Labshake search
Citations for Sciex :
1 - 50 of 54 citations for NGS ChIP Seq kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2020Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 μm x 0.4 mm ChromXP C18-CL chip, 3 μm, 120 Å, SCIEX) and washed at 2 μl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Biochemistry 2022Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 µm x 0.4 mm ChromXP C18-CL chip, 3 µm, 120 Å, SCIEX) and washed at 2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Microbiology 2022Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 μm x 0.4 mm ChromXP C18-CL chip, 3 μm, 120 Å, SCIEX) and washed at 2 μl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Molecular Biology 2022Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 µm x 0.4 mm ChromXP C18-CL chip, 3 µm, 120 Å, SCIEX) and washed at 1-2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Neuroscience 2021Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 µm x 0.4 mm ChromXP C18-CL chip, 3 µm, 120 Å, SCIEX) and washed at 2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Neuroscience 2023Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 µm x 0.4 mm ChromXP C18-CL chip, 3 µm, 120 Å, SCIEX) and washed at 2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Neuroscience 2023Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 µm x 0.4 mm ChromXP C18-CL chip, 3 µm, 120 Å, SCIEX) and washed at 2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Cell Biology 2021Quote: ... peptide mixtures were transferred onto a trap chip (with 200 μm x 6 mm ChromXP C18-CL chip, 3 μm, 300 Å, SCIEX) and washed at 2 μL/min for 10 min with the loading solvent (H2O/0.1% formic acid) ...
-
bioRxiv - Neuroscience 2022Quote: ... peptide mixtures were transferred onto a C18 pre-column chip (200 μm × 6 mm ChromXP C18-CL chip, 3 μm, 300 Å; SCIEX) and washed at 2 μL/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Immunology 2019Quote: ... peptide mixtures were transferred onto a C18 pre-column chip (200 μm x 6 mm ChromXP C18-CL chip, 3 μm, 300 Å, SCIEX) and washed at 2 μl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Cell Biology 2019Quote: ... peptide mixtures were transferred onto a C18 pre-column chip (200 µm x 6 mm ChromXP C18-CL chip, 3 µm, 300 Å, SCIEX) and washed at 2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Cancer Biology 2022Quote: ... Proteolytic peptides were loaded onto a C18 pre-column chip (200 μm × 6 mm ChromXP C18-CL chip, 3 μm, 300 Å; SCIEX) and washed at 2 μL/minute for 10 minutes with the loading solvent (H2O/0.1% FA ...
-
bioRxiv - Cancer Biology 2023Quote: ... Proteolytic peptides were loaded onto a C18 pre-column chip (200 μm × 6 mm ChromXP C18-CL chip, 3 μm, 300 Å; SCIEX) and washed at 2 μL/minute for 10 minutes with the loading solvent (0.1% FA in H2O ...
-
bioRxiv - Microbiology 2021Quote: ... the samples were analyzed on a TripleTOF5600 mass spectrometer coupled to an NanoLC-2DPlus ChiP system (Sciex). For the analysis involving the rpsAΔ56 mutant missing the last two C-terminal OB fold domains of protein S1 ...
-
bioRxiv - Developmental Biology 2020Quote: ... Peptides were separated for 60 min using a 15 cm chip column (ChromXP C18, 3 μm, 120 Å) (SCIEX) with an acetonitrile gradient from 3-35% ...
-
bioRxiv - Neuroscience 2023Quote: ... peptides were transferred to the 75 µm x 15 cm ChromXP C18-CL chip (3 µm, 120 Å; SCIEX), and eluted at a flow rate of 300 nL/min with a 3 h gradient using aqueous and acetonitrile solvent buffers.
-
bioRxiv - Genomics 2023Quote: ... and the corresponding chemical kit (SCIEX). The peak scoring was done with the provided software (GenomeLab ...
-
bioRxiv - Microbiology 2019Quote: ... using the Big Dye terminator cycling ready reaction kit version 3.1 or GenomeLab DTCS Quick Start Kit (SCIEX, Framingham, MA).
-
bioRxiv - Neuroscience 2019Quote: ... The iTRAQ Reagent 4plex Kit (Sciex, Cat#4352135) was used to label the tryptic peptides derived from the different SM fractions as follows ...
-
bioRxiv - Plant Biology 2020Quote: ... using the GenomeLab DTCS Quick Start Kit (SCIEX). The sequence-verified plasmids were introduced into Agrobacterium tumefaciens strain GV3101 [41] ...
-
bioRxiv - Plant Biology 2023Quote: ... a standard (MS synthetic peptide calibration kit from Sciex) was injected to self-calibrate the equipment ...
-
bioRxiv - Microbiology 2019Quote: ... using the GenomeLab DTCS Quick Start Kit (SCIEX, Framingham, MA).
-
bioRxiv - Genetics 2019Quote: ... and labeled using the 8-plex iTRAQ Labeling Kit (AB Sciex). The fractionation of iTRAQ-multiplex labeled peptide mixture was carried out using Agilent AdvanceBio Column (2.7 μm ...
-
bioRxiv - Physiology 2021Quote: ... The Lipidyzer™ Platform was tuned using the SelexION Tuning Kit (SCIEX) according to the manufacturer’s recommendations and a system suitability test was performed using the System Suitability Kit (SCIEX ...
-
bioRxiv - Immunology 2023Quote: ... a 10 kDa MW internal standard (SDS-MW kit, AB SciEx LLC) was added ...
