Labshake search
Citations for GE Life Sciences :
1 - 50 of 2760 citations for 17 Hydroxyprogesterone ELISA Kit 5 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... 5 mM DTT) with a PD10 column (17-0850-01, GE Healthcare) and applied to a Superdex 75 Increase 10/300 GL(GE Healthcare ...
-
bioRxiv - Biochemistry 2019Quote: ... A HiTrap SP HP column (5 ml) (17-1151-01, GE Healthcare) was equilibrated with buffer A containing 0.1 M KCl prior to loading the clarified lysates ...
-
bioRxiv - Cell Biology 2023Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-040901) charged with 100 mM CoCl2 for 1 hour ...
-
bioRxiv - Molecular Biology 2021Quote: ... G sepharose (17-1279-03 and 17-0618-05, GE Healthcare) at 4°C on a nutator ...
-
bioRxiv - Molecular Biology 2021Quote: ... G sepharose (17-1279-03 and 17-0618-05, GE Healthcare) at 4°C with agitation ...
-
bioRxiv - Genomics 2021Quote: ... G sepharose (17-1279-03 and 17-0618-05, GE Healthcare) at 4°C with agitation ...
-
bioRxiv - Immunology 2020Quote: ... clarified by centrifugation and subsequently incubated with Peptide M(Invivogen)/Protein G-coupled sepharose beads (Invivogen, catalog# gel-pdm-5; GE healthcare, 17-0618-05) overnight at 4°C ...
-
bioRxiv - Immunology 2020Quote: ... Protein was column-purified on Nap-5 columns (GE healthcare, Chicago, IL; #17-0853-01) and immunoprecipitated on Sephadex protein A/G beads (Sigma Aldrich ...
-
bioRxiv - Biochemistry 2021Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) charged with 100 mM CoCl2 for 1 hour ...
-
bioRxiv - Biochemistry 2021Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) that had been equilibrated with 100 mM CoCl2 for 1 hour ...
-
bioRxiv - Biochemistry 2021Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) charged with 100 mM CoCl2 for 1 hour ...
-
bioRxiv - Biochemistry 2023Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) that had been equilibrated with 100 mM CoCl2 for 1 hour ...
-
bioRxiv - Biochemistry 2023Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) that had been equilibrated with 100 mM CoCl2 for 1 hour ...
-
bioRxiv - Biochemistry 2023Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) charged with 100 mM CoCl2 for 1 hour ...
-
bioRxiv - Biochemistry 2023Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) charged with 100 mM CoCl2 for 1 hour ...
-
bioRxiv - Cell Biology 2023Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) charged with 100 mM CoCl2 for 1 hour ...
-
bioRxiv - Cell Biology 2023Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) that had been equilibrated with 100 mM CoCl2 for 1 hour ...
-
bioRxiv - Biochemistry 2023Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) charged with 100 mM CoCl2 for 2 hrs ...
-
bioRxiv - Biochemistry 2023Quote: ... Supernatant was circulated over 5 mL HiTrap chelating column (GE Healthcare, Cat# 17-0409-01) that was pre-incubated with 100 mM CoCl2 for 10 minutes ...
-
bioRxiv - Biochemistry 2023Quote: ... Lysate was circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) loaded with CoCl2 ...
-
bioRxiv - Cell Biology 2021Quote: ... 1 mM TCEP and loaded to 5 ml HiTrap SP HP (GE Healthcare, 17-1152-01). After extensive washing ...
-
bioRxiv - Biochemistry 2023Quote: ... Supernatant was then circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) that was inoculated with 100mM CoCl2 for ten minutes ...
-
bioRxiv - Biochemistry 2020Quote: ... The filtered sample was applied to a 5 mL HisTrap HP column (GE Healthcare, #17-5248-02), pre-equilibrated with Buffer N and 40 mM imidazole using a peristaltic pump ...
-
bioRxiv - Biochemistry 2021Quote: ... the supernatant was loaded onto a HisTrap column (5 mL, cat. No. 17-5248-01, GE Healthcare) pre-equilibrated with lysis buffer ...
-
bioRxiv - Immunology 2021Quote: ... IFN-α2 protein was column-purified using Nap-5 columns (GE Healthcare, Chicago, IL; #17-0853-01), incubated with 2.5ul serum ...
-
bioRxiv - Cell Biology 2023Quote: ... Cleared lysates were incubated with 70⍰μl of streptavidin beads (5⍰ml; 17-5113-01, GE Healthcare) at 4° for 3⍰h ...
-
bioRxiv - Neuroscience 2023Quote: ... the dialyzed protein was applied to a 5 ml HisTrapTM column (GE Life Sciences, 17-5248-02), equilibrated with dialysis buffer ...
-
bioRxiv - Biochemistry 2023Quote: ... cell lysate was circulated over a 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) charged CoCl2 ...
