Labshake search
Citations for GE Life Sciences :
1 - 50 of 3567 citations for 7 CHLORO 3 PHENYL PYRAZOLO 1 5 A PYRIMIDINE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2019Quote: ... Phenyl-Superose HR5/5 and Superose 12 HR10/30 were from GE Healthcare.
-
bioRxiv - Biochemistry 2023Quote: ... hydrophobic interaction chromatography (HIC) on a 5-ml Phenyl-Sepharose column (GE Healthcare), and gel filtration on a Superdex 75 16/600 (GE Healthcare) ...
-
bioRxiv - Biophysics 2022Quote: ... hydrophobic chromatography on a phenyl-sepharose column (HiTrap Phenyl HP, GE Healthcare) and size exclusion chromatography on an analytical HiLoad 16/60 Superdex 75 (HiLoad 16/600 Superdex 75 pg ...
-
bioRxiv - Microbiology 2020Quote: ... The cell free supernatant was loaded onto a 5 ml HiTrap Phenyl FF (GE Healthcare) and protein was eluted by using a linear reverse gradient to 100 mM NaCl over 90 min at a flow rate of 2.5 ml/min ...
-
bioRxiv - Biophysics 2021Quote: ... 50 mM Bis-Tris pH 7) and further purified on a HiPrep Phenyl FF 16/10 (High Sub) hydrophobic interaction chromatography (HIC) column (GE Healthcare) and eluted against buffer D (50 mM Bis-Tris pH 7) ...
-
bioRxiv - Neuroscience 2022Quote: ... 50 mM Bis-Tris pH 7) and further purified on a HiPrep Phenyl FF 16/10 (High Sub) hydrophobic interaction chromatography (HIC) column (GE Healthcare) and eluted against buffer D (50 mM Bis-Tris pH 7) ...
-
bioRxiv - Biochemistry 2020Quote: ... for 1-7 days before acquiring radiograms using Typhoon 5 Imager (GE Healthcare). Densitometry was carried out using ImageJ53 ...
-
bioRxiv - Plant Biology 2023Quote: ... Recombinant CaM was purified using phenyl-sepharose resin (Phenyl Sepharose® 6 Fast Flow, GE Healthcare Inc.) as described (Bender et al. ...
-
bioRxiv - Biochemistry 2021Quote: ... followed by hydrophobic interaction chromatography (HIC) using a 5 mL HiTrap Phenyl FF (HS) column (GE Healthcare). For the ion exchange procedure ...
-
bioRxiv - Cell Biology 2020Quote: ... was amplified by PCR using the primers (5’-GGTTCCGCGTGGATCCATGTCTCATGCAGCCGAGCCA-3’ and 5’-GGAATTCCGGGGATCCTCAGGACTCCTCTTCAATGCTGA-3’) and cloned into BamHI site of pGEX-4T-1 expression vector (GE Healthcare) using In-Fusion HD Cloning System (Clontech) ...
-
Improved Activity and Kinetics of Endoglucanase Biofuel Enzyme with Addition of an AzoTAB SurfactantbioRxiv - Bioengineering 2023Quote: ... HiTrap Phenyl HP (GE Healthcare, 17-1351-01) hydrophobic column was used to obtain β-glucosidase fraction ...
-
bioRxiv - Biochemistry 2022Quote: ... the affinity-purified Pvs25 protein was applied to hydrophobic interaction chromatography (HIC) (HiTrap Phenyl HP; 5 mL resin, GE Healthcare) In detail ...
-
bioRxiv - Microbiology 2019Quote: ... Proteins were loaded into 7 cm IPG Strips 3-10 (GE Healthcare) by overnight passive rehydration ...
-
bioRxiv - Microbiology 2019Quote: ... IEF was performed using 24 cm 3–7 NL Immobiline DryStrip (GE Healthcare) in an IPGphor unit (GE Healthcare ...
-
bioRxiv - Immunology 2019Quote: ... placed on Ficoll-Paque Plus (ratio 7:3) (GE Healthcare Life Sciences, 17144003), and centrifuged for 20 min at 1800 rpm at room temperature ...
-
bioRxiv - Microbiology 2021Quote: ... followed by another purification using Phenyl Sepharose (GE Healthcare, USA).
-
bioRxiv - Biochemistry 2022Quote: ... and then immobilized in 7 cm IPG strips (pH 3-10 : 70×3×0.5 mm) and a linear gradient (NL) (GE Healthcare Immobiline™ Dry Strip IPG ...