-
bioRxiv - Microbiology 2024Quote: ... Mass calibration was performed with a peptide mass standards kit (AB SCIEX) or with a purified and structurally characterized LPS sample from Bordetella pertussis.
-
bioRxiv - Cancer Biology 2020Quote: ... using the aTRAQ kit for amino acid analysis of physio-logical fluids (Sciex). Acquisition in the mass spectrometer was achieved by multiple reaction monitoring ...
-
bioRxiv - Immunology 2019Quote: ... lyophilised and labelled using mTRAQ labelling kit (Δ0 and Δ8 Da; AB-Sciex) for phagosomal samples.
-
bioRxiv - Biochemistry 2021Quote: ... Mass spectra were deconvoluted using Bio Tool Kit in PeakView 2.2 software (Sciex).
-
bioRxiv - Physiology 2022Quote: ... 50 µL of internal standard solution (Lipidyzer internal standard kit, [cat# 5040156, Sciex, Redwood City ...
-
bioRxiv - Immunology 2023Quote: ... Differential Mobility Device on Lipidyzer was tuned with SelexION tuning kit (Sciex 5040141). Instrument settings ...
-
bioRxiv - Microbiology 2020Quote: ... Samples were labeled with iTRAQ Reagent-8 plex Multiplex Kit (AB Sciex U.K. Limited) according to the manufacturer instructions ...
-
bioRxiv - Cancer Biology 2019Quote: ... K562 cell digests were obtained from the SWATH Performance Kit (SCIEX, Framingham, MA, USA). iRT peptides (Biognosys ...
-
bioRxiv - Microbiology 2020Quote: ... In each replicate the samples were labelled with an iTRAQ 4 plex kit (Sciex) as follows ...
-
bioRxiv - Physiology 2022Quote: ... Differential Mobility Device on the Lipidyzer was tuned with SelexION tuning kit (Sciex, 5040141). The instrument settings ...
-
Mammalian-unique eIF4E2 maintains GSK3β proline kinase activity to resist senescence against hypoxiabioRxiv - Cell Biology 2020Quote: ... the peptides were labeled with iTRAQ Reagent-8 plex Multiplex Kit (AB Sciex U.K. Limited) according to the manufacturer’s protocol ...
-
bioRxiv - Physiology 2021Quote: ... Digested peptides were recovered and labelled using two 8-plex iTRAQ kits (SCIEX, Framingham, MA) according to manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2022Quote: ... and cysteine blocking reagent from the iTRAQ Reagents Multiplex kit (AB Sciex, Framingham, MA, USA). Subsequently ...
-
bioRxiv - Molecular Biology 2022Quote: ... the peptides were labeled according to the instructions of the iTRAQ kit (AB SCIEX, US), and the labeled peptides were loaded onto the Agilent 300Extend C18 column (5 μm particle diameter ...
-
bioRxiv - Biochemistry 2022Quote: ... Samples are then diluted with the Sciex IgG Purity/Heterogeneity kit sample buffer (Sciex, MA, USA) and beta-mercaptoethanol (BME ...
-
bioRxiv - Systems Biology 2023Quote: ... Isotopically labelled lipid standards were obtained from the LipidyzerTM Internal Standards Kit from SCIEX (MA, USA), and SPLASH LipidoMIXTM internal standards ...
-
bioRxiv - Microbiology 2022Quote: ... iTRAQ reagent labeling was performed according to the 8-plex iTRAQ kit instructions (AB SCIEX, Framingham, MA).
-
bioRxiv - Neuroscience 2022Quote: ... the samples were labeled following the manufacturer’s instructions for the iTRAQ Reagents 8-plex kit (AB Sciex). Samples were each labeled with iTRAQ reagents with molecular masses of 113 ...
-
bioRxiv - Physiology 2021Quote: ... according to the manufacturer’s recommendations and a system suitability test was performed using the System Suitability Kit (SCIEX) according to the manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2022Quote: ... iTRAQ labeling of the peptides in each sample was performed using the iTRAQ Reagents Multiplex kit (AB Sciex). A large amount of Ca2+ for tryptic digestion was removed using a cation exchange buffer pack (AB Sciex ...
-
bioRxiv - Biochemistry 2021Quote: ... The instrument was calibrated using mono- and multi-charged ions of BSA (BSA Calibration Standard Kit, AB SCIEX, France). HSulf-2ΔSG was desalted as previously described (Seffouh et al. ...
-
bioRxiv - Cancer Biology 2023Quote: The panel of amino acids was quantified based on aTRAQ kit for amino acid analysis (SCIEX, Framingham, MA, USA) and liquid chromatography coupled to a triple quadrupole tandem mass spectrometry technique ...
-
Molecular Basis of Sex Difference in Neuroprotection induced by Hypoxia Preconditioning in ZebrafishbioRxiv - Neuroscience 2020Quote: Prior to trypsin digestion all the protein samples were gone through reduction and cysteine blocking using the reagents provided with iTRAQ 4-plex kit (AB SCIEX). Digestion and labelling of proteins were done according to manufacturer’s protocol ...
-
bioRxiv - Neuroscience 2021Quote: ... The resultant peptides were further labeled using isobaric tags for relative and absolute quantification (iTRAQ) 4-plex commercial reagent kit (AB Sciex) according to the manufacturer’s instructions ...
-
bioRxiv - Immunology 2023Quote: ... 1 mL) and loaded onto a pre-equilibrated SCX column ICAT™ cartridge kit (Applied Biosystems-AB Sciex, USA, #4326752). The peptides were eluted using different concentrations (30 ...