300bp (2 × 151bp)] sequenced in MiSeq platform (Illumina, USA).
-
bioRxiv - Microbiology 2021Quote: ... 6) merged triplicates for DC3000 − (Illumina only), 7 ...
-
bioRxiv - Cancer Biology 2020Quote: ... and hybridized to BeadChip Array MouseWG-6 (Illumina). Bead chips were scanned with an Illumina BeadArray Reader ...
-
bioRxiv - Systems Biology 2024Quote: ... and hybridized on mouseWG-6 v2 BeadArrays (Illumina). Slides were scanned using an iScan (Illumina SY-101- 1001 ...
-
bioRxiv - Genomics 2022Quote: ... spun at 300G for 12 min at 4 ºC and resuspended in 20 uL transposition mix: 1X TD buffer and 2 uL of TDE1 (Illumina #FC-121-1030), 0.01% Digitonin in DMSO ...
-
bioRxiv - Genomics 2022Quote: ... and DRB3, 4, 5 (exon 2) genes with Fluidigm Access Array (Fluidigm, Singapore) and sequenced on an Illumina MiSeq sequencer (Illumina, San Diego, USA). HLA alleles and genotypes are called using the Omixon HLA Explore (version 2.0.0 ...
-
bioRxiv - Neuroscience 2020Quote: ... and hybridized to MouseWG-6 v2.0 Expression BeadChips (Illumina). Raw data were preprocessed with quantile normalization in R/Bioconductor using the package beadarray ...
-
bioRxiv - Genomics 2020Quote: ... 64 RNA-Seq libraries (4 time points x 4 tissues x 4 biological replicates) were prepared using the TruSeq RNA Sample Preparation Kit (Illumina). Libraries were sequenced on Illumina Nova-Seq 6000 sequencing platform at the Australian Genome Research Facility (AGRF ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... The library was pooled with other samples at equimolar concentrations and sequenced at 4 nM as single lanes on Illumina NovaSeq 6000 S4 platform (2×150; Illumina Inc., San Diego, CA). The library for long-read data was prepared using the Nanopore ligation kit ...
-
bioRxiv - Genomics 2020Quote: ... Each pool (2nM per library; Agilent SureSelect XT HS, n=6; Agilent SureSelect XT RNA Direct, n=6; Illumina TruSeq RNA Exome, n=5) was sequenced on one lane on the Illumina HiSeq 3000 platform in the Technology Center for Genomics and Bioinformatics at UCLA ...
-
bioRxiv - Plant Biology 2022Quote: ... 2 (Illumina) were used for construction of complementary DNA libraries and the complementary DNA libraries were sequenced on a NextSeq 500 system (Illumina) ...
-
bioRxiv - Developmental Biology 2023Quote: ... 2 (Illumina) and the HiSeq Rapid SBS Kit v2-HS (Illumina ...
-
bioRxiv - Neuroscience 2023Quote: ... 2 (Illumina) for the sequencing.
-
bioRxiv - Immunology 2023Quote: ... 2 (Illumina) was the primer source ...
-
bioRxiv - Genetics 2020Quote: ... and the libraries were sequenced in pools of 6 (Illumina HiSeq2500 high output flow-cell ...
-
bioRxiv - Microbiology 2021Quote: ... 4) DC3000 + B (Illumina only), 5 ...
-
bioRxiv - Immunology 2021Quote: ... Group 4 (French European, Illumina), Group 5 (North American ...
-
bioRxiv - Molecular Biology 2023Quote: ... Index i7 (6 pb barcode) was read with primer HP8 (Illumina).
-
bioRxiv - Evolutionary Biology 2023Quote: ... 6-digit index primers (Illumina RNA PCR Index Primers RPI1-RPI28) were used instead of 10-digit index primers suggested by the LM-Seq protocol ...