Labshake search
Citations for Quantifoil Micro Tools :
1 - 50 of 315 citations for Histone H3 mono methyl R2 Rabbit Recombinant mAb since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: R2/2 grids (Quantifoil) were covered with a thin layer of continuous carbon (estimated to be 50 Å thick ...
-
bioRxiv - Cell Biology 2021Quote: Gold grids (Quantifoil, R2/2) were glow-discharged and incubated on top of 40 μL droplets of fibronectin (50 μg/mL ...
-
bioRxiv - Molecular Biology 2021Quote: ... Cu R2/1 grids (Quantifoil) were plasma cleaned using a NanoClean plasma cleaner (Fischione Instruments ...
-
bioRxiv - Immunology 2021Quote: Quantifoil finder grids (R2/1 or R2/2, Au 200 mesh grid, Quantifoil Micro Tools, Germany) were glow discharged with a 30 mA current for 30 s using Edwards Sputter Coater (S150B) ...
-
bioRxiv - Biophysics 2022Quote: ... R2/2 Cu 300 grids (Quantifoil) were glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device ...
-
bioRxiv - Microbiology 2020Quote: ... or Quantifoil R2/2 (Quantifoil, Germany). The samples were cryo-fixed by plunge freezing at −180°C in liquid ethane using a Leica EMGP (Leica ...
-
bioRxiv - Microbiology 2022Quote: ... we used R2/2 grids (Quantifoil) coated with a thin layer of 0.2 mg/ml graphene oxide ...
-
bioRxiv - Neuroscience 2020Quote: Holey carbon grids (Quantifoil R2/1) covered with either 2 nm amorphous carbon (Quantifoil ...
-
bioRxiv - Microbiology 2022Quote: ... Quantifoil (R2/2, Quantifoil Micro Tools) Au-EM finder grids ...
-
bioRxiv - Biochemistry 2023Quote: Quantifoil Cu200 R2/2 grids (Quantifoil) were pre-clipped and marked along the clip edge to determine the orientation in the future ...
-
Cryo-electron tomography of eel sperm flagella reveals a molecular “minimum system” for motile ciliabioRxiv - Cell Biology 2023Quote: ... holey carbon grids (Quantifoil R2/2) were glow discharged for 30 seconds in a Pelco EasyGlow glow discharge unit ...
-
bioRxiv - Biophysics 2023Quote: EM grids (UltrAuFoil R2/2 Au 200 mesh Q250AR2A and Quantifoil R2/2 Au 200 mesh Q2100AR2) were micropatterned using the Alveole PRIMO micropatterning system20–22 ...
-
bioRxiv - Microbiology 2022Quote: ... using R2/2 200 mesh grids (Quantifoil) and imaged using a Talos 120 kV cryo-transmission electron microscope.
-
bioRxiv - Biochemistry 2023Quote: UltrAuFoil R2/2 Au200 mesh grids (Quantifoil) were glow discharged for 1 min on both sides at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Biochemistry 2023Quote: UltrAuFoil R2/2 Au300 mesh grids (Quantifoil) were glow discharged for 30 seconds on each side at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Microbiology 2023Quote: R2/2 Cu 200 mesh grids (Quantifoil) were glow-discharged for 40 s at 2.7 mA ...
-
bioRxiv - Microbiology 2022Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically blotted from the backside for 4-6 s in a Mark IV Vitrobot by using a Teflon sheet on the front pad ...
-
bioRxiv - Microbiology 2023Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically backside blotted for 4-6s in a Mark IV Vitrobot (Thermo Fischer Scientific ...
-
bioRxiv - Biochemistry 2023Quote: ... pristine graphene-coated R2/4 grids (Graphenea) were initially used for optimisation purposes but 2 nm formvar/amorphous carbon R2/2 grids (Quantifoil) were used for data collection ...
-
bioRxiv - Biophysics 2020Quote: Holey carbon grids (Quantifoil R2/1, 200 mesh) were plasma treated using a Solarus plasma cleaner (Gatan) ...
-
bioRxiv - Biochemistry 2022Quote: R2/2 holey carbon supported copper grids (Quantifoil) coated with a 2nm thin carbon layer were treated as described (A ...
-
bioRxiv - Biochemistry 2020Quote: ... QF AU-200 mesh R2/2 grids (Quantifoil) were glow-discharged and placed into a 6-well tissue culture plate well containing 2 mL of cell culture medium for at least 1 h before cell seeding ...
-
bioRxiv - Plant Biology 2021Quote: Holey carbon grids (Quantifoil R2/1, 200 mesh) were plasma cleaned using a Solarus plasma cleaner (Gatan) ...
-
bioRxiv - Molecular Biology 2022Quote: ... The no carbon sample (Quantifoil Cu200 R2/1) was blotted for 1.5 s from the back side right after sample application and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Microbiology 2022Quote: ... gold finder grids (Au NH2 R2/2, Quantifoil) containing infected amoebae were vitrified by back-blotting (Teflon ...