-
bioRxiv - Animal Behavior and Cognition 2020Quote: ... CG42797EcoRI_F: 5’-CCGgaattcATGGAGCCACCAGCT-3’ and CG42797XhoI_R: 5’-TAGAGGTACCctcgagCTACTCAATGCCGAACGTGTTG-3’ and cloned by enzymatic digestion into a pGEX6P1(GE Healthcare).
-
bioRxiv - Animal Behavior and Cognition 2020Quote: ... CG42797EcoRI WWI_F: 5’-ccgGAATTCCCACCATTGCCGCCTG-3’ CG42797XhoI WWII_R: 5’-ccgCTCGAGTCAACGAGGATCCATGAA-3’ and cloned by enzymatic digestion into a pGEX6P1(GE Healthcare).
-
bioRxiv - Animal Behavior and Cognition 2020Quote: ... CG42797EcoRI_F: 5’-CCGgaattcATGGAGCCACCAGCT-3’ and CG42797XhoI_Nterm_R: 5’-CCGctcgagTCATTCGCTGGGCTGC-3’ and cloned by enzymatic digestion into a pGEX6P1(GE Healthcare).
-
bioRxiv - Immunology 2021Quote: ... and hydrophobic interactions with a HiTrap Phenyl HP column (GE healthcare. The individual TCR δ- and γ-chains of the VD1G9 TCR were ordered (IDT) ...
-
bioRxiv - Cancer Biology 2022Quote: Custom siRNAs targeting 5’-CACCAUGAGUGGCAGUCAG-3’ 33 for FRA1 and 5′-GUUCACUGCUGGCCUAUAA-3’ 34 for FLI1 were ordered from GE Healthcare Dharmacon ...
-
bioRxiv - Biophysics 2022Quote: ... The protein solution was applied to a Phenyl-sepharose HP (GE Healthcare) column equilibrated with 20 mM MES-NaOH pH 6.0 ...
-
bioRxiv - Molecular Biology 2022Quote: ... CaM was initially purified by affinity to phenyl sepharose (GE Life Sciences) in the presence of 5 mM CaCl2 ...
-
bioRxiv - Immunology 2023Quote: ... Phenyl-Sepharose Fast Flow (low sub) (GE Healthcare Life Sciences, Uppsala, Sweden) was added and supernatants gently mixed in 4°C for 1.5 h ...
-
bioRxiv - Biophysics 2022Quote: ... the solution was loaded onto a 10 ml Phenyl-sepharose HP (GE Healthcare) column equilibrated with 20 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Biophysics 2022Quote: ... the solution was loaded onto a 10 ml Phenyl-sepharose HP (GE Healthcare) column equilibrated with 20 mM MOPS-NaOH pH 6.7 ...
-
bioRxiv - Cancer Biology 2023Quote: ... The shRNA constructs targeting mouse ezrin (5’-ATTTCCTTGTTATAATCTCCG-3’) in a pLKO-puro.1 vector from GE Healthcare and described in27 ...
-
bioRxiv - Immunology 2020Quote: ... Dilution series of TBK1 or IRF-3 (1.25, 2.5, 5, 10, 20 μM) in 1× HBS-EP+ buffer (GE Healthcare) were injected over the sensor chip at a flow rate of 30 μL/min ...
-
Deletion or inhibition of PTPRO mitigates diet-induced hepatic steatosis and inflammation in obesitybioRxiv - Immunology 2022Quote: ... Isoelectric focusing (IEF) was performed using 7-cm Immobiline DryStrips (pH 3–11 nonlinear) (GE Healthcare Life Sciences, USA) in an Ethan IPGphor II Isoelectric Focusing System (GE Healthcare Life Sciences ...
-
bioRxiv - Biochemistry 2019Quote: ... protein supernatant was bound to a phenyl sepharose column (High Load FF 16/10, GE Healthcare). The column was washed with buffer C and protein eluted with 30% ethanol in water ...
-
bioRxiv - Biochemistry 2020Quote: ... 1.5 M (NH4)2SO4) and was loaded on a 50 ml Phenyl Sepharose column (GE Healthcare). After one column volume wash step the tRNAs were eluted with a linear gradient of Phe-sepharose B buffer (20 mM NaOAc ...