-
bioRxiv - Neuroscience 2023Quote: ... the dialyzed protein was applied to a 5 ml HisTrapTM column (GE Life Sciences, 17-5248-02), equilibrated with dialysis buffer ...
-
bioRxiv - Immunology 2023Quote: ... the cortex was homogenized and resuspended with 5 ml 70% Percoll Plus (GE Healthcare, 17-5445-02) and 5 ml 37% Percoll Plus placed on top ...
-
bioRxiv - Molecular Biology 2023Quote: ... was purchased from VWR (GE Healthcare 17-5113-01). OMIX C18 tips (100 µL ...
-
bioRxiv - Microbiology 2020Quote: ... The fractions containing proteins were loaded onto the HiTrap Desalting 5 x 5 ml (Sephadex G-25 S) (GE Healthcare, Code#: 17-1408-01) with a running condition of 50 mM Tris (pH 8.0) ...
-
bioRxiv - Neuroscience 2020Quote: ... Sepharose (GE Healthcare, 17-0618-01) for 2 h at 4°C rotating ...
-
bioRxiv - Molecular Biology 2019Quote: Clarified extracts containing hexahistidine fusion proteins were passed through a 5 mL Ni-Sepharose (GE Healthcare #17-5268-01) packed column at 0.5 mL/min using an ÄKTAprime Plus chromatography system ...
-
bioRxiv - Molecular Biology 2019Quote: ... Clarified extracts containing GST fusion proteins were passed through a 5 mL GSTrap column (GE Healthcare #17-5131-02) at 0.1 mL/min using an ÄKTAprime Plus chromatography system (GE Healthcare) ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was applied to a 5-ml His-Trap HF column charged with NiCl2 (GE Healthcare, 17-5248-02). GFP-NONO_WT or GFP-NONO_ΔRRM1 was eluted at room temperature with an imidazole gradient (25-500 mM ...
-
bioRxiv - Molecular Biology 2022Quote: ... Cleared lysates were incubated with 5 ml bed volume Glutathione Sepharose 4B resin (GE Healthcare, cat. No. 17-0756-05) for 1 hour ...
-
bioRxiv - Molecular Biology 2024Quote: ... 30 μl of a protein A/G sepharose mixture (GE Healthcare; #17-0780-01 and #17-0618-01), pre-equilibrated in ChIP dilution buffer was added to the lysates and incubation continued for 2 h at 4°C ...
-
bioRxiv - Biophysics 2019Quote: ... Q column (GE Healthcare, 17-5156-01) was used to purify the protein samples and size-exclusion chromatography Superdex 75 (GE Healthcare ...
-
bioRxiv - Plant Biology 2020Quote: ... Percoll® (#17-0891-02, GE Healthcare) gradients were prepared as follows ...
-
bioRxiv - Cell Biology 2020Quote: ... and PD10 (GE Healthcare, 17-0851-01) exchange columns ...
-
bioRxiv - Immunology 2020Quote: Ficoll-Hypaque (GE Healthcare, 17-1440-03) and cultured (2×106 cells/mL ...
-
bioRxiv - Biochemistry 2023Quote: ... the percoll (#17-0891-01, GE healthcare) gradient was prepared using ADS buffer ...
-
bioRxiv - Cell Biology 2019Quote: ... Lysate was cleared with centrifugation and loaded to HisTrap FF crude 5 ml Ni-NTA column (GE healthcare, #17-5286-01). Column was washed with 10 column volume of lysis buffer ...
-
bioRxiv - Cell Biology 2023Quote: ... Labelling reactions proceeded for 40 mins at 4°C and the excess dye was removed using NAP-5 desalting columns (17-0853-01, GE Healthcare). Nanobodies to be used for confocal microscopy were labelled with Alexa488 (Thermo Fisher ...
-
bioRxiv - Bioengineering 2021Quote: ... Protein G-coupled sepharose (#17–0618–01) and Protein A-coupled sepharose (#17–5138–01) beads were from GE Healthcare and the protease inhibitor cocktail was from Sigma.
-
bioRxiv - Cell Biology 2021Quote: ... Protein G–Sepharose (GE Healthcare, 17-0618-01). Dynabeads Protein G (Invitrogen ...
-
bioRxiv - Cell Biology 2021Quote: ... SP Sepharose beads (#17-0729-01, GE Healthcare) were equilibrated with the lysis buffer and the cleared lysate obtained is mixed with the beads and batch bound for 1 h ...
-
bioRxiv - Neuroscience 2022Quote: ... and 23% Percoll (GE Healthcare, #17-0891-01) layers (6 mL/layer ...
-
bioRxiv - Cell Biology 2020Quote: ... Ficoll PM400 (GE Healthcare, Cat. #17-0310-10) or polyethylene glycol 4000 (PEG ...