-
bioRxiv - Cell Biology 2023Quote: ... 200 mesh R2/1 Au EM grids (Quantifoil) were coated with laminin (1:10 dilution ...
-
bioRxiv - Biochemistry 2023Quote: ... UltrAufoil Au 200 mesh R2/2 grids (Quantifoil) EM grids were glow-discharged on each side for 90 s at 30 sccm ...
-
bioRxiv - Microbiology 2023Quote: CryoEM samples were prepared by applying 5 μL aliquots of purified PLE PLPs to R2/2 Quantifoil grids and R2/2 Quantifoil grids coated with 2nm ultrathin Carbon (QUANTIFOIL®) that had been glow discharged for 45 seconds in a Pelco Easiglow glow discharging unit ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a Mark IV Vitrobot(Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: ... holey carbon grids (Quantifoil R2/1 200 mesh copper) for 1 min ...
-
bioRxiv - Biophysics 2019Quote: ... perforated carbon copper grid (Quantifoil R2/1 200 mesh). The nuclei were opened manually and the nuclear envelopes spread over the grid ...
-
bioRxiv - Cell Biology 2021Quote: Holey carbon grids (Quantifoil R2/1, 200 mesh, gold) were washed in acetone while agitating on a rocker for 15 to 30 min to remove potential residual plastic backing ...
-
bioRxiv - Microbiology 2021Quote: EM grids (G300F1, R2/2 Quantifoil holey carbon, gold) were glow-discharged and treated with bovine fibronectin (20 μg/ml ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a Mark IV Vitrobot maintained at room temperature and 70% humidity ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a FEI Mark IV Vitrobot maintained at room temperature and 70% humidity ...
-
bioRxiv - Cell Biology 2021Quote: Carbon-coated gold TEM grids (Quantifoil NH2A R2/2) were glow-discharged at 2 mA and 1.5–1.8 × 10-1 m bar for 1 min in an ELMO (Cordouan ...
-
bioRxiv - Biochemistry 2022Quote: UltrAuFoil on gold 200 mesh R2/2 grids (Quantifoil) were subjected to micropatterning using the Primo module from Alveole mounted on a Leica DMi8 microscope following the manufacturer procedure ...
-
bioRxiv - Microbiology 2022Quote: ... loaded onto glow discharged carbon grids (R2/2, Quantifoil) and plunge-frozen using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Cell Biology 2023Quote: Carbon-coated gold TEM grids (Quantifoil NH2A R2/2) were glow-discharged at 2 mA and 1.5– × 10−1 m bar for 1 minute in an ELMO (Cordouan ...
-
bioRxiv - Biochemistry 2023Quote: ... R2/1 holey carbon without amorphous carbon from Quantifoil. 3 µL of a 2.5 µM solution was applied to the grid ...
-
bioRxiv - Biophysics 2024Quote: ... Holey carbon grids (Quantifoil Cu 300 mesh, R2/2) were prepared with fiducials by glow-discharging ...
-
bioRxiv - Biochemistry 2024Quote: ... Quantifoil Cu 200 R2/2 holey carbon grids (Quantifoil) were glow discharged negatively for 45 sec before sample application ...
-
bioRxiv - Biophysics 2021Quote: To provide extra support for cell growth 5-6 nm of carbon was evaporated onto Quantifoil Au 200 R2/1 or R2/2 grids (Quantifoil Micro Tools GmbH). Grids were then glow discharged and incubated in supplemented RPMI-1640 overnight in the cell incubator ...
-
bioRxiv - Biophysics 2023Quote: Three microliters of the purified GLV-HP or GLV-CAT sample was placed on a glow-discharged holey carbon grid (Quantifoil R2/2 or R2/1, Cu 300 mesh; Quantifoil Micro Tools GmbH) for 3 s blotting time at 4°C ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then seeded onto gold grids (either ‘UltrAuFoil’ 200 Au mesh, R2/2 gold film, or Quantifoil 300 Au mesh, R2/2 carbon film (Quantifoil Micro Tools, Großlöbichau, Germany) and grown to 50 % confluency before plunge freezing ...
-
bioRxiv - Biochemistry 2020Quote: ... Holey carbon supported copper-grids (Quantifoil R2/1 300 mesh) were plasma-cleaned for 30 s (Harrick Plasma ...
-
bioRxiv - Microbiology 2020Quote: Glow-discharged carbon-coated gold TEM grids (Quantifoil R2/1) were seeded with 33,000 MA104 cells and allowed to adhere for 4 hours at 37°C ...
-
bioRxiv - Microbiology 2020Quote: ... Quantifoil Cu R2/2 Finder grids (Quantifoil Micro Tools GmbH) were glow-discharged at 15mA for 1min ...
-
bioRxiv - Biophysics 2020Quote: UltrAuFoil R2/2 200 mesh TEM grids (Quantifoil Micro Tools) were prepared by 200 second glow discharge in 0.39 mBar of room air using a Pelco easiGlow (Ted Pella) ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were pipetted onto Quantifoil Cu R2/1 grids (Quantifoil), blotted for ∼4 s and plunge frozen using a manual plunger ...