-
bioRxiv - Biophysics 2022Quote: ... A second purification step was performed by hydrophobic interaction chromatography (HiTrap Phenyl HP column, GE Healthcare), where OCP was eluted in 40 mM Tris-HCl pH 8 ...
-
bioRxiv - Plant Biology 2022Quote: ... The sample was finally subjected to hydrophobic interaction chromatography using a phenyl Sepharose column (GE Healthcare) equilibrated in buffer A (50 mM Tris pH 7.5 ...
-
bioRxiv - Biochemistry 2021Quote: ... Proteins were further purified using an AKTA FPLC system with HiTrap-Phenyl-HP column (GE Healthcare) and Superdex 200 size exclusion chromatography ...
-
bioRxiv - Molecular Biology 2021Quote: ... StuI was further purified by hydrophobic interaction chromatography in a HiTrap Phenyl HP column (GE Healthcare). The ion-exchange chromatography were performed as a linear gradient from 20 mM Tris ...
-
bioRxiv - Cancer Biology 2024Quote: ... for 3-5 minutes and visualized using Amersham Imager 600 (GE Healthcare).
-
bioRxiv - Cell Biology 2023Quote: ... by capillarity and membranes were hybridized with a 32P-labelled oligonucleotide probe (23S.1, 5’- GATTGCTCGAATGCCCAAAG-3’) using Rapid-hyb buffer (GE Healthcare). Radioactive membranes were exposed to Phosphorimaging screens and analysed using a Typhoon Tryo (GE Healthcare).
-
bioRxiv - Microbiology 2020Quote: ... the supernatant was loaded on a HiLoad 16/10 Phenyl Sepharose HP (GE Healthcare® Life Sciences) column ...
-
bioRxiv - Biochemistry 2020Quote: ... 5’-FAM-UGUUCUUCUGGAAGUCCAGTT-3’) was separated by gel electrophoresis (20% polyacrylamide gel containing 7 M Urea) and visualized with a Typhoon FLA9500 (GE Healthcare).
-
bioRxiv - Microbiology 2019Quote: ... were loaded on 7-cm long immobilized pH gradient (IPG) strips with non-linear (NL) 3-10 pH gradient (GE Healthcare). Isoelectric focusing was carried out in Multiphor II electrophoresis system (GE Healthcare ...
-
bioRxiv - Neuroscience 2021Quote: ... Blots were washed 3–5 times and incubated with a 1:5000 dilution of horseradish peroxidase-conjugated goat anti-rabbit antibody (GE Healthcare, UK) for one hour ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: The resulting supernatant was checked for activity prior to being applied to a 75mL Phenyl Sepharose (GE Healthcare) resin equilibrated in Buffer B (1 M ammonium sulfate ...
-
bioRxiv - Cell Biology 2021Quote: ... and mCherry (5% laser power, 0,05 exposure) were recorded at 7 minutes intervals and data were analyzed using SoftWoRx (GE Healthcare). The time from nuclear envelope breakdown (NEBD ...
-
bioRxiv - Microbiology 2020Quote: ... 7 cm strips (GE Healthcare).
-
bioRxiv - Cell Biology 2020Quote: ... a total of 1×104 RAW 264.7 (ATCC) cells were seeded per well on 24-well plates in 500 μl αMEM containing 5% FCS (Hyclone, GE Healthcare), 1% penicillin-streptomycin (Gibco ...
-
bioRxiv - Microbiology 2021Quote: ... The cDNA was labelled individually with both Cy-3 and Cy-5 dyes (GE Healthcare) using Superscript III reverse transcriptase (Invitrogen) ...
-
bioRxiv - Microbiology 2021Quote: ... (7) Superdex 75 resin (GE Healthcare) chromatography using an isocratic elution in Tris buffer B and (8 ...
-
Intra-mitochondrial proteostasis is directly coupled to alpha-synuclein and Amyloid β 1-42 pathologybioRxiv - Neuroscience 2020Quote: ... Alpha-synuclein was then further purified on a HiPrep Phenyl FF 16/10 (High Sub) hydrophobic interaction column (GE Healthcare) (76) ...
-
bioRxiv - Biochemistry 2020Quote: ... were pooled and supplemented with ammonium sulfate to a final concentration of 1.5M and loaded on a 5ml pre-packed HiTrap Phenyl HP column (GE Healthcare) equilibrated with buffer A (100mM Tris pH 7.3 ...